Modeling of an air cooler with finned heat transfer tube banks using the RELAP5-3D code

被引:5
|
作者
Mochizuki, Hiroyasu [1 ]
机构
[1] Tokyo Inst Technol, Inst Innovat Res, Lab Adv Nucl Energy, Meguro Ku, 2-12-1 Ookayama, Tokyo 1528550, Japan
关键词
REACTOR;
D O I
10.1016/j.nucengdes.2020.110902
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The present paper proposes a calculation model of an air cooler using the RELAP5-3D code. Up to now, the modeling of an air cooler using RELAP5-3D was not described in detail, and there was a problem when calculating the decay heat removal system with the air cooler. Above all, the study of the heat transfer model for an air cooler with finned heat transfer tube banks is few. Since a decay heat removal system with air coolers is essential in liquid metal cooled fast nuclear reactors, it is anticipated how to model the air cooler using implemented heat transfer models in the RELAP5-3D code. The finned heat transfer tube is simulated with multiple bare tubes which have the equivalent heat transfer characteristics considering fin efficiency. Two kinds of simulations have been compared to the measured results of the "Monju" reactor under the forced and natural convection conditions in order to confirm the applicability of the proposed model. The simulation result under the forced convection condition is in good agreement with the test result except the operation mode under the natural convection. Since the simulation result under the natural convection condition overpredicts the test result, the surface area is lessened in order to decrease the heat transfer. As a result, good agreement has been obtained between the simulation and the test result under the natural convection condition. Sensitivity analysis has been performed for the cases where the outside diameter and the number of the simulated heat transfer tubes, and number of divisions of the calculation meshes are changed. It has been confirmed that there is almost no change in the total heat transfer rate even if various diameter tubes are used and the number of divisions is changed. The number of heat transfer tubes has a non-linear sensitivity to the removal heat rate.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] RELAP5-3D ANALYSIS OF EBR-II SHUTDOWN HEAT REMOVAL TEST SHRT-17
    De Luca, Domenico
    Petruzzi, Alessandro
    Cherubini, Marco
    Parrinello, Valeria
    PROCEEDINGS OF THE 24TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2016, VOL 3, 2016,
  • [42] The 3-D Numerical Simulation of Heat Transfer Process of Finned Copper Tube
    Zhong, Jianhua
    Jiang, Liming
    Feng, Kai
    BIOTECHNOLOGY, CHEMICAL AND MATERIALS ENGINEERING, PTS 1-3, 2012, 393-395 : 412 - +
  • [43] Heat transfer augmentation in 3D internally finned and microfinned helical tube
    Li, LJ
    Cui, WZ
    Liao, Q
    Xin, MD
    Jen, TC
    Chen, QH
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (10) : 1916 - 1925
  • [44] Investigation of the effect of using the finned tubes on the performance of shell and tube heat exchanger by 3D modeling
    Maghsoudali, Yasin
    Rastegarkoutenaei, Ali
    Sahami, Masoud
    Bandpy, Mofid Gorji
    JOURNAL OF ENERGY STORAGE, 2022, 56
  • [45] Flow and heat transfer characteristics of finned tube with internal and external fins in air cooler for waste heat recovery of gas-fired boiler system
    Liu, Lin
    Fan, Yuezhong
    Ling, Xiang
    Peng, Hao
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2013, 74 : 142 - 152
  • [46] A quick measurement method of heat transfer coefficient and friction factor for finned tube bundle of the air cooler under large temperature difference
    Wu, Yongyong
    Liu, Yang
    Zhang, Zhen
    Xiang, Qun
    Sun, Yanfei
    Yang, Xingtuan
    Jiang, Shengyao
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 227
  • [47] RELAP5-3D modeling of PWR steam generator condensation experiments at the Oregon State University APEX facility
    Woods, Brian G.
    Collins, Brian
    NUCLEAR ENGINEERING AND DESIGN, 2009, 239 (10) : 1925 - 1932
  • [48] Validation of coupled neutronic/thermal-hydraulic code RELAP5-3D for RBMK-1500 reactor analysis application
    Uspuras, E
    Kaliatka, A
    Bubelis, E
    ANNALS OF NUCLEAR ENERGY, 2004, 31 (15) : 1667 - 1708
  • [49] Modelling of a supercritical CO2 power cycle for nuclear fusion reactors using RELAP5-3D
    Batet, L.
    Alvarez-Fernandez, J. M.
    Mas de Les Valls, E.
    Martinez-Quiroga, V.
    Perez, M.
    Reventos, F.
    Sedano, L. A.
    FUSION ENGINEERING AND DESIGN, 2014, 89 (04) : 354 - 359
  • [50] Preliminary neutron kinetic - thermal hydraulic coupled analysis of the ALFRED reactor using PHISICS/RELAP5-3D
    Ciurluini, Cristiano
    Narcisi, Vincenzo
    Giannetti, Fabio
    Cretara, Luca
    Caruso, Gianfranco
    37TH UIT HEAT TRANSFER CONFERENCE, 2020, 1599