Chemiluminescence microflow injection analysis system on a chip for the determination of nitrite in food

被引:88
|
作者
He, Deyong [1 ]
Zhang, Zhujun [1 ]
Huang, Ying [1 ]
Hu, Yufei [1 ]
机构
[1] SW Normal Univ, Inst Analyt Sci, Key Lab Analyt Chem Chongqing, Chongqing 400715, Peoples R China
关键词
microflow injection analysis; chemiluminescence; nitrite; chip;
D O I
10.1016/j.foodchem.2006.02.024
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A new microflow injection analysis (mu FIA) system on a chip for the determination of nitrite is described. The chip is produced by using two transparent poly(methylmethacrylate) (PMMA) slices measured 50 x 40 x 5 mm, and the microchannels etched by CO2 laser are 200 mu m wide and 100 mu m deep with the volume of reaction area about 1.8 mu L. Nitrite is sensed by the chemiluminescence (CL) reaction of luminol with ferricyanide that is the product of the reaction of ferrocyanide with nitrite in acidic medium. The syringe pump with an accurate timer controls all reagents, including the sample. The linear range of the nitrite concentration is 8-100 mu g L-1 and the detection limit is 4 mu g L-1 (S/N = 3). The proposed method has good reproducibility with the relative standard deviation 4.1% for 50 mu g L-1 of nitrite (n = 9) and is very sensitive and simple. It has been successfully applied to. the determination of nitrite in food. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:667 / 672
页数:6
相关论文
共 50 条
  • [31] Determination of dipyridamole by flow injection analysis with chemiluminescence detection
    Yang, ML
    Li, LQ
    Feng, ML
    Lü, JR
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (02) : 161 - 163
  • [33] Rapid flow injection analysis method for successive determination of ammonia, nitrite, and nitrate in water by gas-phase chemiluminescence
    Aoki, T
    Fukuda, S
    Hosoi, Y
    Mukai, H
    ANALYTICA CHIMICA ACTA, 1997, 349 (1-3) : 11 - 16
  • [34] Automatic injection analysis with chemiluminescence detection: Determination of hydrazine
    He, ZK
    Liu, XL
    Luo, QY
    Tang, HW
    Yu, XM
    Chen, H
    Zeng, YE
    MICROCHEMICAL JOURNAL, 1996, 53 (03) : 356 - 360
  • [35] Determination of hydroxycamptothecinum by flow injection analysis with chemiluminescence detection
    Li Liqing
    Lin, Guan
    Ming, Su
    Sun Hanwen
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2007, 21 (06) : 356 - 362
  • [36] Determination of isoniazid by flow-injection chemiluminescence analysis
    Qu, P
    Li, BX
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (05) : 665 - 667
  • [37] Determination of norfloxacin by flow injection analysis with chemiluminescence detection
    Sun, Han-wen
    Li, Li-qing
    Chen, Xue-yan
    Shi, Hong-mei
    Lue, Yun-kai
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2006, 51 (02): : 100 - 107
  • [38] Ethanol determination by the flow injection analysis, with chemiluminescence detection
    Danet, AF
    Badea, M
    Jipa, S
    REVISTA DE CHIMIE, 1997, 48 (08): : 726 - 731
  • [39] Determination of riboflavin by flow injection analysis with chemiluminescence detection
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao, 5 Suppl (354):
  • [40] Flow-Injection Analysis Method for the Determination of Nitrite and Nitrate in Natural Water Samples Using a Chemiluminescence NOx Monitor
    Yukio Kanda
    Masafumi Taira
    Analytical Sciences, 2003, 19 : 695 - 699