An experimental study on the hydrodynamic performance of the water-wall system of a 600 MW supercritical CFB boiler

被引:22
|
作者
Chen, Ye [1 ]
Lu, Xiaofeng [1 ]
Zhang, Wenqing [2 ]
Wang, Quanhai [1 ]
Chen, Sida [1 ]
Fan, Xuchen [1 ]
Li, Jianbo [1 ]
机构
[1] Chongqing Univ, Minist Educ, Key Lab Low Grade Energy Utilizat Technol & Syst, Chongqing 400044, Peoples R China
[2] Sichuan Baima CFB Demonstrat Power Plant Co Ltd, Neijiang 641005, Sichuan, Peoples R China
关键词
Mass flux; Metal temperature; Supercritical CFB boiler; Thermal-hydrodynamic performance; THERMAL-HYDRAULIC CALCULATION; HEAT-TRANSFER; FLUIDIZED-BED; FUZZY-LOGIC; TUBES; FLUX; RECIRCULATION; COMBUSTION; FURNACE;
D O I
10.1016/j.applthermaleng.2018.01.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
The temperature distribution on the backside of the water-wall tubes in the first 600 MW CFB boiler operating at 60%, 80% and 100% of the boiler Maximum Continuous Rating (MCR) loads was experimentally determined and the thermal-hydrodynamic performance of water-wall system based on the mass and energy equations using the measured temperature was calculated. The results showed that the temperature of the water-wall tubes increased as the furnace height increased, showing a positive response characteristic in the water-wall system. However, the temperature of the water-wall tubes in the upper furnace was obviously declined at the places where the superheaters and cyclone separator inlet-channels were arranged. This suggests that the arrangement of the heat-transfer surfaces in the upper furnace was significantly influenced the temperature distribution of the water-wall tubes. Meanwhile, the calculated total pressure-drop and mass flux in the water-wall system increased as the boiler's load raised, showing an energy-efficiency for the vertical once-through boiler. In addition, the metal temperature was calculated to check the working condition of the water-wall tubes and the results showed the highest metal temperature of 426.3 degrees C of the water-wall tubes was found at the tip of the fin at 100% MCR. This temperature was far below the permissible temperature of the metal, implying that a safe working condition of the metal at three loads was guaranteed. Nonetheless, analysis into the heat-transfer characteristics of the water in the water-wall reflects that the water temperature in the water-wall at 80% MCR load was adjacent to the boundary of the large specific-heat region, implying that heat-transfer deterioration was more likely to occur at such condition. Therefore, the metal temperature of the water-wall tubes operating at 80% MCR load requires the most concern and monitor to avoid overheating of the water-wall tubes.
引用
收藏
页码:280 / 287
页数:8
相关论文
共 50 条
  • [1] Thermal-hydraulic calculation and analysis on water wall system of 600 MW supercritical CFB boiler
    Pan, Jie
    Wu, Gang
    Yang, Dong
    APPLIED THERMAL ENGINEERING, 2015, 82 : 225 - 236
  • [2] Heat transfer characteristic of water wall and partition wall in a 600 MW CFB boiler
    Cheng, L. (lemingc@zju.edu.cn), 1600, Chinese Society for Electrical Engineering (34):
  • [3] Experimental and numerical study on air flow uniformity in the isobaric windbox of a 600 MW supercritical CFB boiler
    Yan, Jin
    Lu, Xiaofeng
    Wang, Quanhai
    Kang, Yinhu
    Li, Jianbo
    Zhou, Jinliang
    Zhang, Yi
    Lv, Zhuo
    Sun, Sicong
    APPLIED THERMAL ENGINEERING, 2017, 122 : 311 - 321
  • [4] Research Of The Fins Thickness Based On 600MW Supercritical Boiler Water-wall Cross-Section Temperature Distribution
    Su, Yongjun
    Yang, Junbao
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 384 - 389
  • [5] Independent Research and Design of 600-MW Supercritical CFB Boiler
    Sun Xianbin
    Electricity, 2010, 21 (02) : 36 - 40
  • [6] High-temperature Corrosion of Water-wall in Supercritical Boiler
    Pan, Ling
    Ma, Guangyuan
    Cao, Shunan
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY AND ENVIRONMENTAL SCIENCE 2015, 2015, 31 : 1342 - 1346
  • [7] Operation characteristics of external heat exchangers in the 600 MW supercritical CFB boiler
    Cai, Runxia
    Zhang, Man
    Mo, Xin
    Lyu, Junfu
    Yang, Hairui
    Lei, Xiujian
    Ling, Wen
    Su, Hu
    Zhou, Qi
    FUEL PROCESSING TECHNOLOGY, 2018, 172 : 65 - 71
  • [8] ANALYSIS OF TEMPERATURE DROPS ON THE WALL THICKNESS OF A SUPERCRITICAL BOILER WATER-WALL TUBE
    Zima, Wieslaw
    THERMAL SCIENCE, 2019, 23 : S1091 - S1100
  • [9] A non-equal fragment model of a water-wall in a supercritical boiler
    Wang, Jizhou
    Zhang, Yanping
    Li, Yu
    Huang, Shuhong
    JOURNAL OF THE ENERGY INSTITUTE, 2015, 88 (02) : 143 - 150
  • [10] Safety analysis on the water wall in the 350 MW supercritical CFB boiler under sudden electricity failure
    Deng, Boyu
    Zhang, Man
    Lyu, Junfu
    Li, Shaohua
    Yang, Hairui
    ENERGY, 2019, 189