An experimental study on the hydrodynamic performance of the water-wall system of a 600 MW supercritical CFB boiler

被引:22
|
作者
Chen, Ye [1 ]
Lu, Xiaofeng [1 ]
Zhang, Wenqing [2 ]
Wang, Quanhai [1 ]
Chen, Sida [1 ]
Fan, Xuchen [1 ]
Li, Jianbo [1 ]
机构
[1] Chongqing Univ, Minist Educ, Key Lab Low Grade Energy Utilizat Technol & Syst, Chongqing 400044, Peoples R China
[2] Sichuan Baima CFB Demonstrat Power Plant Co Ltd, Neijiang 641005, Sichuan, Peoples R China
关键词
Mass flux; Metal temperature; Supercritical CFB boiler; Thermal-hydrodynamic performance; THERMAL-HYDRAULIC CALCULATION; HEAT-TRANSFER; FLUIDIZED-BED; FUZZY-LOGIC; TUBES; FLUX; RECIRCULATION; COMBUSTION; FURNACE;
D O I
10.1016/j.applthermaleng.2018.01.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
The temperature distribution on the backside of the water-wall tubes in the first 600 MW CFB boiler operating at 60%, 80% and 100% of the boiler Maximum Continuous Rating (MCR) loads was experimentally determined and the thermal-hydrodynamic performance of water-wall system based on the mass and energy equations using the measured temperature was calculated. The results showed that the temperature of the water-wall tubes increased as the furnace height increased, showing a positive response characteristic in the water-wall system. However, the temperature of the water-wall tubes in the upper furnace was obviously declined at the places where the superheaters and cyclone separator inlet-channels were arranged. This suggests that the arrangement of the heat-transfer surfaces in the upper furnace was significantly influenced the temperature distribution of the water-wall tubes. Meanwhile, the calculated total pressure-drop and mass flux in the water-wall system increased as the boiler's load raised, showing an energy-efficiency for the vertical once-through boiler. In addition, the metal temperature was calculated to check the working condition of the water-wall tubes and the results showed the highest metal temperature of 426.3 degrees C of the water-wall tubes was found at the tip of the fin at 100% MCR. This temperature was far below the permissible temperature of the metal, implying that a safe working condition of the metal at three loads was guaranteed. Nonetheless, analysis into the heat-transfer characteristics of the water in the water-wall reflects that the water temperature in the water-wall at 80% MCR load was adjacent to the boundary of the large specific-heat region, implying that heat-transfer deterioration was more likely to occur at such condition. Therefore, the metal temperature of the water-wall tubes operating at 80% MCR load requires the most concern and monitor to avoid overheating of the water-wall tubes.
引用
收藏
页码:280 / 287
页数:8
相关论文
共 50 条
  • [41] Numerical Simulation and Experimental Investigation of Gas-solid Flow Uniformity in a 600MW CFB Boiler
    Liu M.
    Lu X.
    Wang Q.
    Xu J.
    Yan J.
    Xu Z.
    Zhou S.
    Lei X.
    Liu C.
    Xie X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (02): : 543 - 549
  • [42] Gas-Solid Hydrodynamics and Combustion Characteristics in a 600 MW Annular CFB Boiler for Supercritical CO2 Cycles
    Cui, Ying
    Zhong, Wenqi
    Liu, Xuejiao
    Xiang, Jun
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2020, 59 (50) : 21617 - 21629
  • [43] Numerical analysis on the flow instability of parallel channels in water wall of an ultra-supercritical CFB boiler
    Xie, Beibei
    Yang, Dong
    Wang, Wenyu
    Nie, Xin
    Liu, Wanyu
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 110 : 545 - 554
  • [44] Heat transfer and frictional resistance characteristics of the water wall tube of an ultra-supercritical CFB boiler
    Wang, Wenyu
    Yang, Dong
    Jiang, Huiqing
    Qu, Mofeng
    Zhao, Yunjie
    JOURNAL OF SUPERCRITICAL FLUIDS, 2017, 128 : 279 - 290
  • [45] Investigation on Hydrodynamic Performance and Wall Temperature of Water-Cooled Wall in 1000 MW Boiler Under Low-Load Conditions
    Chong, Peian
    Zhu, Xiaolei
    Li, Jianning
    Li, Xiao
    Deng, Lei
    ENERGIES, 2024, 17 (22)
  • [46] Analysis and Referential Significance of a Breakdown Accident of the Main Feed Water Pump in a 350 MW Supercritical CFB Boiler
    Boyu Deng
    Man Zhang
    Guohua Wei
    Junfu Lyu
    Hairui Yang
    Journal of Thermal Science, 2023, 32 : 1797 - 1806
  • [47] Analysis and Referential Significance of a Breakdown Accident of the Main Feed Water Pump in a 350 MW Supercritical CFB Boiler
    DENG Boyu
    ZHANG Man
    WEI Guohua
    LYU Junfu
    YANG Hairui
    Journal of Thermal Science, 2023, 32 (05) : 1797 - 1806
  • [48] Analysis and Referential Significance of a Breakdown Accident of the Main Feed Water Pump in a 350 MW Supercritical CFB Boiler
    Deng, Boyu
    Zhang, Man
    Wei, Guohua
    Lyu, Junfu
    Yang, Hairui
    JOURNAL OF THERMAL SCIENCE, 2023, 32 (05) : 1797 - 1806
  • [50] Arc spraying technology for water-cooling wall of CFB boiler and performance of coating
    Zhang, Xiao-Hui
    Liu, Zheng
    Shenyang Gongye Daxue Xuebao/Journal of Shenyang University of Technology, 2009, 31 (04): : 392 - 396