Diagnostic accuracy of contrast-enhanced dual-energy computed tomography for detecting metastatic lymph nodes in patients with malignant tumors: a systematic review and meta-analysis

被引:3
|
作者
Kong, Derui [1 ]
Chen, Xinyu [2 ]
Gao, Peihong [1 ]
Zhao, Kexin [1 ]
Zheng, Chong [1 ]
Zhou, Hongwei [1 ,3 ]
机构
[1] First Hosp Jilin Univ, Dept Radiol, Changchun, Peoples R China
[2] First Hosp Jilin Univ, Dept Anesthesiol, Changchun, Peoples R China
[3] First Hosp Jilin Univ, Dept Radiol, 71 Xinmin St, Changchun 130021, Peoples R China
关键词
Radiography; dual-energy computed tomography (DECT); metastatic lymph nodes; cancer; IODINE QUANTIFICATION; THYROID-CANCER; SPECTRAL CT; PARAMETERS; CARCINOMA;
D O I
10.21037/qims-22-527
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: This meta-analysis evaluated the diagnostic accuracy of contrast-enhanced dual-energy computed tomography (DECT) for detecting metastatic lymph nodes in patients with cancer.Methods: PubMed, Embase and Cochrane Library databases were searched for literature published from database inception until September 2022. Only studies that investigated the diagnostic accuracy of DECT for metastatic lymph nodes in patients with malignant tumors and surgically removed metastatic lymph nodes for pathological confirmation were included. The quality of the included studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies tool. The threshold effect was determined by calculating Spearman correlation coefficients and summary receiver operating characteristic (SROC) curve patterns. Deeks test was used to assess publication bias.Results: All of the included studies were observational studies. A total of 16 articles involving 984 patients were included (2,577 lymph nodes) in this review. A total of 15 variables were included in the meta-analysis, including 6 individual parameters and 9 combined parameters. Normalized iodine concentration (NIC) in the arterial phase combined with the slope in the arterial phase showed better identification of metastatic lymph nodes. The spearman correlation coefficient was -0.371 (P=0.468), and the SROC curve did not show a "shoulder-arm" shape, suggesting that there was no threshold effect and that heterogeneity was present. The combined sensitivity was 94% [95% confidence interval (CI): 86-98%], the specificity was 74% (95% CI: 52-88%), and the area under the curve was 0.94. The Deeks test suggested no significant publication bias in the included studies (P=0.06).Conclusions: NIC in arterial phase combined with the slope in the arterial phase has some diagnostic value in differentiating between metastatic and benign lymph nodes, but this should be further evaluated in additional studies with rigorous design and high homogeneity.
引用
收藏
页码:3050 / 3065
页数:23
相关论文
共 50 条
  • [1] Diagnostic performance of dual-energy computed tomography (DECT) quantitative parameters for detecting metastatic cervical lymph nodes in patients with papillary thyroid cancer: A systematic review and meta-analysis
    Zhang, Luyao
    Li, Yize
    Chen, Ziqi
    Dai, Xinpeng
    Gao, Huimin
    Chen, Yingmin
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 183
  • [2] Diagnostic accuracy of dual-energy computed tomography in patients with gout: A meta-analysis
    Lee, Young Ho
    Song, Gwan Gyu
    SEMINARS IN ARTHRITIS AND RHEUMATISM, 2017, 47 (01) : 95 - 101
  • [3] Diagnostic performance of dual-energy computed tomography in detecting anterior cruciate ligament injuries: a systematic review and meta-analysis
    Valizadeh, Parya
    Jannatdoust, Payam
    Pahlevan-Fallahy, Mohammad-Taha
    Bagherieh, Sara
    Adli, Paniz
    Amoukhteh, Melika
    Hassankhani, Amir
    Matcuk Jr, George R.
    Gholamrezanezhad, Ali
    SKELETAL RADIOLOGY, 2024, : 1247 - 1262
  • [4] The diagnostic performance of contrast-enhanced ultrasound versus contrast-enhanced computed tomography for pancreatic carcinoma: a systematic review and meta-analysis
    Yan, Xiaoyi
    Lv, Ke
    Xiao, Mengsu
    Tan, Li
    Gui, Yang
    Zhang, Jing
    Chen, Xueqi
    Jia, Wanying
    Li, Jinglin
    TRANSLATIONAL CANCER RESEARCH, 2022, : 3645 - 3656
  • [5] Dual-Energy Computed Tomography in Spine Fractures: A Systematic Review and Meta-Analysis
    Baecker, Henrik C.
    Wu, Chia H.
    Perka, Carsten
    Panics, Gergely
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2021, 15 (03): : 525 - 535
  • [6] Diagnostic accuracy of dual-energy CT in gout: a systematic review and meta-analysis
    Zhange Yu
    Tianli Mao
    Yaping Xu
    Tengqi Li
    Yanhua Wang
    Fuqiang Gao
    Wei Sun
    Skeletal Radiology, 2018, 47 : 1587 - 1593
  • [7] Diagnostic accuracy of dual-energy CT in gout: a systematic review and meta-analysis
    Yu, Zhange
    Mao, Tianli
    Xu, Yaping
    Li, Tengqi
    Wang, Yanhua
    Gao, Fuqiang
    Sun, Wei
    SKELETAL RADIOLOGY, 2018, 47 (12) : 1587 - 1593
  • [8] Assessing diagnostic value of contrast-enhanced ultrasound and contrast-enhanced computed tomography in detecting small hepatocellular carcinoma A meta-analysis
    Huang, Jiasheng
    Chen, Wei
    Yao, Shanwen
    MEDICINE, 2017, 96 (30)
  • [9] The diagnostic value of contrast-enhanced computed tomography imaging for detection of colorectal tumors: A meta-analysis
    Yu, Qing
    Liu, Jie
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2016, 12 (08) : 241 - 243
  • [10] Diagnostic accuracy of contrast-enhanced ultrasound to differentiate benign and malignant breast lesions: A systematic review and meta-analysis
    Wang, Jing
    Zhao, Rui
    Cheng, Jia
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 149