Chemiluminescence microflow injection analysis system on a chip for the determination of nitrite in food

被引:88
|
作者
He, Deyong [1 ]
Zhang, Zhujun [1 ]
Huang, Ying [1 ]
Hu, Yufei [1 ]
机构
[1] SW Normal Univ, Inst Analyt Sci, Key Lab Analyt Chem Chongqing, Chongqing 400715, Peoples R China
关键词
microflow injection analysis; chemiluminescence; nitrite; chip;
D O I
10.1016/j.foodchem.2006.02.024
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A new microflow injection analysis (mu FIA) system on a chip for the determination of nitrite is described. The chip is produced by using two transparent poly(methylmethacrylate) (PMMA) slices measured 50 x 40 x 5 mm, and the microchannels etched by CO2 laser are 200 mu m wide and 100 mu m deep with the volume of reaction area about 1.8 mu L. Nitrite is sensed by the chemiluminescence (CL) reaction of luminol with ferricyanide that is the product of the reaction of ferrocyanide with nitrite in acidic medium. The syringe pump with an accurate timer controls all reagents, including the sample. The linear range of the nitrite concentration is 8-100 mu g L-1 and the detection limit is 4 mu g L-1 (S/N = 3). The proposed method has good reproducibility with the relative standard deviation 4.1% for 50 mu g L-1 of nitrite (n = 9) and is very sensitive and simple. It has been successfully applied to. the determination of nitrite in food. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:667 / 672
页数:6
相关论文
共 50 条
  • [21] Determination of Nitrite and Nitrate in Freshwaters using Flow Injection Luminol Chemiluminescence Detection
    Attiq-ur-Rehman
    Yaqoob, Mohammad
    Waseem, Amir
    Nabi, Abdul
    ACTA CHIMICA SLOVENICA, 2011, 58 (03) : 569 - 575
  • [22] Research on Determination of Acrylamide in Fried Food by Flow Injection Chemiluminescence
    Li, Yun
    Zhang, Xiuli
    PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON EDUCATION, SPORTS, ARTS AND MANAGEMENT ENGINEERING (ICESAME 2017), 2017, 123 : 724 - 727
  • [23] Determination of paracetamol by flow injection chemiluminescence analysis
    Chen, H
    Zhang, ZJ
    Fu, ZF
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (11) : 1344 - 1347
  • [24] A microflow chemiluminescence system for determination of chloramphenicol in honey with preconcentration using a molecularly imprinted polymer
    Thongchai, Wisanu
    Liawruangath, Boonsom
    Liawruangrath, Saisunee
    Greenway, Gillian M.
    TALANTA, 2010, 82 (02) : 560 - 566
  • [25] Determination of nitrate and nitrite in freshwaters using flow-injection with luminol chemiluminescence detection
    Yaqoob, Mohammad
    Biot, Beatriz Folgado
    Nabi, Abdul
    Worsfold, Paul J.
    LUMINESCENCE, 2012, 27 (05) : 419 - 425
  • [26] FLOW-INJECTION CHEMILUMINESCENCE DETERMINATION OF ULTRA-LOW CONCENTRATIONS OF NITRITE IN WATER
    MIKUSKA, P
    VECERA, Z
    ZDRAHAL, Z
    ANALYTICA CHIMICA ACTA, 1995, 316 (02) : 261 - 268
  • [27] Microflow-injection chemiluminescence of luminol and hypochlorite enhanced by phloxine B
    Song, Xiaoli
    Shen, Hong
    Yin, Xuefeng
    Wang, Xiuzhong
    Liu, Jinhua
    LUMINESCENCE, 2013, 28 (01) : 16 - 22
  • [28] Autoadaptative sequential injection system for nitrite determination in wastewaters
    Baeza, M
    Bartrolí, J
    Alonso, J
    TALANTA, 2005, 68 (02) : 245 - 252
  • [29] Flow injection-chemiluminescence determination of paraben preservative in food safety
    Myint, A
    Zhang, QLO
    Liu, LJ
    Cui, H
    ANALYTICA CHIMICA ACTA, 2004, 517 (1-2) : 119 - 124
  • [30] FLOW INJECTION ANALYSIS CHEMILUMINESCENCE DETERMINATION OF HYDROXYLAMINE HYDROCHLORIDE
    Baezzat, Mohammad Reza
    Izadpanah, Maryam
    BIOLUMINESCENCE AND CHEMILUMINESCENCE, 2009, : 173 - 176