Screening of Forme Fruste Keratoconus with the Ocular Response Analyzer

被引:99
|
作者
Schweitzer, Cedric [1 ]
Roberts, Cynthia J. [2 ]
Mahmoud, Ashraf M. [2 ]
Colin, Joseph [1 ]
Maurice-Tison, Sylvie [1 ]
Kerautret, Julien [1 ]
机构
[1] Univ Hosp Pellegrin, Dept Ophthalmol, Natl Reference Ctr Keratoconus, Bordeaux, France
[2] Ohio State Univ, Dept Biomed Engn Ophthalmol & Surg, Columbus, OH 43210 USA
关键词
IN-SITU KERATOMILEUSIS; CENTRAL CORNEAL THICKNESS; ACADEMY-OF-OPHTHALMOLOGY; WAVE-FRONT ABERRATIONS; RESIDUAL STROMAL BED; BIOMECHANICAL PROPERTIES; REFRACTIVE SURGERY; FEMTOSECOND LASER; UNILATERAL KERATOCONUS; INTRAOCULAR-PRESSURE;
D O I
10.1167/iovs.09-3689
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To evaluate the performance of the Ocular Response Analyzer (ORA) in the screening of forme fruste keratoconus (FFKc). METHODS. A retrospective comparative study was conducted involving 180 eyes. ORA preoperative data were analyzed for 125 normal control eyes (64 patients) undergoing laser in situ keratomileusis (LASIK) without corneal ectasia after 24 months of follow-up and 55 case eyes with unilateral keratoconus from a database (BCVA of 1.0, KISA index <60%). All eyes were matched in four groups of central corneal thickness (CCT): group 1, < 500 mu m; group 2, 500 to 539 mu m; group 3, 540 to 579 mu m; and group 4 > 580 mu m. Corneal hysteresis (CH), the corneal resistance factor (CRF), the air pressure curve, and the infrared signal were compared between FFKc and normal eyes in each group. RESULTS. The mean CH was 9.1 +/- 1.8 mm Hg for FFKc and 10.3 +/- 1.9 mm Hg for control eyes (P < 0.001), and the mean CRF was 9.2 +/- 1.8 and 11.1 +/- 2 mm Hg (P < 0.001), respectively. Sensitivity in each group was as follows: group 1, CH < 9.5 mm Hg (91%) and CRF < 9.5 mm Hg (81%); group 2, CH < 10.5 mm Hg (91%) and CRF < 10 mm Hg (87%); group 3, CH < 11.5 mm Hg (79%) and CRF < 11 mm Hg (74%); group 4 had two cases of FFKc, and the difference was not significant. Air pressure levels at inward and outward applanation and the maximum air pressure level were significantly lower and shorter in time in FFKc (P < 0.001), whereas the shape of the infrared signal was more variable. CONCLUSIONS. The ORA provides additional information in the screening of FFKc, with an accurate analysis of the corneal biomechanical properties according to CCT, air pressure, and infrared curves. (Invest Ophthalmol Vis Sci. 2010;51:2403-2410) DOI: 10.1167/iovs.09-3689
引用
收藏
页码:2403 / 2410
页数:8
相关论文
共 50 条
  • [21] Bilateral severe keratoconus after laser in situ keratomileusis in a patient with forme fruste keratoconus
    Lafond, G
    Bazin, R
    Lajoie, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (07): : 1115 - 1118
  • [22] Combined corneal biomechanical and tomographical indices in subclinical and forme fruste keratoconus
    Ganesh, Meghna
    Arora, Ritu
    Titiyal, Jeewan S.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (09)
  • [23] Multifocal Toric Intraocular Lens Implantation for Forme Fruste and Stable Keratoconus
    Montano, Margarita
    Lopez-Dorantes, Karla P.
    Ramirez-Miranda, Arturo
    Graue-Hernandez, Enrique O.
    Navas, Alejandro
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (04) : 282 - 285
  • [24] Enhanced Combined Tomography and Biomechanics Data for Distinguishing Forme Fruste Keratoconus
    Luz, Allan
    Lopes, Bernardo
    Hallahan, Katie M.
    Valbon, Bruno
    Ramos, Isaac
    Faria-Correia, Fernando
    Schor, Paulo
    Dupps, William J., Jr.
    Ambrosio, Renato, Jr.
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (07) : 479 - +
  • [25] Evidence of corneal ectasia susceptibility: a new definition of forme fruste keratoconus
    Koh, Shizuka
    Ambrosio, Renato, Jr.
    Maeda, Naoyuki
    Nishida, Kohji
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (11): : 1570 - 1572
  • [26] Corneal biomechanical properties and anterior segment parameters in forme fruste keratoconus
    Kozobolis, Vassilios
    Sideroudi, Haris
    Giarmoukakis, Athanassios
    Gkika, Maria
    Labiris, Georgios
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (06) : 920 - 930
  • [27] Combining Placido and Corneal Wavefront Data for the Detection of Forme Fruste Keratoconus
    Saad, Alain
    Gatinel, Damien
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (08) : 510 - 516
  • [28] Astigmatic vector analysis after combined surgery for forme fruste keratoconus
    Ayhan Sağlık
    Ali Şimşek
    International Ophthalmology, 45 (1)
  • [29] "A forme fruste of a forme fruste": the most minimal expression of a cleft?
    Mukund Jagannathan
    Manohar Vellury
    Sunita More
    Milind Wagh
    European Journal of Plastic Surgery, 2002, 25 (6) : 339 - 340
  • [30] A potential screening index of corneal biomechanics in healthy subjects, forme fruste keratoconus patients and clinical keratoconus patients (vol 9, 766605, 2021)
    Tian, Lei
    Qin, Xiao
    Zhang, Hui
    Zhang, Di
    Guo, Li-Li
    Zhang, Hai-Xia
    Wu, Ying
    Jie, Ying
    Li, Lin
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10