A voltammetric sensor based on eosin Y film modified glassy carbon electrode for simultaneous determination of hydroquinone and catechol

被引:44
|
作者
He, Jiahong [1 ,2 ,3 ]
Qiu, Ri [2 ]
Li, Wenpo [1 ]
Xing, Shaohua [2 ]
Song, Zhongrong [3 ]
Li, Qiang [3 ]
Zhang, Shengtao [1 ]
机构
[1] Chongqing Univ, Sch Chem & Chem Engn, Chongqing 400044, Peoples R China
[2] Luoyang Ship Mat Res Inst, State Key Lab Marine Corros & Protect, Qingdao 266101, Peoples R China
[3] Chongqing Univ Arts & Sci, Sch Mat & Chem Engn, Yongchuan 402160, Peoples R China
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; IONIC LIQUID; DOPED POLY(3,4-ETHYLENEDIOXYTHIOPHENE); ELECTROCHEMICAL DETERMINATION; DIHYDROXYBENZENE ISOMERS; GRAPHENE NANOCOMPOSITE; FACILE PREPARATION; COMPOSITE FILM; NANOTUBES; RESORCINOL;
D O I
10.1039/c4ay00575a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
By using cyclic voltammetry, eosin Y film was electrodeposited on the surface of glassy carbon electrode (GCE) to obtain the modified electrode (denoted as eosin Y/GCE). Scanning electron microscopy, electrochemical impedance spectroscopy and cyclic voltammetry techniques were used for the characterization of the morphological and electrochemical properties of eosin Y/GCE. The etectrocatalysis capability of eosin Y/GCE to hydroquinone (HQ) and catechol (CC) was investigated by cyclic voltammetry (CV) and differential pulse vottammetry (DPV) techniques. Compared with the bare GCE, eosin Y/GCE exhibited outstanding electrocatatytic activity and reversibility towards the oxidation of HQ and CC. The oxidation and reduction peak separation was decreased from 386 to 60 mV for HQ and from 340 to 56 mV for CC at eosin Y/GCE. The differential pulse voltammetry results showed that the oxidation peaks of the two isomers in acetate buffer solution could be clearly discriminated with a peak potential separation of ca. 106 mV, which was sufficiently wide to discriminate the two dihydroxybenzene isomers. Under optimal conditions, the oxidation peak currents were linear to HQ/CC concentration in the range from 1 mu M to 130 mu M with a detection limit of 0.14 mu M (3 sigma) for HQ and 0.12 mu M (3 sigma) for CC. Moreover, eosin Y/GCE exhibited excellent anti-interference ability, and was successfully applied to the simultaneous determination of HQ and CC in spiked water samples with reliable recovery.
引用
收藏
页码:6494 / 6503
页数:10
相关论文
共 50 条
  • [21] A glassy carbon electrode modified with cerium phosphate nanotubes for the simultaneous determination of hydroquinone, catechol and resorcinol
    Zhen Li
    Yuhua Yue
    Yanjun Hao
    Shun Feng
    Xianli Zhou
    Microchimica Acta, 2018, 185
  • [22] Highly sensitive and simultaneous determination of hydroquinone and catechol at poly(thionine) modified glassy carbon electrode
    Ahammad, A. J. Saleh
    Rahman, Md Mahbubur
    Xu, Guang-Ri
    Kim, Sunghyun
    Lee, Jae-Joon
    ELECTROCHIMICA ACTA, 2011, 56 (14) : 5266 - 5271
  • [23] Simultaneous Determination of Catechol and Hydroquinone at a Carbon Nanotubes Modified Electrode
    Yang Shao-Ming
    Wei Zhi-Peng
    Hu Guang-Hui
    Jiang Dan
    Huang Ai-Hua
    Zheng Long-Zhen
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2010, 31 (02): : 264 - 268
  • [24] A graphene oxide-mesoporous MnO2 nanocomposite modified glassy carbon electrode as a novel and efficient voltammetric sensor for simultaneous determination of hydroquinone and catechol
    Gan, Tian
    Sun, Junyong
    Huang, Kejing
    Song, Li
    Li, Youmei
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 177 : 412 - 418
  • [25] Covalent modification of a glassy carbon electrode with penicillamine for simultaneous determination of hydroquinone and catechol
    Liang Wang
    Peng Fei Huang
    Jun Yue Bai
    Hong Jing Wang
    Li Ying Zhang
    Yu Qing Zhao
    Microchimica Acta, 2007, 158 : 151 - 157
  • [26] Covalent modification of a glassy carbon electrode with penicillamine for simultaneous determination of hydroquinone and catechol
    Wang, Liang
    Huang, Peng Fei
    Bai, Jun Yue
    Wang, Hong Jing
    Zhang, Li Ying
    Zhao, Yu Qing
    MICROCHIMICA ACTA, 2007, 158 (1-2) : 151 - 157
  • [27] Direct simultaneous electrochemical determination of hydroquinone and catechol at a poly(glutamic acid) modified glassy carbon electrode
    Wang, Liang
    Huang, Pengfei
    Bai, Junyue
    Wang, Hongjing
    Zhang, Liying
    Zhao, Yuqing
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2007, 2 (01): : 123 - 132
  • [28] Simultaneous electrochemical determination of catechol and hydroquinone based on graphene-TiO2 nanocomposite modified glassy carbon electrode
    Zhang, Yanli
    Xie, Jinling
    Xiao, Shixiu
    Yang, Zhongming
    Pang, Pengfei
    Gao, Yuntao
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 204 : 102 - 108
  • [29] Simultaneous determination of catechol and hydroquinone based on poly (diallyldimethylammonium chloride) functionalized graphene-modified glassy carbon electrode
    Letao Wang
    Yan Zhang
    Yongling Du
    Daban Lu
    Yuzhen Zhang
    Chunming Wang
    Journal of Solid State Electrochemistry, 2012, 16 : 1323 - 1331
  • [30] Simultaneous determination of catechol and hydroquinone based on poly (diallyldimethylammonium chloride) functionalized graphene-modified glassy carbon electrode
    Wang, Letao
    Zhang, Yan
    Du, Yongling
    Lu, Daban
    Zhang, Yuzhen
    Wang, Chunming
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (04) : 1323 - 1331