Analysis on Boiler Main Protection Logic of 600 MW Supercritical Unit

被引:0
|
作者
Pan Jin-jie [1 ]
Liu You-kuan [2 ]
Tian Pei [3 ]
机构
[1] Univ North China, Elect Power Co, Yunnan Power Grid Graduateworkstn, Kun Ming 650217, Peoples R China
[2] Yunnan Power Grid Power Res Inst, Kun Ming 650217, Peoples R China
[3] Univ North China, Elect Power, Grad Sch Automat, Baoding 071000, Peoples R China
关键词
FSSS; MFT; W-shape flame boiler; 600 MW supercritical unit;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper introduces the function of Furnace Safeguard Supervisory System (FSSS) for the power plant of huadian zhenxiong of 600 MW supercritical unit of W-shape flame boiler. Proceeding detailed analysis for the trip on the boiler main fuel trip logical, and the investment conditions in the operation process. This is providing the reference for the same type boiler main protection function.
引用
收藏
页码:132 / 136
页数:5
相关论文
共 50 条
  • [41] Simulation Investigation on the Dynamic Characteristics of a 600MW Supercritical Lignite-Fired Pulverized Boiler
    Han, Xiaoqu
    Xue, Zhaonan
    Liu, Ming
    Yan, Junjie
    Wang, Jinshi
    Chong, Daotong
    Liu, Jiping
    INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 : 1434 - 1437
  • [43] HEAT FLUXES ON WATERWALLS IN A 300 MW UNIT SUPERCRITICAL BOILER WITH AN OPEN FURNACE AND GAS RECIRCULATION
    BELYAKOV, II
    KRASYAKO.LY
    THERMAL ENGINEERING, 1973, 19 (05) : 26 - 30
  • [44] RESEARCH AND DESIGN OF 1000 MW ULTRA-SUPERCRITICAL UNIT BOILER FEED PUMP TURBINE
    Zhang, Yuanlin
    Pan, Jiacheng
    Zhang, Jian
    Zhang, Qiong
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON POWER ENGINEERING 2009 (ICOPE-09), VOL 3, 2009, : 359 - 364
  • [45] Boiler flashing for unit protection
    Mallard, RE
    Jenkins, WR
    Palmer, RD
    PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 59 - PTS I AND II, 1997, 59 : 597 - 599
  • [46] Boiler flashing for unit protection
    Mallard, RE
    Jenkins, WR
    Palmer, RD
    PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 59, I AND II, 1997, 59 : 597 - 599
  • [47] Subspace Method based Dynamic Model Identification of the 600MW supercritical once-through boiler
    Wang Yinsong
    Kong Zihua
    Liu Hao
    SYSTEMS, ORGANIZATIONS AND MANAGEMENT: PROCEEDINGS OF THE 3RD WORKSHOP OF INTERNATIONAL SOCIETY IN SCIENTIFIC INVENTIONS, 2009, : 287 - 294
  • [48] Performance of the primary air concentrators on anthracite ignition and combustion in a 600 MW supercritical arch-fired boiler
    Liu, Pengyuan
    Gao, Jiajia
    Zhang, Hai
    Zhang, Dalong
    Wu, Yuxin
    Zhang, Man
    Lu, Junfu
    FUEL PROCESSING TECHNOLOGY, 2017, 158 : 172 - 179
  • [49] Testing and research on stage combustion of 600 MW boiler
    Harbin Jianzhu Daxue Xuebao/Journal of Harbin University of Civil Engineering and Architecture, 31 (04): : 3 - 9
  • [50] Basic design studies for a 600 MW CFB boiler
    Bursi, J.M.
    Lafanechère, L.
    Jestin, L.
    VGB PowerTech, 2000, 80 (02): : 35 - 44