Bipolar Radiofrequency Ablation: Development of a New Expandable Device

被引:4
|
作者
Ito, Nobutake [1 ,2 ]
Pfeffer, Jochen [1 ]
Isfort, Peter [1 ,2 ]
Penzkofer, Tobias [1 ,2 ]
Kuhl, Christiane K. [1 ]
Mahnken, Andreas H. [3 ]
Schmitz-Rode, Thomas [2 ]
Bruners, Philipp [1 ]
机构
[1] Rhein Westfal TH Aachen, Dept Diagnost Radiol, Aachen, Germany
[2] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, Aachen, Germany
[3] Univ Marburg, Dept Radiol, Marburg, Germany
关键词
Liver; Minimally invasive therapy; Radiofrequency ablation; INTERNALLY COOLED ELECTRODES; ENHANCED HEPATIC BIPOLAR; VIVO BOVINE LIVER; EFFICIENCY; MONOPOLAR; TUMORS; COMPLICATIONS; APPLICATORS; COAGULATION; PRINCIPLES;
D O I
10.1007/s00270-013-0703-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To test the performance of an expandable bipolar probe as a simple technical solution for extending the coagulation volume. On the basis of a commercially available monopolar radiofrequency (RF) probe (LeVeen), an expandable bipolar RF probe was developed by integrating a second electrode into the probe shaft. The influence of length on the second electrode, and the distance between both electrodes and generator output was investigated by performing ten ablations for each condition on a freshly excised bovine liver. Macroscopically quantified coagulation volumes, lesion shape characteristics, and procedure durations were recorded. Results of the prototype featuring the optimal configuration were compared to the original LeVeen probe and commonly used bipolar RF probe (CelonLabPower). Extension of the shaft electrode length, increasing distance between the shaft electrode and the tip electrode, and reduction of generator output resulted in increasing coagulation volumes. The coagulation volumes the prototype generated were significantly smaller and more elliptically shaped than the monopolar probe (9.4 +/- A 1.5 cm(3) vs. 12.1 +/- A 1.6 cm(3)), but were larger than the commercially available bipolar RF probe (vs. 7.3 +/- A 0.5). The procedure duration of the prototype was comparable to the monopolar probe (467 +/- A 31 s vs. 464 +/- A 17 s) and shorter than the bipolar probe (vs. 2009 +/- A 444 s). In comparison to the commercially available bipolar system, the developed prototype exhibited favorable results. The first benchmark testing of the developed bipolar prototype had promising results. However, further optimization of the applicator design and ablation protocol is needed to enlarge the achievable coagulation volume.
引用
收藏
页码:770 / 776
页数:7
相关论文
共 50 条
  • [41] Hepatic ablation using bipolar radiofrequency electrocautery
    McGahan, JP
    Gu, WZ
    Brock, JM
    Tesluk, H
    Jones, CD
    ACADEMIC RADIOLOGY, 1996, 3 (05) : 418 - 422
  • [42] Sepsis After Bipolar Radiofrequency Endometrial Ablation
    Salmeen, Kirsten
    Morgan, Daniel
    OBSTETRICS AND GYNECOLOGY, 2009, 114 (02): : 445 - 448
  • [43] Bipolar Radiofrequency Catheter Ablation for Ventricular Arrhythmias
    Nakajima, Kenzaburo
    Zweiker, David
    Spartalis, Michael
    Zachariah, Donah
    Limite, Luca
    Peretto, Giovanni
    Frontera, Antonio
    Della Bella, Paolo
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2022, 23 (05)
  • [44] Randomized controlled trial of a new procedure of radiofrequency ablation using an expandable needle for hepatocellular carcinoma
    Hirakawa, Miharu
    Ikeda, Kenji
    Kobayashi, Masahiro
    Kawamura, Yusuke
    Hosaka, Tetsuya
    Sezaki, Hitomi
    Akuta, Norio
    Suzuki, Fumitaka
    Suzuki, Yoshiyuki
    Saitoh, Satoshi
    Arase, Yasuji
    Kumada, Hiromitsu
    HEPATOLOGY RESEARCH, 2013, 43 (08) : 846 - 852
  • [45] Radiofrequency Bipolar Surgical Ablation for Atrial Fibrillation
    Patwardhan, Anil
    ANNALS OF THORACIC SURGERY, 2018, 105 (02): : 667 - +
  • [46] Radiofrequency ablation of prostate using bipolar technology
    Woo, H.
    BJU INTERNATIONAL, 2006, 97 : 27 - 27
  • [47] NEW BIPOLAR AND UNIPOLAR CRITERIA FOR SUCCESSFUL RADIOFREQUENCY ABLATION OF CONCEALED ACCESSORY PATHWAYS
    MEDINA, O
    VILLACASTIN, J
    ALMENDRAL, J
    ARENAL, A
    MARTINEZALDAY, J
    PASTOR, A
    PEINADO, R
    ORMAETXE, J
    DELCAN, JL
    CIRCULATION, 1993, 88 (04) : 63 - 63
  • [48] Ablation of Bull Prostate Using Novel Bipolar Radiofrequency Ablation Probe
    Richstone, Lee
    Ziegelbaum, Matt
    Okeke, Zeph
    Faure, Andre
    Kaye, Jonathan D.
    Sette, Marcelo J.
    Reggio, Ernesto
    Ost, Michael
    Kavoussi, Louis R.
    Lee, Benjamin R.
    JOURNAL OF ENDOUROLOGY, 2009, 23 (01) : 11 - 16
  • [49] Efficacy of a novel bipolar radiofrequency ablation device on the beating heart for atrial fibrillation ablation: A long-term porcine study
    Voeller, Rochus K.
    Zierer, Andreas
    Lall, Shelly C.
    Sakamoto, Shun-ichiro
    Schuessler, Richard B.
    Damiano, Ralph J., Jr.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (01): : 203 - 208
  • [50] Evaluation of a bipolar-cooled radiofrequency device for ablation of bone metastases: preclinical assessment in porcine vertebrae
    Pezeshki, Padina S.
    Woo, Jason
    Akens, Margarete K.
    Davies, John E.
    Gofeld, Michael
    Whyne, Cari M.
    Yee, Albert J. M.
    SPINE JOURNAL, 2014, 14 (02): : 361 - 370