Effect of Noise-Optimized Monoenergetic Postprocessing on Diagnostic Accuracy for Detecting Incidental Pulmonary Embolism in Portal-Venous Phase Dual-Energy Computed Tomography

被引:44
|
作者
Weiss, Jakob [1 ]
Notohamiprodjo, Mike [1 ]
Bongers, Malte [1 ]
Schabel, Christoph [1 ]
Mangold, Stefanie [1 ]
Nikolaou, Konstantin [1 ]
Bamberg, Fabian [1 ]
Othman, Ahmed E. [1 ]
机构
[1] Eberhard Karls Univ Tubingen, Dept Diagnost & Intervent Radiol, Tubingen, Germany
关键词
computed tomography; dual-energy CT; dual-source CT; noise-optimized monoenergetic imaging; pulmonary CT angiography; pulmonary embolism; CT ANGIOGRAPHY; RISK-FACTORS; CANCER-PATIENTS; IMAGE-QUALITY; CONTRAST; RECONSTRUCTION; SETTINGS; STRATIFICATION; THROMBOSIS; DATASETS;
D O I
10.1097/RLI.0000000000000319
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to evaluate the diagnostic accuracy of virtual monoenergetic images (MEI+) at low kiloelectronvolt levels for the detection of incidental pulmonary embolism (PE) in oncological follow-up portal-venous phase dual-energy (DE-CTpv) staging. Materials and Methods: Twenty-six patients with incidental PE in DE-CTpv staging, which was confirmed by computed tomography pulmonary angiography (CTPA), were included in this study. In addition, 26 matched control patientswho were negative for PE in both DE-CTpv and CTPA were included. All examinations were performed on a third-generation DE-CT system in single-energy (CTPA) and dual-energymode (DE-CTpv). Subsequently, 2 series of MEI+ data sets were reconstructed at 40 and 55 keV from the DE-CTpv data and compared with CTPA and the linearly blended CTpv images. Diagnostic accuracy and diagnostic confidence were calculated and compared for MEI+ reconstructions and for CTpv images regarding the detection of PE with CTPA as standard of reference. Results: In 3 patients, PE was only detectable in CTPA and in the 40-kV and 55-kVMEI+ reconstructions but not in CTpv images. Diagnostic accuracy increased significantly for both MEI+ series (40 keV; area under the curve [AUC], 0.928; 95% confidence interval [CI], 0.879-0.978; 55 keV; AUC, 0.960; 95% CI, 0.922-0.998) as compared with CTpv (AUC, 0.814; 95% CI, 0.741-0.887; P = 0.004). Diagnostic confidence was rated highest in CTPA (median, 5; range, 3-5) followed by 55-keV MEI+ and 40-keV MEI+ (median, 5; range, 2-5 and median, 5; range, 2-5, respectively) and was lowest for CTpv (median, 4; range, 1-5), with significant differences to CTPA and MEI+ reconstructions (P = 0.001). Conclusions: Monoenergetic image reconstructions fromDE-CT data sets at low kiloelectronvolt levels improve diagnostic accuracy for the detection of incidental PE in oncological follow-up DE-CTpv staging, with the highest subjective diagnostic confidence in MEI+ at 55 keV.
引用
收藏
页码:142 / 147
页数:6
相关论文
共 33 条
  • [11] A noise-optimized virtual monoenergetic reconstruction algorithm improves the diagnostic accuracy of late hepatic arterial phase dual-energy CT for the detection of hypervascular liver lesions
    De Cecco, Carlo N.
    Caruso, Damiano
    Schoepf, U. Joseph
    De Santis, Domenico
    Muscogiuri, Giuseppe
    Albrecht, Moritz H.
    Meinel, Felix G.
    Wichmann, Julian L.
    Burchett, Philip F.
    Varga-Szemes, Akos
    Sheafor, Douglas H.
    Hardie, Andrew D.
