Effect of Noise-Optimized Monoenergetic Postprocessing on Diagnostic Accuracy for Detecting Incidental Pulmonary Embolism in Portal-Venous Phase Dual-Energy Computed Tomography

被引:44
|
作者
Weiss, Jakob [1 ]
Notohamiprodjo, Mike [1 ]
Bongers, Malte [1 ]
Schabel, Christoph [1 ]
Mangold, Stefanie [1 ]
Nikolaou, Konstantin [1 ]
Bamberg, Fabian [1 ]
Othman, Ahmed E. [1 ]
机构
[1] Eberhard Karls Univ Tubingen, Dept Diagnost & Intervent Radiol, Tubingen, Germany
关键词
computed tomography; dual-energy CT; dual-source CT; noise-optimized monoenergetic imaging; pulmonary CT angiography; pulmonary embolism; CT ANGIOGRAPHY; RISK-FACTORS; CANCER-PATIENTS; IMAGE-QUALITY; CONTRAST; RECONSTRUCTION; SETTINGS; STRATIFICATION; THROMBOSIS; DATASETS;
D O I
10.1097/RLI.0000000000000319
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to evaluate the diagnostic accuracy of virtual monoenergetic images (MEI+) at low kiloelectronvolt levels for the detection of incidental pulmonary embolism (PE) in oncological follow-up portal-venous phase dual-energy (DE-CTpv) staging. Materials and Methods: Twenty-six patients with incidental PE in DE-CTpv staging, which was confirmed by computed tomography pulmonary angiography (CTPA), were included in this study. In addition, 26 matched control patientswho were negative for PE in both DE-CTpv and CTPA were included. All examinations were performed on a third-generation DE-CT system in single-energy (CTPA) and dual-energymode (DE-CTpv). Subsequently, 2 series of MEI+ data sets were reconstructed at 40 and 55 keV from the DE-CTpv data and compared with CTPA and the linearly blended CTpv images. Diagnostic accuracy and diagnostic confidence were calculated and compared for MEI+ reconstructions and for CTpv images regarding the detection of PE with CTPA as standard of reference. Results: In 3 patients, PE was only detectable in CTPA and in the 40-kV and 55-kVMEI+ reconstructions but not in CTpv images. Diagnostic accuracy increased significantly for both MEI+ series (40 keV; area under the curve [AUC], 0.928; 95% confidence interval [CI], 0.879-0.978; 55 keV; AUC, 0.960; 95% CI, 0.922-0.998) as compared with CTpv (AUC, 0.814; 95% CI, 0.741-0.887; P = 0.004). Diagnostic confidence was rated highest in CTPA (median, 5; range, 3-5) followed by 55-keV MEI+ and 40-keV MEI+ (median, 5; range, 2-5 and median, 5; range, 2-5, respectively) and was lowest for CTpv (median, 4; range, 1-5), with significant differences to CTPA and MEI+ reconstructions (P = 0.001). Conclusions: Monoenergetic image reconstructions fromDE-CT data sets at low kiloelectronvolt levels improve diagnostic accuracy for the detection of incidental PE in oncological follow-up DE-CTpv staging, with the highest subjective diagnostic confidence in MEI+ at 55 keV.
引用
收藏
页码:142 / 147
页数:6
相关论文
共 33 条
  • [31] Diagnostic accuracy of color-coded virtual noncalcium reconstructions derived from portal venous phase dual-energy CT in the assessment of lumbar disk herniation
    Vitali Koch
    Moritz H. Albrecht
    Leon D. Gruenewald
    Ibrahim Yel
    Katrin Eichler
    Tatjana Gruber-Rouh
    Renate M. Hammerstingl
    Iris Burck
    Julian L. Wichmann
    Leona S. Alizadeh
    Thomas J. Vogl
    Lukas Lenga
    Christoph Mader
    Simon S. Martin
    Silvio Mazziotti
    Tommaso D’Angelo
    Christian Booz
    European Radiology, 2022, 32 : 2168 - 2177
  • [32] Diagnostic accuracy of color-coded virtual noncalcium reconstructions derived from portal venous phase dual-energy CT in the assessment of lumbar disk herniation
    Koch, Vitali
    Albrecht, Moritz H.
    Gruenewald, Leon D.
    Yel, Ibrahim
    Eichler, Katrin
    Gruber-Rouh, Tatjana
    Hammerstingl, Renate M.
    Burck, Iris
    Wichmann, Julian L.
    Alizadeh, Leona S.
    Vogl, Thomas J.
    Lenga, Lukas
    Mader, Christoph
    Martin, Simon S.
    Mazziotti, Silvio
    D'Angelo, Tommaso
    Booz, Christian
    EUROPEAN RADIOLOGY, 2022, 32 (04) : 2168 - 2177
  • [33] Diagnostic accuracy of contrast-enhanced dual-energy computed tomography for detecting metastatic lymph nodes in patients with malignant tumors: a systematic review and meta-analysis
    Kong, Derui
    Chen, Xinyu
    Gao, Peihong
    Zhao, Kexin
    Zheng, Chong
    Zhou, Hongwei
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (05) : 3050 - 3065