Chemiluminescence microflow injection analysis system on a chip for the determination of nitrite in food

被引:88
|
作者
He, Deyong [1 ]
Zhang, Zhujun [1 ]
Huang, Ying [1 ]
Hu, Yufei [1 ]
机构
[1] SW Normal Univ, Inst Analyt Sci, Key Lab Analyt Chem Chongqing, Chongqing 400715, Peoples R China
关键词
microflow injection analysis; chemiluminescence; nitrite; chip;
D O I
10.1016/j.foodchem.2006.02.024
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A new microflow injection analysis (mu FIA) system on a chip for the determination of nitrite is described. The chip is produced by using two transparent poly(methylmethacrylate) (PMMA) slices measured 50 x 40 x 5 mm, and the microchannels etched by CO2 laser are 200 mu m wide and 100 mu m deep with the volume of reaction area about 1.8 mu L. Nitrite is sensed by the chemiluminescence (CL) reaction of luminol with ferricyanide that is the product of the reaction of ferrocyanide with nitrite in acidic medium. The syringe pump with an accurate timer controls all reagents, including the sample. The linear range of the nitrite concentration is 8-100 mu g L-1 and the detection limit is 4 mu g L-1 (S/N = 3). The proposed method has good reproducibility with the relative standard deviation 4.1% for 50 mu g L-1 of nitrite (n = 9) and is very sensitive and simple. It has been successfully applied to. the determination of nitrite in food. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:667 / 672
页数:6
相关论文
共 50 条
  • [41] Flow-injection analysis method for the determination of nitrite and nitrate in natural water samples using a chemiluminescence NOx monitor
    Kanda, Y
    Taira, M
    ANALYTICAL SCIENCES, 2003, 19 (05) : 695 - 699
  • [42] Application of chemiluminescence involving flow injection analysis to determination of glucose, glutamic acid and lactic acid for food analysis
    Wang, Xing
    Ishii, Naoko
    Ye, Ming
    Munkhjargal, Munkhbayar
    Miyajima, Kumiko
    Arakawa, Takahiro
    Saito, Hirokazu
    Kudo, Hiroyuki
    Endo, Hideaki
    Mitsubayashi, Kohji
    2013 IEEE SENSORS, 2013, : 999 - 1002
  • [43] Chemiluminescence system for automatic determination of chemical oxygen demand using flow injection analysis
    Li, BX
    Zhang, ZJ
    Wang, J
    Xu, CL
    TALANTA, 2003, 61 (05) : 651 - 658
  • [44] SIMULTANEOUS FLOW-INJECTION DETERMINATION OF NITRATE AND NITRITE IN WATER BY GAS-PHASE CHEMILUMINESCENCE
    AOKI, T
    WAKABAYASHI, M
    ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) : 308 - 312
  • [45] DETERMINATION OF NITRITE BY REVERSE FLOW-INJECTION ANALYSIS
    VINAS, P
    CORDOBA, MH
    SANCHEZPEDRENO, C
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1988, 32 (3-4) : 279 - 289
  • [46] Spectrophotometric determination of nitrite in foodstuffs by flow injection analysis
    VanStaden, JF
    Makhafola, MA
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 356 (01): : 70 - 74
  • [47] A RAPID METHOD FOR THE DETERMINATION OF NITRATE AND NITRITE BY CHEMILUMINESCENCE
    WALTERS, CL
    GILLATT, PN
    PALMER, RC
    SMITH, PLR
    FOOD ADDITIVES AND CONTAMINANTS, 1987, 4 (02): : 133 - 140
  • [48] A novel flow-injection chemiluminescence system for the determination of guanine
    Yang, M
    Liu, R
    Hou, DY
    Guo, YY
    LUMINESCENCE, 2005, 20 (4-5) : 307 - 310
  • [49] Rapid determination of isoamyl nitrite in pharmaceutical preparations by flow injection analysis with on-line UV irradiation and luminol chemiluminescence detection
    Kishikawa, Naoya
    Kondo, Naoko
    Amponsaa-Karikari, Abena
    Kodamatani, Hitoshi
    Ohyama, Kaname
    Nakashima, Kenichiro
    Yamazaki, Shigeo
    Kuroda, Naotaka
    LUMINESCENCE, 2014, 29 (01) : 8 - 12
  • [50] Direct Determination of Lead and Cadmium in Distilled Spirits by Inductively Coupled Plasma Mass Spectrometry Coupled with Chip-based Microflow Injection System
    Hao Li
    Cheng He-Yong
    Liu Jin-Hua
    Yin Xue-Feng
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2012, 33 (09): : 1957 - 1963