Voltammetric determination of catechol and hydroquinone at poly (murexide) modified glassy carbon electrode

被引:54
|
作者
Kumar, A. Anil [1 ]
Swamy, B. E. Kumara [2 ]
Rani, T. Shobha [1 ]
Ganesh, P. S. [2 ]
Raj, Y. Paul [1 ]
机构
[1] Dravidian Univ, Dept Chem, Kuppam 517425, Andhra Pradesh, India
[2] Kuvempu Univ, Dept PG Studies & Res Ind Chem, Shimoga 577451, Karnataka, India
关键词
Catechol (CC); Hydroquinone (HQ); Glassy carbon electrode (GCE); Electropolymerization; Cyclic voltammetry (CV); SIMULTANEOUS ELECTROCHEMICAL DETERMINATION; REDUCED GRAPHENE OXIDE; PASTE ELECTRODE; SIMULTANEOUS ELECTROANALYSIS; IONIC LIQUID; FILM; NANOTUBES; BEHAVIOR; SENSOR; POLYMERIZATION;
D O I
10.1016/j.msec.2018.12.055
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The electrochemical study of Catechol (CC) was studied in presence of Hydroquinone (HQ) using poly(murexide) modified glassy carbon electrode (MGCE) by cyclic voltammetric study. The modified electrode exhibited good affirmative response towards the electro chemical oxidation of CC in presence of HQ in 0.2 M phosphate buffer solution at the physiological of pH 7.4. The influence of scan rate, concentration and pH parameters were examined with the cyclic voltammetric method. The modified electrode showed good selectivity and sensitivity with an advantage of interference study and free determination of selected analytes in this experiment. Finally a simple, sensitive and selective method was developed for the determination of dihydroxybenzene isomeric compounds.
引用
收藏
页码:746 / 752
页数:7
相关论文
共 50 条
  • [1] Voltammetric determination of catechol and hydroquinone at poly (niacinamide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Ganesh, P. S.
    Rani, T. Shobha
    Reddy, G. Venkata
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 : 505 - 511
  • [2] Poly (glycine) modified carbon paste electrode for simultaneous determination of catechol and hydroquinone: A voltammetric study
    Harisha, K. V.
    Swamy, B. E. Kumara
    Ebenso, Eno E.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 823 : 730 - 736
  • [4] Simultaneous Determination of Hydroquinone and Catechol at Poly-histidine Film Modified Glassy Carbon Electrode
    Yang, Qiu-xia
    Sui, Wei-ping
    Fan, Da-wei
    Li, Guo-bao
    ADVANCES IN CHEMICAL ENGINEERING III, PTS 1-4, 2013, 781-784 : 89 - 92
  • [5] Highly sensitive and simultaneous determination of hydroquinone and catechol at poly(thionine) modified glassy carbon electrode
    Ahammad, A. J. Saleh
    Rahman, Md Mahbubur
    Xu, Guang-Ri
    Kim, Sunghyun
    Lee, Jae-Joon
    ELECTROCHIMICA ACTA, 2011, 56 (14) : 5266 - 5271
  • [6] A voltammetric sensor based on eosin Y film modified glassy carbon electrode for simultaneous determination of hydroquinone and catechol
    He, Jiahong
    Qiu, Ri
    Li, Wenpo
    Xing, Shaohua
    Song, Zhongrong
    Li, Qiang
    Zhang, Shengtao
    ANALYTICAL METHODS, 2014, 6 (16) : 6494 - 6503
  • [7] Direct simultaneous electrochemical determination of hydroquinone and catechol at a poly(glutamic acid) modified glassy carbon electrode
    Wang, Liang
    Huang, Pengfei
    Bai, Junyue
    Wang, Hongjing
    Zhang, Liying
    Zhao, Yuqing
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2007, 2 (01): : 123 - 132
  • [8] Simultaneous determination of hydroquinone and catechol at a glassy carbon electrode modified with multiwall carbon nanotubes
    Qi, HL
    Zhang, CX
    ELECTROANALYSIS, 2005, 17 (10) : 832 - 838
  • [9] A voltammetric sensor based on electrochemically activated glassy carbon electrode for simultaneous determination of hydroquinone and catechol
    Kong, Yong
    Chen, Xiaohui
    Yao, Chao
    Ma, Mengjie
    Chen, Zhidong
    ANALYTICAL METHODS, 2011, 3 (09) : 2121 - 2126
  • [10] Voltammetric determination of dopamine using modified glassy carbon electrode by electrografting of catechol
    Pourghobadi, Zeinab
    Neamatollahi, Davood
    Journal of the Serbian Chemical Society, 2017, 82 (09): : 1053 - 1061