Simultaneous determination of hydroquinone and catechol Using poly(p-aminobenzoic acid) modified glassy carbon electrode

被引:0
|
作者
Yang, Ping [1 ]
Zhu, Qiyong [1 ]
Chen, Yonghong [1 ]
Wang, Fengwu [1 ]
机构
[1] Department of Chemistry, Huainan Normal University, HuainanAnhui Province 243031, China
来源
Journal of Applied Polymer Science | 2009年 / 113卷 / 05期
关键词
The electrochemical redox reaction of hydroquinone (HQ) and catechol (CC)was investigated with poly-(p-aminobenzoic acid) modified glassy-carbon electrode (poly-p-ABA/GCE) via cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The poly-p- ABA/GCE has shown an excellent electrocatalytic activity for HQ and CC in 0.1 mol L-1 phosphate buffer solution (PBS). The oxidation and reduction separation (ΔE) has been decreased from 353 to 32 mV for HQ and from 228 to 33 mV vs. SCE for CC at the bare GCE and poly-p-ABA/ GCE respectively. DPV curves show that the oxidation potential of HQ and CC has a separation about 105 mV at the poly-p-ABA/GCE. Moreover; the oxidation current of HQ and CC has been enhanced two and four times respectively at the modified electrode. Using DPV method; a highly selective and simultaneous determination of HQ and CC has been explored at the poly-p-ABA/ GCE. © 2009 Wiley Periodicals; Inc. J Appl Polym Sci 113: 2881-2886; 2009;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
页码:2881 / 2886
相关论文
共 50 条
  • [1] Simultaneous Determination of Hydroquinone and Catechol Using Poly(p-aminobenzoic acid) Modified Glassy Carbon Electrode
    Yang, Ping
    Zhu, Qiyong
    Chen, Yonghong
    Wang, Fengwu
    JOURNAL OF APPLIED POLYMER SCIENCE, 2009, 113 (05) : 2881 - 2886
  • [2] Direct simultaneous electrochemical determination of hydroquinone and catechol at a poly(glutamic acid) modified glassy carbon electrode
    Wang, Liang
    Huang, Pengfei
    Bai, Junyue
    Wang, Hongjing
    Zhang, Liying
    Zhao, Yuqing
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2007, 2 (01): : 123 - 132
  • [3] Preparation of Poly-(p-aminobenzoic acid)/Multiwall Carbon Nanotubes Composite Film Modified Glassy Carbon Electrode and Application to Detect Catechol and Hydroquinone Simultaneously
    Qu, Jianying
    Lou, Tongfang
    Kang, Shiping
    Du, Xueping
    ELECTROCHEMISTRY, 2013, 81 (02) : 82 - 85
  • [4] Simultaneous Determination of Hydroquinone, Catechol and Resorcinol at Poly(3-Thiophenemalonic Acid) Modified Glassy Carbon Electrode
    Xu, Guangri
    Tang, Bo
    Jing, Shuke
    Tao, Jianzhong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (12): : 10659 - 10667
  • [6] Simultaneous Determination of Hydroquinone and Catechol at Poly-histidine Film Modified Glassy Carbon Electrode
    Yang, Qiu-xia
    Sui, Wei-ping
    Fan, Da-wei
    Li, Guo-bao
    ADVANCES IN CHEMICAL ENGINEERING III, PTS 1-4, 2013, 781-784 : 89 - 92
  • [7] Highly sensitive and simultaneous determination of hydroquinone and catechol at poly(thionine) modified glassy carbon electrode
    Ahammad, A. J. Saleh
    Rahman, Md Mahbubur
    Xu, Guang-Ri
    Kim, Sunghyun
    Lee, Jae-Joon
    ELECTROCHIMICA ACTA, 2011, 56 (14) : 5266 - 5271
  • [8] Simultaneous determination of hydroquinone and catechol at a glassy carbon electrode modified with multiwall carbon nanotubes
    Qi, HL
    Zhang, CX
    ELECTROANALYSIS, 2005, 17 (10) : 832 - 838
  • [9] Voltammetric determination of catechol and hydroquinone at poly (murexide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Rani, T. Shobha
    Ganesh, P. S.
    Raj, Y. Paul
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 98 : 746 - 752
  • [10] Voltammetric determination of catechol and hydroquinone at poly (niacinamide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Ganesh, P. S.
    Rani, T. Shobha
    Reddy, G. Venkata
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 : 505 - 511