A quick measurement method of heat transfer coefficient and friction factor for finned tube bundle of the air cooler under large temperature difference

被引:3
|
作者
Wu, Yongyong [1 ]
Liu, Yang [1 ]
Zhang, Zhen [1 ]
Xiang, Qun [1 ]
Sun, Yanfei [1 ]
Yang, Xingtuan [1 ]
Jiang, Shengyao [1 ]
机构
[1] Tsinghua Univ, Collaborat Innovat Ctr Adv Nucl Energy Technol, Key Lab Adv Reactor Engn & Safety, Inst Nucl & New Energy Technol,Minist Educ, Beijing 100084, Peoples R China
关键词
Annular finned tube; Heat transfer coefficient; Friction factor; Passive decay heat removal; Natural circulation; SMALL MODULAR REACTOR; REMOVAL SYSTEM; PRESSURE-DROP; PERFORMANCE; EXCHANGERS; FLOW;
D O I
10.1016/j.ijheatmasstransfer.2024.125556
中图分类号
O414.1 [热力学];
学科分类号
摘要
The annular finned tube bundle of air cooler serves as an essential heat exchanger to perform passive decay heat removal from the reactor core to the ultimate heat sink in the NHR200-II small modular nuclear reactors. The performance of heat transfer and flow resistance is crucial for nuclear safety as a finned tube bundle operates under natural circulation involving a significant temperature difference between the inlet and outlet. Therefore, a new quick method of experimental measurement is proposed in this article to determine and verify the heat transfer coefficient and friction factor of the finned tube bundle, and the theoretical true mean temperature difference is established from the exact energy conservation relation. The new measurement method is universal to various tube bundle types, eliminating the need for time-consuming preparation of steady heat state and expensive devices of high-pressure and high-temperature water. Additionally, it allows for the acquisition of abundant data within a relatively short period. This work has conducted 131 tests across an extensive variety of Reynolds numbers (Re: 1176 - 4813), Prandtl numbers, inlet temperatures, and powers to verify the applicability of the empirical correlations used in design. Furthermore, this article proposes a suitable empirical correlation of heat transfer coefficient based on experimental data for the crucial natural circulation range (Re: 1176 - 2500). Considering the large inlet-outlet temperature differences in natural circulation range, a new empirical correlation of friction factor is provided to address the limitations of existing correlations derived under isothermal conditions. This quick measurement method shows excellent agreement with the classic Briggs-Young correlation within a valid range, confirming its correctness and accuracy.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Numerical study on heat transfer and pressure drop characteristics of plain-finned tube under high temperature
    Ma, Ting
    Zeng, Min
    Xie, Gong-Nan
    Wang, Qiu-Wang
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2010, 31 (09): : 1571 - 1574
  • [32] Heat transfer characteristics of cryogenic helium gas through a miniature tube with a large temperature difference
    Jiao, AJ
    Jeong, S
    Ma, HB
    CRYOGENICS, 2004, 44 (12) : 859 - 866
  • [33] Advancements in analyzing air-side heat transfer coefficient on the individual tube rows in finned heat exchangers: Comparative study of three CFD methods
    Marcinkowski, Mateusz
    Taler, Dawid
    Weglarz, Katarzyna
    Taler, Jan
    ENERGY, 2024, 307
  • [34] A Numerical Method on Inverse Determination of Heat Transfer Coefficient Based on Thermographic Temperature Measurement
    Fan Chunli
    Sun Fengrui
    Yang Li
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2008, 16 (06) : 901 - 908
  • [35] Optimization of Air-side Friction and Heat Transfer Performance of Micro-bare-tube Heat Exchangers With Bundle Diameters Varying Gradually
    Gong, Zhenguo
    Zhou, Wenjie
    Cai, Bowen
    Wang, Xin
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2025, 46 (01): : 57 - 67
  • [36] Measurement of Heat Transfer Coefficient of Magnesium Alloy and Temperature Change of Roll using Heat Transfer Solidification Analysis Method
    Han, Chang-Suk
    Lee, Chan-Woo
    KOREAN JOURNAL OF MATERIALS RESEARCH, 2022, 32 (09): : 391 - 395
  • [37] Effect of large temperature difference on impingement heat transfer under a round turbulent jet
    Shi, YL
    Mujumdar, AS
    Ray, MB
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2004, 31 (02) : 251 - 260
  • [38] Experimental verification and improvement of heat transfer tube local wall temperature measurement method
    Liu, Jiabao
    Cao, Xiaxin
    Yang, Peixun
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (12) : 4317 - 4328
  • [39] Effective heat transfer coefficient measurement during air impingement thawing using an inverse method
    Anderson, BA
    Singh, RP
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (02): : 281 - 293
  • [40] Comparison of Individual Air-Side Row-By-Row Heat Transfer Coefficient Correlations on Four-Row Finned-Tube Heat Exchangers
    Marcinkowski, Mateusz
    Taler, Dawid
    Taler, Jan
    HEAT TRANSFER ENGINEERING, 2023, 44 (11-12) : 1002 - 1014