Diagnostic accuracy of contrast-enhanced dual-energy computed tomography for detecting metastatic lymph nodes in patients with malignant tumors: a systematic review and meta-analysis

被引:3
|
作者
Kong, Derui [1 ]
Chen, Xinyu [2 ]
Gao, Peihong [1 ]
Zhao, Kexin [1 ]
Zheng, Chong [1 ]
Zhou, Hongwei [1 ,3 ]
机构
[1] First Hosp Jilin Univ, Dept Radiol, Changchun, Peoples R China
[2] First Hosp Jilin Univ, Dept Anesthesiol, Changchun, Peoples R China
[3] First Hosp Jilin Univ, Dept Radiol, 71 Xinmin St, Changchun 130021, Peoples R China
关键词
Radiography; dual-energy computed tomography (DECT); metastatic lymph nodes; cancer; IODINE QUANTIFICATION; THYROID-CANCER; SPECTRAL CT; PARAMETERS; CARCINOMA;
D O I
10.21037/qims-22-527
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: This meta-analysis evaluated the diagnostic accuracy of contrast-enhanced dual-energy computed tomography (DECT) for detecting metastatic lymph nodes in patients with cancer.Methods: PubMed, Embase and Cochrane Library databases were searched for literature published from database inception until September 2022. Only studies that investigated the diagnostic accuracy of DECT for metastatic lymph nodes in patients with malignant tumors and surgically removed metastatic lymph nodes for pathological confirmation were included. The quality of the included studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies tool. The threshold effect was determined by calculating Spearman correlation coefficients and summary receiver operating characteristic (SROC) curve patterns. Deeks test was used to assess publication bias.Results: All of the included studies were observational studies. A total of 16 articles involving 984 patients were included (2,577 lymph nodes) in this review. A total of 15 variables were included in the meta-analysis, including 6 individual parameters and 9 combined parameters. Normalized iodine concentration (NIC) in the arterial phase combined with the slope in the arterial phase showed better identification of metastatic lymph nodes. The spearman correlation coefficient was -0.371 (P=0.468), and the SROC curve did not show a "shoulder-arm" shape, suggesting that there was no threshold effect and that heterogeneity was present. The combined sensitivity was 94% [95% confidence interval (CI): 86-98%], the specificity was 74% (95% CI: 52-88%), and the area under the curve was 0.94. The Deeks test suggested no significant publication bias in the included studies (P=0.06).Conclusions: NIC in arterial phase combined with the slope in the arterial phase has some diagnostic value in differentiating between metastatic and benign lymph nodes, but this should be further evaluated in additional studies with rigorous design and high homogeneity.
引用
收藏
页码:3050 / 3065
页数:23
相关论文
共 50 条
  • [41] Diagnostic accuracy of dual-energy computed tomography (DECT) to differentiate uric acid from non-uric acid calculi: systematic review and meta-analysis
    McGrath, Trevor A.
    Frank, Robert A.
    Schieda, Nicola
    Blew, Brian
    Salameh, Jean-Paul
    Bossuyt, Patrick M. M.
    McInnes, Matthew D. F.
    EUROPEAN RADIOLOGY, 2020, 30 (05) : 2791 - 2801
  • [42] Coronary calcium quantification using contrast-enhanced dual-energy computed tomography scans
    Yamak, Didem
    Pavlicek, William
    Boltz, Thomas
    Panse, Prasad M.
    Akay, Metin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (03): : 203 - 214
  • [43] The Use of Contrast-Enhanced Sonography for Therapy Monitoring of Metastatic Lymph Nodes: A Systematic Review
    Rink, Maximilian
    Jung, Ernst-Michael
    Kuenzel, Julian
    CURRENT ONCOLOGY, 2023, 30 (07) : 6734 - 6743
  • [44] Diagnostic performance of contrast-enhanced spectral mammography: Systematic review and meta-analysis
    Tagliafico, Alberto Stefano
    Bignotti, Bianca
    Rossi, Federica
    Signori, Alessio
    Sormani, Maria Pia
    Valdora, Francesca
    Calabrese, Massimo
    Houssami, Nehmat
    BREAST, 2016, 28 : 13 - 19
  • [45] Diagnostic accuracy of contrast-enhanced ultrasound in assessing the therapeutic response to radio frequency ablation for liver tumors: systematic review and meta-analysis
    Xuan, Min
    Zhou, Fengsheng
    Ding, Yan
    Zhu, Qiaoying
    Dong, Ji
    Zhou, Hao
    Cheng, Jun
    Jiang, Xiao
    Wu, Pengxi
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2018, 32 (04): : 2067 - 2075
  • [46] Diagnostic accuracy of contrast-enhanced ultrasound in assessing the therapeutic response to radio frequency ablation for liver tumors: systematic review and meta-analysis
    Min Xuan
    Fengsheng Zhou
    Yan Ding
    Qiaoying Zhu
    Ji Dong
    Hao Zhou
    Jun Cheng
    Xiao Jiang
    Pengxi Wu
    Surgical Endoscopy, 2018, 32 : 2067 - 2075
  • [47] Contrast-enhanced endoscopic ultrasound for the differential diagnosis between benign and malignant lymph nodes: a meta-analysis
    Lisotti, Andrea
    Ricci, Claudio
    Serrani, Marta
    Calvanese, Claudio
    Sferrazza, Sandro
    Brighi, Nicole
    Casadei, Riccardo
    Fusaroli, Pietro
    ENDOSCOPY INTERNATIONAL OPEN, 2019, 7 (04) : E504 - E513
  • [48] Contrast-enhanced ultrasound for the differential diagnosis between benign and metastatic superficial lymph nodes: a meta-analysis
    Mei, Mei
    Ye, Ligang
    Quan, Juan
    Huang, Pintong
    CANCER MANAGEMENT AND RESEARCH, 2018, 10 : 4987 - 4997
  • [49] Diagnostic Accuracy of Sonoelastography in Detecting Malignant Thyroid Nodules: A Systematic Review and Meta-Analysis
    Ghajarzadeh, Mahsa
    Sodagari, Faezeh
    Shakiba, Madjid
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (04) : W379 - W389
  • [50] Diagnostic accuracy of contrast-enhanced ultrasound in the detection of small renal masses A protocol of systematic review and meta-analysis
    Wu, Jiang-feng
    Wu, Chao
    Wang, Yun-lai
    Wang, Zheng-ping
    MEDICINE, 2020, 99 (29) : E21262