Discriminant Value of Custom Ocular Response Analyzer Waveform Derivatives in Keratoconus

被引:68
|
作者
Hallahan, Katie M. [1 ]
Roy, Abhijit Sinha [1 ]
Ambrosio, Renato, Jr. [2 ,3 ]
Salomao, Marcella [1 ,2 ]
Dupps, William J., Jr. [1 ,4 ]
机构
[1] Cleveland Clin, Cole Eye Inst, Cleveland, OH 44195 USA
[2] Inst Olhos, Rio De Janeiro, Brazil
[3] Univ Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
[4] Cleveland Clin, Lerner Res Inst, Cleveland, OH 44195 USA
关键词
IN-SITU KERATOMILEUSIS; BIOMECHANICAL PROPERTIES; CORNEAL HYSTERESIS; PORCINE; ECTASIA; RISK;
D O I
10.1016/j.ophtha.2013.09.013
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the performance of corneal hysteresis (CH), corneal resistance factor, and 16 investigator-derived Ocular Response Analyzer (ORA) variables in distinguishing keratoconus (KC) from the nondiseased state. Design: Retrospective case series. Participants: Fifty-four eyes of 27 unaffected patients and 49 eyes of 25 KC patients from the Instituto de Olhos, Rio de Janeiro, Brazil. Methods: Sixteen candidate variables were derived from exported ORA signals to characterize putative indicators of biomechanical behavior. Area under the receiver operating characteristic curve (AUC) and the Z statistic were used to compare diagnostic performance. Main Outcome Measures: Discriminant value of standard and derived ORA variables as measured by AUC. Results: Fifteen of 16 candidate variables performed significantly better than chance (AUC, > 0.5) at discriminating KC. Diagnostic performance was greatest for a custom variable related to the depth of deformation as defined by the minimum applanation signal intensity during corneal deformation (concavity(min); mean AUC +/- standard error, 0.985 +/- 0.002) and a new measure incorporating the pressure-deformation relationship of the entire response cycle (hysteresis loop area, 0.967 +/- 0.002). Z statistics assessing the discriminative value of each of the top 5 variables demonstrated superiority to CH (AUC, 0.862 +/- 0.002). Concavity(min) had the best overall predictive accuracy (cutoff value, 50.37; 94.9% sensitivity, 91.7% specificity, and 93.2% test accuracy), and the top 4 variables demonstrated the most consistent relationships to KC severity. Conclusions: Investigator-derived ORA variables related to the depth of deformation and the pressuredeformation relationship demonstrated very high test accuracy for detecting the presence of KC. Beyond their diagnostic value, the candidate variables described in this report provide mechanistic insight into the nature of the ORA signal and the characteristic changes in corneal dynamics associated with KC. (C) 2014 by the American Academy of Ophthalmology.
引用
收藏
页码:459 / 468
页数:10
相关论文
共 50 条
  • [1] Discriminant Value of Custom Ocular Response Analyzer Waveform Derivatives in Forme Fruste Keratoconus
    Luz, Allan
    Lopes, Bernardo
    Hallahan, Katie M.
    Valbon, Bruno
    Fontes, Bruno
    Schor, Paulo
    Dupps, William J., Jr.
    Ambrosio, Renato, Jr.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 164 : 14 - 21
  • [2] The Usability of the New Waveform Parameters From the Ocular Response Analyzer in the Characterization of Keratoconus
    Michael, R.
    Mikielewicz, M.
    Kotliar, K.
    Barraquer, R. I.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [3] Methodology for Keratoconus Risk Indices Using Ocular Response Analyzer (ORA) Waveform Analysis
    Luce, D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [4] Effect of accelerated corneal crosslinking on ocular response analyzer waveform-derived parameters in progressive keratoconus
    Uzel, Mehmet Murat
    Koc, Mustafa
    Can, Cigdem
    Polat, Sibel
    Yilmazbas, Pelin
    Ileri, Dilek
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2019, 82 (01) : 18 - 24
  • [5] Screening of Forme Fruste Keratoconus with the Ocular Response Analyzer
    Schweitzer, Cedric
    Roberts, Cynthia J.
    Mahmoud, Ashraf M.
    Colin, Joseph
    Maurice-Tison, Sylvie
    Kerautret, Julien
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (05) : 2403 - 2410
  • [6] The Usefulness of Waveform Score from the Ocular Response Analyzer
    Lam, Andrew K. C.
    Chen, Davie
    Tse, Jimmy
    OPTOMETRY AND VISION SCIENCE, 2010, 87 (03) : 195 - 199
  • [7] Keratoconus cone location influences ocular biomechanical parameters measured by the Ocular Response Analyzer
    Yuhas, Phillip T.
    Fortman, Maddison M.
    Mahmoud, Ashraf M.
    Roberts, Cynthia J.
    EYE AND VISION, 2024, 11 (01)
  • [8] Keratoconus cone location influences ocular biomechanical parameters measured by the Ocular Response Analyzer
    Phillip T. Yuhas
    Maddison M. Fortman
    Ashraf M. Mahmoud
    Cynthia J. Roberts
    Eye and Vision, 11
  • [9] Effects of Corneal Cross-Linking on Ocular Response Analyzer Waveform-Derived Variables in Keratoconus and Postrefractive Surgery Ectasia
    Hallahan, Katie M.
    Rocha, Karolinne
    Roy, Abhijit S.
    Randleman, J. Bradley
    Stulting, R. Doyle
    Dupps, William J., Jr.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2014, 40 (06): : 339 - 344
  • [10] Effects of corneal collagen crosslinking on Ocular Response Analyzer Waveform-derived variables in keratoconus and post-LASIK ectasia
    Hallahan, Katie Marie
    Rocha, Karolinne
    Roy, Abhijit Sinha
    Randleman, James Bradley
    Stulting, R. Doyle
    Dupps, William J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)