A voltammetric sensor based on eosin Y film modified glassy carbon electrode for simultaneous determination of hydroquinone and catechol

被引:44
|
作者
He, Jiahong [1 ,2 ,3 ]
Qiu, Ri [2 ]
Li, Wenpo [1 ]
Xing, Shaohua [2 ]
Song, Zhongrong [3 ]
Li, Qiang [3 ]
Zhang, Shengtao [1 ]
机构
[1] Chongqing Univ, Sch Chem & Chem Engn, Chongqing 400044, Peoples R China
[2] Luoyang Ship Mat Res Inst, State Key Lab Marine Corros & Protect, Qingdao 266101, Peoples R China
[3] Chongqing Univ Arts & Sci, Sch Mat & Chem Engn, Yongchuan 402160, Peoples R China
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; IONIC LIQUID; DOPED POLY(3,4-ETHYLENEDIOXYTHIOPHENE); ELECTROCHEMICAL DETERMINATION; DIHYDROXYBENZENE ISOMERS; GRAPHENE NANOCOMPOSITE; FACILE PREPARATION; COMPOSITE FILM; NANOTUBES; RESORCINOL;
D O I
10.1039/c4ay00575a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
By using cyclic voltammetry, eosin Y film was electrodeposited on the surface of glassy carbon electrode (GCE) to obtain the modified electrode (denoted as eosin Y/GCE). Scanning electron microscopy, electrochemical impedance spectroscopy and cyclic voltammetry techniques were used for the characterization of the morphological and electrochemical properties of eosin Y/GCE. The etectrocatalysis capability of eosin Y/GCE to hydroquinone (HQ) and catechol (CC) was investigated by cyclic voltammetry (CV) and differential pulse vottammetry (DPV) techniques. Compared with the bare GCE, eosin Y/GCE exhibited outstanding electrocatatytic activity and reversibility towards the oxidation of HQ and CC. The oxidation and reduction peak separation was decreased from 386 to 60 mV for HQ and from 340 to 56 mV for CC at eosin Y/GCE. The differential pulse voltammetry results showed that the oxidation peaks of the two isomers in acetate buffer solution could be clearly discriminated with a peak potential separation of ca. 106 mV, which was sufficiently wide to discriminate the two dihydroxybenzene isomers. Under optimal conditions, the oxidation peak currents were linear to HQ/CC concentration in the range from 1 mu M to 130 mu M with a detection limit of 0.14 mu M (3 sigma) for HQ and 0.12 mu M (3 sigma) for CC. Moreover, eosin Y/GCE exhibited excellent anti-interference ability, and was successfully applied to the simultaneous determination of HQ and CC in spiked water samples with reliable recovery.
引用
收藏
页码:6494 / 6503
页数:10
相关论文
共 50 条
  • [31] Electrocatalytic oxidation and simultaneous determination of catechol and hydroquinone at a novel carbon nano-fragment modified glassy carbon electrode
    Zhang, Chuyi
    Zeng, Lixuan
    Zhu, Xiaohua
    Yu, Chumei
    Zuo, Xiaoxi
    Xiao, Xin
    Nan, Junmin
    ANALYTICAL METHODS, 2013, 5 (09) : 2203 - 2208
  • [32] Nitrogen, Sulfur Dual-Doped Mesoporous Carbon Modified Glassy Carbon Electrode for Simultaneous Determination of Hydroquinone and Catechol
    Xu, Ruiyu
    Xiao, Lili
    Luo, Liang
    Yuan, Qunhui
    Qin, Danfeng
    Hu, Guangzhi
    Gan, Wei
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (13) : B617 - B623
  • [33] Voltammetric determination of dopamine using modified glassy carbon electrode by electrografting of catechol
    Pourghobadi, Zeinab
    Neamatollahi, Davood
    Journal of the Serbian Chemical Society, 2017, 82 (09): : 1053 - 1061
  • [34] Voltammetric determination of dopamine using modified glassy carbon electrode by electrografting of catechol
    Pourghobadi, Zeinab
    Neamatollahi, Davood
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2017, 82 (09) : 1053 - 1061
  • [35] Simultaneous determination of hydroquinone and catechol Using poly(p-aminobenzoic acid) modified glassy carbon electrode
    Yang, Ping
    Zhu, Qiyong
    Chen, Yonghong
    Wang, Fengwu
    Journal of Applied Polymer Science, 2009, 113 (05): : 2881 - 2886
  • [36] Glassy Carbon Electrode Modified with C/Au Nanostructured Materials for Simultaneous Determination of Hydroquinone and Catechol in Water Matrices
    Pina, Samuel
    Candia-Onfray, Christian
    Hassan, Natalia
    Jara-Ulloa, Paola
    Contreras, David
    Salazar, Ricardo
    CHEMOSENSORS, 2021, 9 (05)
  • [37] Simultaneous Determination of Hydroquinone, Catechol and Resorcinol at Poly(3-Thiophenemalonic Acid) Modified Glassy Carbon Electrode
    Xu, Guangri
    Tang, Bo
    Jing, Shuke
    Tao, Jianzhong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (12): : 10659 - 10667
  • [38] Simultaneous Determination of Catechol and Hydroquinone on Nano-Co/L-Cysteine Modified Glassy Carbon Electrode
    Huang, Baomei
    Yao, Chengwei
    Wang, Enyang
    Du, Shizhang
    Yang, Jing
    Lu, Xiaoquan
    ELECTROANALYSIS, 2022, 34 (02) : 405 - 414
  • [39] Simultaneous Determination of Hydroquinone and Catechol Using Poly(p-aminobenzoic acid) Modified Glassy Carbon Electrode
    Yang, Ping
    Zhu, Qiyong
    Chen, Yonghong
    Wang, Fengwu
    JOURNAL OF APPLIED POLYMER SCIENCE, 2009, 113 (05) : 2881 - 2886
  • [40] Electrooxidation of DL-norvaline at Glassy Carbon Electrode; Approaching the Modified Electrode for Voltammetric Studies of Hydroquinone and Catechol
    Kamel, Mahmoud M.
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2014, 5 (01) : 23 - 31