A quick measurement method of heat transfer coefficient and friction factor for finned tube bundle of the air cooler under large temperature difference

被引:3
|
作者
Wu, Yongyong [1 ]
Liu, Yang [1 ]
Zhang, Zhen [1 ]
Xiang, Qun [1 ]
Sun, Yanfei [1 ]
Yang, Xingtuan [1 ]
Jiang, Shengyao [1 ]
机构
[1] Tsinghua Univ, Collaborat Innovat Ctr Adv Nucl Energy Technol, Key Lab Adv Reactor Engn & Safety, Inst Nucl & New Energy Technol,Minist Educ, Beijing 100084, Peoples R China
关键词
Annular finned tube; Heat transfer coefficient; Friction factor; Passive decay heat removal; Natural circulation; SMALL MODULAR REACTOR; REMOVAL SYSTEM; PRESSURE-DROP; PERFORMANCE; EXCHANGERS; FLOW;
D O I
10.1016/j.ijheatmasstransfer.2024.125556
中图分类号
O414.1 [热力学];
学科分类号
摘要
The annular finned tube bundle of air cooler serves as an essential heat exchanger to perform passive decay heat removal from the reactor core to the ultimate heat sink in the NHR200-II small modular nuclear reactors. The performance of heat transfer and flow resistance is crucial for nuclear safety as a finned tube bundle operates under natural circulation involving a significant temperature difference between the inlet and outlet. Therefore, a new quick method of experimental measurement is proposed in this article to determine and verify the heat transfer coefficient and friction factor of the finned tube bundle, and the theoretical true mean temperature difference is established from the exact energy conservation relation. The new measurement method is universal to various tube bundle types, eliminating the need for time-consuming preparation of steady heat state and expensive devices of high-pressure and high-temperature water. Additionally, it allows for the acquisition of abundant data within a relatively short period. This work has conducted 131 tests across an extensive variety of Reynolds numbers (Re: 1176 - 4813), Prandtl numbers, inlet temperatures, and powers to verify the applicability of the empirical correlations used in design. Furthermore, this article proposes a suitable empirical correlation of heat transfer coefficient based on experimental data for the crucial natural circulation range (Re: 1176 - 2500). Considering the large inlet-outlet temperature differences in natural circulation range, a new empirical correlation of friction factor is provided to address the limitations of existing correlations derived under isothermal conditions. This quick measurement method shows excellent agreement with the classic Briggs-Young correlation within a valid range, confirming its correctness and accuracy.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Effect of heat transfer direction on a friction factor in the air cross flow to finned tube bundle
    Walczyk, H
    Rotkegel, A
    INZYNIERIA CHEMICZNA I PROCESOWA, 2002, 23 (02): : 219 - 227
  • [2] Friction factor and Reynolds number correlation for finned tube bundle of the air cooler of Monju reactor
    Sotsu, Masutake
    NUCLEAR ENGINEERING AND DESIGN, 2022, 396
  • [3] The effect of heat transfer direction on the heat transfer coefficient in the air cross flow to the finned tube bundle
    Walczyk, H
    Rotkegel, A
    INZYNIERIA CHEMICZNA I PROCESOWA, 2001, 22 (3E): : 1429 - 1434
  • [4] Air side heat transfer coefficient in plate finned tube heat exchangers
    Mihailovic, Milos
    Milovancevic, Uros
    Genic, Srbislav
    Jacimovic, Branislav
    Otovic, Milena
    Kolendic, Petar
    EXPERIMENTAL HEAT TRANSFER, 2020, 33 (04) : 388 - 399
  • [5] Prediction and measurement of apparent heat transfer coefficient by condensation in finned-tube heat exchangers
    Bougriou, Cherif
    Bessaih, Rachid
    HEAT TRANSFER ENGINEERING, 2007, 28 (11) : 940 - 953
  • [6] ESTIMATION OF TOTAL HEAT-TRANSFER COEFFICIENT OF AN AIR COOLER WITH FINNED TUBING - CASE OF PETROLEUM CUTS
    DRONEAU, B
    REVUE GENERALE DE THERMIQUE, 1975, 14 (158): : 115 - 134
  • [7] HEAT AND MASS TRANSFER AND RESISTANCE CHARACTERISTICS OF EVAPORATIVE AIR COOLER WITH HIGH FINNED-TUBE BUNDLES
    Zhang, Qing
    Wang, Xuesheng
    Ruan, Weicheng
    Chen, Qinzhu
    Liu, Zilong
    HEAT TRANSFER RESEARCH, 2018, 49 (17) : 1705 - 1720
  • [8] Numerical investigation on air-side heat transfer enhancement of wavy finned tube air cooler for underground tunnels
    Wang, Yangjie
    Cai, Tianqi
    Niu, Pengxiang
    Fan, Wenbo
    Wang, Yijiang
    APPLIED THERMAL ENGINEERING, 2025, 269
  • [9] In-situ evaluation of heat transfer and friction factor in the entrance area of finned tube banks
    Nir, A.
    Proceedings of the World Conference on Experimental Heat Transfer, Fluid Mechanics, and Thermodynamics, 1991,
  • [10] EXPERIMENTAL STUDY ON NATURAL CONVECTION HEAT TRANSFER OUTSIDE TUBE BUNDLE IN SPACE UNDER LOW TEMPERATURE DIFFERENCE
    Xu, Junxiu
    Ding, Ming
    Yan, Changqi
    Fan, Guangming
    PROCEEDINGS OF THE 2020 INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING (ICONE2020), VOL 3, 2020,