A quick measurement method of heat transfer coefficient and friction factor for finned tube bundle of the air cooler under large temperature difference

被引:3
|
作者
Wu, Yongyong [1 ]
Liu, Yang [1 ]
Zhang, Zhen [1 ]
Xiang, Qun [1 ]
Sun, Yanfei [1 ]
Yang, Xingtuan [1 ]
Jiang, Shengyao [1 ]
机构
[1] Tsinghua Univ, Collaborat Innovat Ctr Adv Nucl Energy Technol, Key Lab Adv Reactor Engn & Safety, Inst Nucl & New Energy Technol,Minist Educ, Beijing 100084, Peoples R China
关键词
Annular finned tube; Heat transfer coefficient; Friction factor; Passive decay heat removal; Natural circulation; SMALL MODULAR REACTOR; REMOVAL SYSTEM; PRESSURE-DROP; PERFORMANCE; EXCHANGERS; FLOW;
D O I
10.1016/j.ijheatmasstransfer.2024.125556
中图分类号
O414.1 [热力学];
学科分类号
摘要
The annular finned tube bundle of air cooler serves as an essential heat exchanger to perform passive decay heat removal from the reactor core to the ultimate heat sink in the NHR200-II small modular nuclear reactors. The performance of heat transfer and flow resistance is crucial for nuclear safety as a finned tube bundle operates under natural circulation involving a significant temperature difference between the inlet and outlet. Therefore, a new quick method of experimental measurement is proposed in this article to determine and verify the heat transfer coefficient and friction factor of the finned tube bundle, and the theoretical true mean temperature difference is established from the exact energy conservation relation. The new measurement method is universal to various tube bundle types, eliminating the need for time-consuming preparation of steady heat state and expensive devices of high-pressure and high-temperature water. Additionally, it allows for the acquisition of abundant data within a relatively short period. This work has conducted 131 tests across an extensive variety of Reynolds numbers (Re: 1176 - 4813), Prandtl numbers, inlet temperatures, and powers to verify the applicability of the empirical correlations used in design. Furthermore, this article proposes a suitable empirical correlation of heat transfer coefficient based on experimental data for the crucial natural circulation range (Re: 1176 - 2500). Considering the large inlet-outlet temperature differences in natural circulation range, a new empirical correlation of friction factor is provided to address the limitations of existing correlations derived under isothermal conditions. This quick measurement method shows excellent agreement with the classic Briggs-Young correlation within a valid range, confirming its correctness and accuracy.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Prediction of heat transfer coefficient and friction factor of mini channel shell and tube heat exchanger using numerical analysis and experimental validation
    Unverdi, Murat
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2022, 171
  • [42] LOCAL HEAT-TRANSFER RATE AT A TUBE IN A CORRIDOR BUNDLE LATERAL TO AN AIR STREAM AT LARGE REYNOLDS-NUMBERS
    POSHKAS, PS
    SURVILA, VY
    ZHUKAUSKAS, AA
    INTERNATIONAL CHEMICAL ENGINEERING, 1978, 18 (02): : 337 - 343
  • [43] Fin Pattern Effects on Air-Side Heat Transfer and Friction Characteristics of Fin-and-Tube Heat Exchangers with Large Number of Large-Diameter Tube Rows
    Tang, Ling-Hong
    Min, Zeng
    Xie, Gong-Nan
    Wang, Qiu-Wang
    HEAT TRANSFER ENGINEERING, 2009, 30 (03) : 171 - 180
  • [44] Analysis of Heat Transfer Characteristics of Natural Convection Condensation of Steam Containing Air under Different Tube Bundle Arrangements
    Liu, Le
    Chen, Wenzhen
    Wang, Jue
    Wang, Cong
    Hu, Chen
    Hedongli Gongcheng/Nuclear Power Engineering, 2022, 43 (03): : 94 - 100
  • [45] Quick identification of gases for enhancing heat transfer in turbulent pipe flows using standard correlation equations for the convective coefficient and the friction factor
    Campo, A
    APPLIED THERMAL ENGINEERING, 2005, 25 (13) : 2029 - 2038
  • [46] Studies on heat transfer and friction factor characteristics of turbulent flow through a micro-finned tube fitted with left-right inserts
    Nagarajan, P. K.
    Mukkamala, Yagna
    Sivashanmugam, P.
    APPLIED THERMAL ENGINEERING, 2010, 30 (13) : 1666 - 1672
  • [47] Measurement of subcooled boiling pressure drop and local heat transfer coefficient in horizontal tube under LPLF conditions
    Baburajan, P. K.
    Bisht, G. S.
    Gupta, S. K.
    Prabhu, S. V.
    NUCLEAR ENGINEERING AND DESIGN, 2013, 255 : 169 - 179
  • [48] Measurement of local wall temperature and heat flux using the two-thermocouple method for a heat transfer tube
    Ahn, Taehwan
    Kang, Jinhoon
    Jeong, Jae Jun
    Yun, Byongjo
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2019, 51 (07) : 1853 - 1859
  • [49] Comparison of convective heat transfer coefficient and friction factor of TiO2 nanofluid flow in a tube with twisted tape inserts
    Azmi, W. H.
    Sharma, K. V.
    Sarma, P. K.
    Mamat, Rizalman
    Anuar, Shahrani
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2014, 81 : 84 - 93
  • [50] Parametric study and multiple correlations on air-side heat transfer and friction characteristics of fin-and-tube heat exchangers with large number of large-diameter tube rows
    Xie, Gongnan
    Wang, Qiuwang
    Sunden, Bengt
    APPLIED THERMAL ENGINEERING, 2009, 29 (01) : 1 - 16