Screening of Forme Fruste Keratoconus with the Ocular Response Analyzer

被引:99
|
作者
Schweitzer, Cedric [1 ]
Roberts, Cynthia J. [2 ]
Mahmoud, Ashraf M. [2 ]
Colin, Joseph [1 ]
Maurice-Tison, Sylvie [1 ]
Kerautret, Julien [1 ]
机构
[1] Univ Hosp Pellegrin, Dept Ophthalmol, Natl Reference Ctr Keratoconus, Bordeaux, France
[2] Ohio State Univ, Dept Biomed Engn Ophthalmol & Surg, Columbus, OH 43210 USA
关键词
IN-SITU KERATOMILEUSIS; CENTRAL CORNEAL THICKNESS; ACADEMY-OF-OPHTHALMOLOGY; WAVE-FRONT ABERRATIONS; RESIDUAL STROMAL BED; BIOMECHANICAL PROPERTIES; REFRACTIVE SURGERY; FEMTOSECOND LASER; UNILATERAL KERATOCONUS; INTRAOCULAR-PRESSURE;
D O I
10.1167/iovs.09-3689
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To evaluate the performance of the Ocular Response Analyzer (ORA) in the screening of forme fruste keratoconus (FFKc). METHODS. A retrospective comparative study was conducted involving 180 eyes. ORA preoperative data were analyzed for 125 normal control eyes (64 patients) undergoing laser in situ keratomileusis (LASIK) without corneal ectasia after 24 months of follow-up and 55 case eyes with unilateral keratoconus from a database (BCVA of 1.0, KISA index <60%). All eyes were matched in four groups of central corneal thickness (CCT): group 1, < 500 mu m; group 2, 500 to 539 mu m; group 3, 540 to 579 mu m; and group 4 > 580 mu m. Corneal hysteresis (CH), the corneal resistance factor (CRF), the air pressure curve, and the infrared signal were compared between FFKc and normal eyes in each group. RESULTS. The mean CH was 9.1 +/- 1.8 mm Hg for FFKc and 10.3 +/- 1.9 mm Hg for control eyes (P < 0.001), and the mean CRF was 9.2 +/- 1.8 and 11.1 +/- 2 mm Hg (P < 0.001), respectively. Sensitivity in each group was as follows: group 1, CH < 9.5 mm Hg (91%) and CRF < 9.5 mm Hg (81%); group 2, CH < 10.5 mm Hg (91%) and CRF < 10 mm Hg (87%); group 3, CH < 11.5 mm Hg (79%) and CRF < 11 mm Hg (74%); group 4 had two cases of FFKc, and the difference was not significant. Air pressure levels at inward and outward applanation and the maximum air pressure level were significantly lower and shorter in time in FFKc (P < 0.001), whereas the shape of the infrared signal was more variable. CONCLUSIONS. The ORA provides additional information in the screening of FFKc, with an accurate analysis of the corneal biomechanical properties according to CCT, air pressure, and infrared curves. (Invest Ophthalmol Vis Sci. 2010;51:2403-2410) DOI: 10.1167/iovs.09-3689
引用
收藏
页码:2403 / 2410
页数:8
相关论文
共 50 条
  • [1] The Role of Ocular Response Analyzer in Differentiation of Forme Fruste Keratoconus From Corneal Astigmatism
    Kirgiz, Ahmet
    Erdur, Sevil Karaman
    Atalay, Kursat
    Gurez, Ceren
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2019, 45 (02): : 83 - 87
  • [2] Discriminant Value of Custom Ocular Response Analyzer Waveform Derivatives in Forme Fruste Keratoconus
    Luz, Allan
    Lopes, Bernardo
    Hallahan, Katie M.
    Valbon, Bruno
    Fontes, Bruno
    Schor, Paulo
    Dupps, William J., Jr.
    Ambrosio, Renato, Jr.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 164 : 14 - 21
  • [3] Ocular, corneal, and internal aberrations in eyes with keratoconus, forme fruste keratoconus, and healthy eyes
    Mohammad Naderan
    Ali Jahanrad
    Mahgol Farjadnia
    International Ophthalmology, 2018, 38 : 1565 - 1573
  • [4] Ocular, corneal, and internal aberrations in eyes with keratoconus, forme fruste keratoconus, and healthy eyes
    Naderan, Mohammad
    Jahanrad, Ali
    Farjadnia, Mahgol
    INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (04) : 1565 - 1573
  • [5] A Systematic Review of Subclinical Keratoconus and Forme Fruste Keratoconus
    Henriquez, Maria A.
    Hadid, Marta
    Izquierdo, Luis, Jr.
    JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (04) : 270 - +
  • [6] Biomechanical properties analysis of forme fruste keratoconus and subclinical keratoconus
    Yan Huo
    Xuan Chen
    Huazheng Cao
    Jing Li
    Jie Hou
    Yan Wang
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 1311 - 1320
  • [7] Biomechanical properties analysis of forme fruste keratoconus and subclinical keratoconus
    Huo, Yan
    Chen, Xuan
    Cao, Huazheng
    Li, Jing
    Hou, Jie
    Wang, Yan
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (05) : 1311 - 1320
  • [8] Comparison of corneal shape and ocular aberrations in eyes with forme fruste keratoconus to that of normal cornea
    Ueki, Ryotaro
    Maeda, Naoyuki
    Fuchihata, Mutsumi
    Koh, Shizuka
    Kitaoka, Takashi
    Nishida, Kohji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [9] A Potential Screening Index of Corneal Biomechanics in Healthy Subjects, Forme Fruste Keratoconus Patients and Clinical Keratoconus Patients
    Tian, Lei
    Qin, Xiao
    Zhang, Hui
    Zhang, Di
    Guo, Li-Li
    Zhang, Hai-Xia
    Wu, Ying
    Jie, Ying
    Li, Lin
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [10] Corneal and Total Aberrations in Patients With Fruste Forme Keratoconus
    Schlegel, Z.
    Gatinel, D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)