Modeling of an air cooler with finned heat transfer tube banks using the RELAP5-3D code

被引:5
|
作者
Mochizuki, Hiroyasu [1 ]
机构
[1] Tokyo Inst Technol, Inst Innovat Res, Lab Adv Nucl Energy, Meguro Ku, 2-12-1 Ookayama, Tokyo 1528550, Japan
关键词
REACTOR;
D O I
10.1016/j.nucengdes.2020.110902
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The present paper proposes a calculation model of an air cooler using the RELAP5-3D code. Up to now, the modeling of an air cooler using RELAP5-3D was not described in detail, and there was a problem when calculating the decay heat removal system with the air cooler. Above all, the study of the heat transfer model for an air cooler with finned heat transfer tube banks is few. Since a decay heat removal system with air coolers is essential in liquid metal cooled fast nuclear reactors, it is anticipated how to model the air cooler using implemented heat transfer models in the RELAP5-3D code. The finned heat transfer tube is simulated with multiple bare tubes which have the equivalent heat transfer characteristics considering fin efficiency. Two kinds of simulations have been compared to the measured results of the "Monju" reactor under the forced and natural convection conditions in order to confirm the applicability of the proposed model. The simulation result under the forced convection condition is in good agreement with the test result except the operation mode under the natural convection. Since the simulation result under the natural convection condition overpredicts the test result, the surface area is lessened in order to decrease the heat transfer. As a result, good agreement has been obtained between the simulation and the test result under the natural convection condition. Sensitivity analysis has been performed for the cases where the outside diameter and the number of the simulated heat transfer tubes, and number of divisions of the calculation meshes are changed. It has been confirmed that there is almost no change in the total heat transfer rate even if various diameter tubes are used and the number of divisions is changed. The number of heat transfer tubes has a non-linear sensitivity to the removal heat rate.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Neutronics and thermal-hydraulics coupling analysis using the FLUENT code and the RELAP5-3D code for a molten salt fast reactor
    Mochizuki, Hiroyasu
    NUCLEAR ENGINEERING AND DESIGN, 2020, 368
  • [22] BEPU analysis of a passive decay heat removal system with RELAP5/ MOD3.3 and RELAP5-3D
    Alcaro, Fabio
    Bersano, Andrea
    Bertani, Cristina
    Mascari, Fulvio
    PROGRESS IN NUCLEAR ENERGY, 2021, 136
  • [23] Verification of RELAP5-3D code in natural circulation loop as function of the initial water inventory
    Bertani, C.
    Falcone, N.
    Bersano, A.
    Caramello, M.
    Matsushita, T.
    De Salve, M.
    Panella, B.
    35TH UIT HEAT TRANSFER CONFERENCE (UIT2017), 2017, 923
  • [24] RELAP5-3D multidimensional heat conduction enclosure model for RBMK reactor application
    Paik, SH
    NUCLEAR TECHNOLOGY, 1999, 128 (01) : 87 - 102
  • [25] BWR Station Blackout: A RISMC Analysis Using RAVEN and RELAP5-3D
    Mandelli, D.
    Smith, C.
    Riley, T.
    Nielsen, J.
    Alfonsi, A.
    Cogliati, J.
    Rabiti, C.
    Schroeder, J.
    NUCLEAR TECHNOLOGY, 2016, 193 (01) : 161 - 174
  • [26] Thermal-hydraulic system study of the HELOKA-LP helium loop using RELAP5-3D code
    Jin, Xue Zhou
    Schlindwein, Georg
    Schlenker, Markus
    Ghidersa, Bradut-Eugen
    Chen, Yuming
    Arbeiter, Frederik
    FUSION ENGINEERING AND DESIGN, 2013, 88 (9-10) : 2560 - 2564
  • [27] Modeling of Finned-Tube Heat Exchanger Using in Air Conditioning System
    Khotphan, Suphod
    SURANAREE JOURNAL OF SCIENCE AND TECHNOLOGY, 2006, 13 (01): : 20 - 28
  • [28] Uncertainty quantification method for RELAP5-3D© using RAVEN and application on NACIE experiments
    Narcisi, Vincenzo
    Lorusso, Pierdomenico
    Giannetti, Fabio
    Alfonsi, Andrea
    Caruso, Gianfranco
    ANNALS OF NUCLEAR ENERGY, 2019, 127 : 419 - 432
  • [29] Thermal-hydraulic system study of a high pressure, high temperature helium loop using RELAP5-3D code
    Jin, Xue Zhou
    Ghidersa, Bradut-Eugen
    NUCLEAR ENGINEERING AND DESIGN, 2012, 249 : 57 - 62
  • [30] Validation of neutronics and thermal-hydraulics coupling model of the RELAP5-3D code using the MSRE reactivity insertion tests
    Mochizuki, Hiroyasu
    NUCLEAR ENGINEERING AND DESIGN, 2022, 389