Effect of Noise-Optimized Monoenergetic Postprocessing on Diagnostic Accuracy for Detecting Incidental Pulmonary Embolism in Portal-Venous Phase Dual-Energy Computed Tomography

被引:44
|
作者
Weiss, Jakob [1 ]
Notohamiprodjo, Mike [1 ]
Bongers, Malte [1 ]
Schabel, Christoph [1 ]
Mangold, Stefanie [1 ]
Nikolaou, Konstantin [1 ]
Bamberg, Fabian [1 ]
Othman, Ahmed E. [1 ]
机构
[1] Eberhard Karls Univ Tubingen, Dept Diagnost & Intervent Radiol, Tubingen, Germany
关键词
computed tomography; dual-energy CT; dual-source CT; noise-optimized monoenergetic imaging; pulmonary CT angiography; pulmonary embolism; CT ANGIOGRAPHY; RISK-FACTORS; CANCER-PATIENTS; IMAGE-QUALITY; CONTRAST; RECONSTRUCTION; SETTINGS; STRATIFICATION; THROMBOSIS; DATASETS;
D O I
10.1097/RLI.0000000000000319
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to evaluate the diagnostic accuracy of virtual monoenergetic images (MEI+) at low kiloelectronvolt levels for the detection of incidental pulmonary embolism (PE) in oncological follow-up portal-venous phase dual-energy (DE-CTpv) staging. Materials and Methods: Twenty-six patients with incidental PE in DE-CTpv staging, which was confirmed by computed tomography pulmonary angiography (CTPA), were included in this study. In addition, 26 matched control patientswho were negative for PE in both DE-CTpv and CTPA were included. All examinations were performed on a third-generation DE-CT system in single-energy (CTPA) and dual-energymode (DE-CTpv). Subsequently, 2 series of MEI+ data sets were reconstructed at 40 and 55 keV from the DE-CTpv data and compared with CTPA and the linearly blended CTpv images. Diagnostic accuracy and diagnostic confidence were calculated and compared for MEI+ reconstructions and for CTpv images regarding the detection of PE with CTPA as standard of reference. Results: In 3 patients, PE was only detectable in CTPA and in the 40-kV and 55-kVMEI+ reconstructions but not in CTpv images. Diagnostic accuracy increased significantly for both MEI+ series (40 keV; area under the curve [AUC], 0.928; 95% confidence interval [CI], 0.879-0.978; 55 keV; AUC, 0.960; 95% CI, 0.922-0.998) as compared with CTpv (AUC, 0.814; 95% CI, 0.741-0.887; P = 0.004). Diagnostic confidence was rated highest in CTPA (median, 5; range, 3-5) followed by 55-keV MEI+ and 40-keV MEI+ (median, 5; range, 2-5 and median, 5; range, 2-5, respectively) and was lowest for CTpv (median, 4; range, 1-5), with significant differences to CTPA and MEI+ reconstructions (P = 0.001). Conclusions: Monoenergetic image reconstructions fromDE-CT data sets at low kiloelectronvolt levels improve diagnostic accuracy for the detection of incidental PE in oncological follow-up DE-CTpv staging, with the highest subjective diagnostic confidence in MEI+ at 55 keV.
引用
收藏
页码:142 / 147
页数:6
相关论文
共 33 条
  • [21] Can dual-energy computed tomography improve visualization of hypoenhancing liver lesions in portal venous phase? Assessment of advanced image-based virtual monoenergetic images
    Caruso, Damiano
    De Cecco, Carlo N.
    Schoepf, U. Joseph
    Schaefer, Amanda R.
    Leland, Parker W.
    Johnson, Dustin
    Laghi, Andrea
    Hardie, Andrew D.
    CLINICAL IMAGING, 2017, 41 : 118 - 124
  • [22] Noise-optimized virtual monoenergetic images and iodine maps for the detection of venous thrombosis in second-generation dual-energy CT (DECT): an ex vivo phantom study
    Malte N. Bongers
    Christoph Schabel
    Bernhard Krauss
    Ilias Tsiflikas
    Dominik Ketelsen
    Stefanie Mangold
    Claus D. Claussen
    Konstantin Nikolaou
    Christoph Thomas
    European Radiology, 2015, 25 : 1655 - 1664
  • [23] Noise-optimized virtual monoenergetic images and iodine maps for the detection of venous thrombosis in second-generation dual-energy CT (DECT): an ex vivo phantom study
    Bongers, Malte N.