    EUROPEAN RADIOLOGY, 2018, 28 (08) : 3393 - 3404
  • [12] A noise-optimized virtual monoenergetic reconstruction algorithm improves the diagnostic accuracy of late hepatic arterial phase dual-energy CT for the detection of hypervascular liver lesions
    Carlo N. De Cecco
    Damiano Caruso
    U. Joseph Schoepf
    Domenico De Santis
    Giuseppe Muscogiuri
    Moritz H. Albrecht
    Felix G. Meinel
    Julian L. Wichmann
    Philip F. Burchett
    Akos Varga-Szemes
    Douglas H. Sheafor
    Andrew D. Hardie
    European Radiology, 2018, 28 : 3393 - 3404
  • [13] Improvement of image quality of laryngeal squamous cell carcinoma using noise-optimized virtual monoenergetic image and nonlinear blending image algorithms in dual-energy computed tomography
    He, Changjiu
    Liu, Jieke
    Hu, Shibei
    Qing, Haomiao
    Luo, Hongbing
    Chen, Xiaoli
    Liu, Ying
    Zhou, Peng
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2021, 43 (10): : 3125 - 3131
  • [14] Identification of pulmonary embolism: diagnostic accuracy of venous-phase dual-energy CT in comparison to pulmonary arteries CT angiography
    Giovanni Foti
    Ronaldo Silva
    Niccolò Faccioli
    Alessandro Fighera
    Rossella Menghini
    Arianna Campagnola
    Giovanni Carbognin
    European Radiology, 2021, 31 : 1923 - 1931
  • [15] Identification of pulmonary embolism: diagnostic accuracy of venous-phase dual-energy CT in comparison to pulmonary arteries CT angiography
    Foti, Giovanni
    Silva, Ronaldo
    Faccioli, Niccolo
    Fighera, Alessandro
    Menghini, Rossella
    Campagnola, Arianna
    Carbognin, Giovanni
    EUROPEAN RADIOLOGY, 2021, 31 (04) : 1923 - 1931
  • [16] Virtual Monoenergetic Imaging and Iodine Perfusion Maps Improve Diagnostic Accuracy of Dual-Energy Computed Tomography Pulmonary Angiography With Suboptimal Contrast Attenuation
    Leithner, Doris
    Wichmann, Julian L.
    Vogl, Thomas J.
    Trommer, Jesko
    Martin, Simon S.
    Scholtz, Jan-Erik
    Bodelle, Boris
    De Cecco, Carlo N.
    Duguay, Taylor
    Nance, John W., Jr.
    Schoepf, U. Joseph
    Albrecht, Moritz H.
    INVESTIGATIVE RADIOLOGY, 2017, 52 (11) : 659 - 665
  • [17] Diagnostic Impact of Quantitative Dual-Energy Computed Tomography Perfusion Imaging for the Assessment of Subsegmental Pulmonary Embolism
    Celtikci, Pinar
    Hekimoglu, Koray
    Kahraman, Gokhan
    Bozbas, Serife
    Gultekin, Bahadir
    Akay, Hakki Tankut
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (01) : 151 - 156
  • [18] Initial Investigation of Clinical Value of Noise-Optimized Virtual Monoenergetic Images Derived From Dual-Energy Computed Tomography Angiography in Preoperative Perforator Planning of Anterolateral Thigh Flap Transplantation
    Li, Xiaoqin
    Zhang, Jing
    Shen, Hesong
    Wang, Xiaoxia
    Liu, Daihong
    Yu, Hong
    Lan, Xiaosong
    Shi, Jinfang
    Zeng, Xiangfei
    Liu, Meiling
    Lin, Meng
    Tan, Yong
    Zhang, Bin
    Zhang, Jiuquan
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (04) : 560 - 567
  • [19] Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography
    D'Angelo, Tommaso
    Bucher, Andreas M.
    Lenga, Lukas
    Arendt, Christophe T.
    Peterke, Julia L.
    Caruso, Damiano
    Mazziotti, Silvio
    Blandino, Alfredo
    Ascenti, Giorgio
    Othman, Ahmed E.
    Martin, Simon S.
    Leithner, Doris
    Vogl, Thomas J.
    Wichmann, Julian L.
    EUROPEAN RADIOLOGY, 2018, 28 (04) : 1393 - 1401
  • [20] Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography
    Tommaso D’Angelo
    Andreas M. Bucher
    Lukas Lenga
    Christophe T. Arendt
    Julia L. Peterke
    Damiano Caruso
    Silvio Mazziotti
    Alfredo Blandino
    Giorgio Ascenti
    Ahmed E. Othman
    Simon S. Martin
    Doris Leithner
    Thomas J. Vogl
    Julian L. Wichmann
    European Radiology, 2018, 28 : 1393 - 1401