An experimental study on the hydrodynamic performance of the water-wall system of a 600 MW supercritical CFB boiler

被引:22
|
作者
Chen, Ye [1 ]
Lu, Xiaofeng [1 ]
Zhang, Wenqing [2 ]
Wang, Quanhai [1 ]
Chen, Sida [1 ]
Fan, Xuchen [1 ]
Li, Jianbo [1 ]
机构
[1] Chongqing Univ, Minist Educ, Key Lab Low Grade Energy Utilizat Technol & Syst, Chongqing 400044, Peoples R China
[2] Sichuan Baima CFB Demonstrat Power Plant Co Ltd, Neijiang 641005, Sichuan, Peoples R China
关键词
Mass flux; Metal temperature; Supercritical CFB boiler; Thermal-hydrodynamic performance; THERMAL-HYDRAULIC CALCULATION; HEAT-TRANSFER; FLUIDIZED-BED; FUZZY-LOGIC; TUBES; FLUX; RECIRCULATION; COMBUSTION; FURNACE;
D O I
10.1016/j.applthermaleng.2018.01.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
The temperature distribution on the backside of the water-wall tubes in the first 600 MW CFB boiler operating at 60%, 80% and 100% of the boiler Maximum Continuous Rating (MCR) loads was experimentally determined and the thermal-hydrodynamic performance of water-wall system based on the mass and energy equations using the measured temperature was calculated. The results showed that the temperature of the water-wall tubes increased as the furnace height increased, showing a positive response characteristic in the water-wall system. However, the temperature of the water-wall tubes in the upper furnace was obviously declined at the places where the superheaters and cyclone separator inlet-channels were arranged. This suggests that the arrangement of the heat-transfer surfaces in the upper furnace was significantly influenced the temperature distribution of the water-wall tubes. Meanwhile, the calculated total pressure-drop and mass flux in the water-wall system increased as the boiler's load raised, showing an energy-efficiency for the vertical once-through boiler. In addition, the metal temperature was calculated to check the working condition of the water-wall tubes and the results showed the highest metal temperature of 426.3 degrees C of the water-wall tubes was found at the tip of the fin at 100% MCR. This temperature was far below the permissible temperature of the metal, implying that a safe working condition of the metal at three loads was guaranteed. Nonetheless, analysis into the heat-transfer characteristics of the water in the water-wall reflects that the water temperature in the water-wall at 80% MCR load was adjacent to the boundary of the large specific-heat region, implying that heat-transfer deterioration was more likely to occur at such condition. Therefore, the metal temperature of the water-wall tubes operating at 80% MCR load requires the most concern and monitor to avoid overheating of the water-wall tubes.
引用
收藏
页码:280 / 287
页数:8
相关论文
共 50 条
  • [31] Numerical analysis of flow instability in the water wall of a supercritical CFB boiler with annular furnace
    Beibei Xie
    Dong Yang
    Haiyan Xie
    Xin Nie
    Wanyu Liu
    Journal of Thermal Science, 2016, 25 : 372 - 379
  • [32] Experimental Study on the Heat-Transfer Characteristics of a 600 MW Supercritical Circulating Fluidized Bed Boiler
    Chen, Ye
    Lu, Xiaofeng
    Zhang, Wenqing
    Wang, Quanhai
    Chen, Sida
    Xu, Jie
    Yang, Yu
    Li, Jianbo
    ENERGY & FUELS, 2018, 32 (01) : 1 - 9
  • [33] A hybrid simulation of a 600 MW supercritical circulating fluidized bed boiler system
    Wu, Haochuang
    Yang, Chen
    He, Hangxing
    Huang, Shanglong
    Chen, Hao
    APPLIED THERMAL ENGINEERING, 2018, 143 : 977 - 987
  • [34] The Experimental Investigation on Flow and Heat Transfer Characteristics of the Rifled Water Wall Tube of an Ultra-supercritical CFB Boiler
    Wang W.
    Li Y.
    Zhao Y.
    Qu M.
    Yang D.
    Ling W.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2018, 38 (02): : 373 - 382
  • [35] Experimental study and safety analysis on the heating surfaces in the 660 MW supercritical CFB boiler under sudden electricity failure
    Li, Yinlong
    Xie, Beibei
    Bi, Lingfeng
    Yang, Haoyu
    Nie, Chao
    Qing, Hao
    Yang, Dong
    ENERGY SCIENCE & ENGINEERING, 2022, 10 (07) : 2088 - 2105
  • [36] Experimental study and safety analysis on the heating surfaces in the 660 MW supercritical CFB boiler under sudden electricity failure
    Li, Yinlong
    Xie, Beibei
    Bi, Lingfeng
    Yang, Haoyu
    Nie, Chao
    Qing, Hao
    Yang, Dong
    Energy Science and Engineering, 2022, 10 (07): : 2088 - 2105
  • [37] Study on the dynamic characteristics of a 600 MW supercritical once-through boiler
    Fan, Yongsheng
    Cheng, Fanzhen
    Sui, Zhe
    Lu, Chongde
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2000, 40 (10): : 104 - 107
  • [38] Thermal-Hydraulic Calculation and Analysis on Water Wall System of a 700 MWe Ultra-Supercritical CFB Boiler
    Wu, Haowen
    Zhou, Tuo
    Hu, Xiannan
    Luo, Yongjun
    Zhang, Man
    Yang, Hairui
    ENERGIES, 2023, 16 (11)
  • [39] The Numerical Calculation of the Temperature Field of Water-wall Tube of the Supercritical Boiler under Near-Critical Condition
    Li Chun-yan
    MATERIALS RESEARCH AND APPLICATIONS, PTS 1-3, 2014, 875-877 : 1876 - 1880
  • [40] A comprehensive understanding of the non-uniform characteristics and regulation mechanism of six external loops in a 600 MW supercritical CFB boiler
    Yan, Jin
    Lu, Xiaofeng
    Song, Yangfan
    Zheng, Xiong
    Lei, Xiujian
    Liu, Zhuo
    Fan, Xuchen
    Liu, Congcong
    ENERGY, 2021, 222