    Schabel, Christoph
    Krauss, Bernhard
    Tsiflikas, Ilias
    Ketelsen, Dominik
    Mangold, Stefanie
    Claussen, Claus D.
    Nikolaou, Konstantin
    Thomas, Christoph
    EUROPEAN RADIOLOGY, 2015, 25 (06) : 1655 - 1664
  • [24] Diagnostic performance of single-phase dual-energy CT to differentiate vascular and nonvascular incidental renal lesions on portal venous phase: comparison with CT
    Mastrodicasa, Domenico
    Willemink, Martin J.
    Madhuripan, Nikhil
    Chima, Ranjit Singh
    Ho, Amanzo A.
    Ding, Yuqin
    Marin, Daniele
    Patel, Bhavik N.
    EUROPEAN RADIOLOGY, 2021, 31 (12) : 9600 - 9611
  • [25] Diagnostic performance of single-phase dual-energy CT to differentiate vascular and nonvascular incidental renal lesions on portal venous phase: comparison with CT
    Domenico Mastrodicasa
    Martin J. Willemink
    Nikhil Madhuripan
    Ranjit Singh Chima
    Amanzo A. Ho
    Yuqin Ding
    Daniele Marin
    Bhavik N Patel
    European Radiology, 2021, 31 : 9600 - 9611
  • [26] Evaluation of Diagnostic Accuracy and Radiation Exposure of Dual-Energy Computed Tomography (DECT) in the Course of Chronic Thromboembolic Pulmonary Hypertension (CTEPH)
    Schuessler, Armin
    Richter, Manuel
    Tello, Khodr
    Steiner, Dagmar
    Seeger, Werner
    Krombach, Gabriele Anja
    Roller, Fritz Christian
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (11): : 1318 - 1326
  • [27] Evaluation of diagnostic accuracy of dual-energy computed tomography in patients with chronic thromboembolic pulmonary hypertension compared to V/Q-SPECT and pulmonary angiogram
    Schuessler, Armin
    Lug, Quirin
    Kremer, Nils
    Harth, Sebastian
    Kriechbaum, Steffen D.
    Richter, Manuel J.
    Guth, Stefan
    Wiedenroth, Christoph B.
    Tello, Khodr
    Steiner, Dagmar
    Seeger, Werner
    Krombach, Gabriele Anja
    Roller, Fritz Christian
    FRONTIERS IN MEDICINE, 2023, 10
  • [28] Iodine Distribution Map in Dual-Energy Computed Tomography Pulmonary Artery Imaging with Rapid kVp Switching for the Diagnostic Analysis and Quantitative Evaluation of Acute Pulmonary Embolism
    Cai, Xiang-Ran
    Feng, You-Zhen
    Qiu, Lin
    Xian, Zhao-Hui
    Yang, Wen-Cai
    Mo, Xu-Kai
    Wang, Xiao-Bai
    ACADEMIC RADIOLOGY, 2015, 22 (06) : 743 - 751
  • [29] Dual-Energy Computed Tomography-Based Display of Bone Marrow Edema in Incidental Vertebral Compression Fractures Diagnostic Accuracy and Characterization in Oncological Patients Undergoing Routine Staging Computed Tomography
    Frellesen, Claudia
    Azadegan, Mehrnoush
    Martin, Simon S.
    Otani, Katharina
    D'Angelo, Tommaso
    Booz, Christian
    Eichler, Katrin
    Panahi, Bita
    Kaup, Moritz
    Bauer, Ralf W.
    Vogl, Thomas J.
    Wichmann, Julian L.
    INVESTIGATIVE RADIOLOGY, 2018, 53 (07) : 409 - 416
  • [30] Dual-Energy Computed Tomography in Patients With Small Hepatocellular Carcinoma: Utility of Noise-Reduced Monoenergetic Images for the Evaluation of Washout and Image Quality in the Equilibrium Phase
    Matsuda, Megumi
    Tsuda, Takaharu
    Kido, Teruhito
    Tanaka, Hiroaki
    Nishiyama, Hikaru
    Itoh, Toshihide
    Nakao, Kenichi
    Hirooka, Masashi
    Mochizuki, Teruhito
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 937 - 943