Discriminant Value of Custom Ocular Response Analyzer Waveform Derivatives in Keratoconus

被引:68
|
作者
Hallahan, Katie M. [1 ]
Roy, Abhijit Sinha [1 ]
Ambrosio, Renato, Jr. [2 ,3 ]
Salomao, Marcella [1 ,2 ]
Dupps, William J., Jr. [1 ,4 ]
机构
[1] Cleveland Clin, Cole Eye Inst, Cleveland, OH 44195 USA
[2] Inst Olhos, Rio De Janeiro, Brazil
[3] Univ Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
[4] Cleveland Clin, Lerner Res Inst, Cleveland, OH 44195 USA
关键词
IN-SITU KERATOMILEUSIS; BIOMECHANICAL PROPERTIES; CORNEAL HYSTERESIS; PORCINE; ECTASIA; RISK;
D O I
10.1016/j.ophtha.2013.09.013
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the performance of corneal hysteresis (CH), corneal resistance factor, and 16 investigator-derived Ocular Response Analyzer (ORA) variables in distinguishing keratoconus (KC) from the nondiseased state. Design: Retrospective case series. Participants: Fifty-four eyes of 27 unaffected patients and 49 eyes of 25 KC patients from the Instituto de Olhos, Rio de Janeiro, Brazil. Methods: Sixteen candidate variables were derived from exported ORA signals to characterize putative indicators of biomechanical behavior. Area under the receiver operating characteristic curve (AUC) and the Z statistic were used to compare diagnostic performance. Main Outcome Measures: Discriminant value of standard and derived ORA variables as measured by AUC. Results: Fifteen of 16 candidate variables performed significantly better than chance (AUC, > 0.5) at discriminating KC. Diagnostic performance was greatest for a custom variable related to the depth of deformation as defined by the minimum applanation signal intensity during corneal deformation (concavity(min); mean AUC +/- standard error, 0.985 +/- 0.002) and a new measure incorporating the pressure-deformation relationship of the entire response cycle (hysteresis loop area, 0.967 +/- 0.002). Z statistics assessing the discriminative value of each of the top 5 variables demonstrated superiority to CH (AUC, 0.862 +/- 0.002). Concavity(min) had the best overall predictive accuracy (cutoff value, 50.37; 94.9% sensitivity, 91.7% specificity, and 93.2% test accuracy), and the top 4 variables demonstrated the most consistent relationships to KC severity. Conclusions: Investigator-derived ORA variables related to the depth of deformation and the pressuredeformation relationship demonstrated very high test accuracy for detecting the presence of KC. Beyond their diagnostic value, the candidate variables described in this report provide mechanistic insight into the nature of the ORA signal and the characteristic changes in corneal dynamics associated with KC. (C) 2014 by the American Academy of Ophthalmology.
引用
收藏
页码:459 / 468
页数:10
相关论文
共 50 条
  • [41] Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
    Luce, DA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01): : 156 - 162
  • [42] Combining Ocular Response Analyzer Metrics for Corneal Biomechanical Diagnosis
    Ruisenor Vazquez, Pablo R.
    Delrivo, Marianella
    Fuentes Bonthoux, Fernando
    Pfoertner, Tomas
    Gaston Galletti, Jeremias
    JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (09) : 596 - +
  • [43] Ocular Response Analyzer: feasibility study and correlation with normal eyes
    Montard, R.
    Kopito, R.
    Touzeau, O.
    Allouch, C.
    Letaief, I.
    Borderie, V.
    Laroche, L.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2007, 30 (10): : 978 - 984
  • [44] Brillouin ocular analyzer detects biomechanical changes in corneal tissues in the early stages of keratoconus and after corneal crosslinking
    Shao, Peng
    Eltony, Amira M.
    Seiler, Theo G.
    Tavakol, Behrouz
    Pineda, Roberto, II
    Seiler, Theo
    Yun, Seok-Hyun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [45] Keratoconus corneas deform more than normal corneas in response to the ocular pulse
    Liu, Jun
    Kwok, Sunny
    Pan, Xueliang
    Hendershot, Andrew
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [46] Ocular Response Analyzer and Goldmann Applanation Tonometry: A Comparative Study of Findings
    Bayoumi, Nader Hussien Lutfy
    Bessa, Amr Saad
    El Massry, Ahmed Abdel Karim
    JOURNAL OF GLAUCOMA, 2010, 19 (09) : 627 - 631
  • [47] Corneal biomechanical properties measured by the ocular response analyzer in acromegalic patients
    Sen, Emine
    Tutuncu, Yasemin
    Balikoglu-Yilmaz, Melike
    Elgin, Ufuk
    Berker, Dilek
    Ozturk, Faruk
    Guler, Serdar
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (08) : 1283 - 1288
  • [48] The usefulness of CorvisST Tonometry and the Ocular Response Analyzer to assess the progression of glaucoma
    Matsuura, Masato
    Hirasawa, Kazunori
    Murata, Hiroshi
    Nakakura, Shunsuke
    Kiuchi, Yoshiaki
    Asaoka, Ryo
    SCIENTIFIC REPORTS, 2017, 7
  • [49] Repeatability of Ocular Response Analyzer Metrics: A Gender-Based Study
    David, Vinoo Philip
    Stead, Richard E.
    Vernon, Stephen A.
    OPTOMETRY AND VISION SCIENCE, 2013, 90 (07) : 691 - 699
  • [50] Corneal hysteresis measured with the Ocular Response Analyzer® in normal and glaucomatous eyes
    Abitbol, Olivia
    Bouden, Jihene
    Doan, Serge
    Hoang-Xuan, Thanh
    Gatinel, Damien
    ACTA OPHTHALMOLOGICA, 2010, 88 (01) : 116 - 119