A voltammetric sensor based on eosin Y film modified glassy carbon electrode for simultaneous determination of hydroquinone and catechol

被引:44
|
作者
He, Jiahong [1 ,2 ,3 ]
Qiu, Ri [2 ]
Li, Wenpo [1 ]
Xing, Shaohua [2 ]
Song, Zhongrong [3 ]
Li, Qiang [3 ]
Zhang, Shengtao [1 ]
机构
[1] Chongqing Univ, Sch Chem & Chem Engn, Chongqing 400044, Peoples R China
[2] Luoyang Ship Mat Res Inst, State Key Lab Marine Corros & Protect, Qingdao 266101, Peoples R China
[3] Chongqing Univ Arts & Sci, Sch Mat & Chem Engn, Yongchuan 402160, Peoples R China
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; IONIC LIQUID; DOPED POLY(3,4-ETHYLENEDIOXYTHIOPHENE); ELECTROCHEMICAL DETERMINATION; DIHYDROXYBENZENE ISOMERS; GRAPHENE NANOCOMPOSITE; FACILE PREPARATION; COMPOSITE FILM; NANOTUBES; RESORCINOL;
D O I
10.1039/c4ay00575a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
By using cyclic voltammetry, eosin Y film was electrodeposited on the surface of glassy carbon electrode (GCE) to obtain the modified electrode (denoted as eosin Y/GCE). Scanning electron microscopy, electrochemical impedance spectroscopy and cyclic voltammetry techniques were used for the characterization of the morphological and electrochemical properties of eosin Y/GCE. The etectrocatalysis capability of eosin Y/GCE to hydroquinone (HQ) and catechol (CC) was investigated by cyclic voltammetry (CV) and differential pulse vottammetry (DPV) techniques. Compared with the bare GCE, eosin Y/GCE exhibited outstanding electrocatatytic activity and reversibility towards the oxidation of HQ and CC. The oxidation and reduction peak separation was decreased from 386 to 60 mV for HQ and from 340 to 56 mV for CC at eosin Y/GCE. The differential pulse voltammetry results showed that the oxidation peaks of the two isomers in acetate buffer solution could be clearly discriminated with a peak potential separation of ca. 106 mV, which was sufficiently wide to discriminate the two dihydroxybenzene isomers. Under optimal conditions, the oxidation peak currents were linear to HQ/CC concentration in the range from 1 mu M to 130 mu M with a detection limit of 0.14 mu M (3 sigma) for HQ and 0.12 mu M (3 sigma) for CC. Moreover, eosin Y/GCE exhibited excellent anti-interference ability, and was successfully applied to the simultaneous determination of HQ and CC in spiked water samples with reliable recovery.
引用
收藏
页码:6494 / 6503
页数:10
相关论文
共 50 条
  • [1] Voltammetric resolution of catechol and hydroquinone at eosin Y film modified carbon paste electrode
    Ganesh, P. S.
    Swamy, B. E. Kumara
    JOURNAL OF MOLECULAR LIQUIDS, 2016, 220 : 208 - 215
  • [2] A voltammetric sensor based on electrochemically activated glassy carbon electrode for simultaneous determination of hydroquinone and catechol
    Kong, Yong
    Chen, Xiaohui
    Yao, Chao
    Ma, Mengjie
    Chen, Zhidong
    ANALYTICAL METHODS, 2011, 3 (09) : 2121 - 2126
  • [3] A voltammetric sensor based on graphene-modified electrode for simultaneous determination of catechol and hydroquinone
    Du, Haijun
    Ye, Jianshan
    Zhang, Jiaqi
    Huang, Xiaodan
    Yu, Chengzhong
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 650 (02) : 209 - 213
  • [4] Voltammetric determination of catechol and hydroquinone at poly (murexide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Rani, T. Shobha
    Ganesh, P. S.
    Raj, Y. Paul
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 98 : 746 - 752
  • [5] Voltammetric determination of catechol and hydroquinone at poly (niacinamide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Ganesh, P. S.
    Rani, T. Shobha
    Reddy, G. Venkata
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 : 505 - 511
  • [6] Simultaneous Determination of Hydroquinone and Catechol at Poly-histidine Film Modified Glassy Carbon Electrode
    Yang, Qiu-xia
    Sui, Wei-ping
    Fan, Da-wei
    Li, Guo-bao
    ADVANCES IN CHEMICAL ENGINEERING III, PTS 1-4, 2013, 781-784 : 89 - 92
  • [7] Simultaneous determination of hydroquinone and catechol at PASA/MWNTs composite film modified glassy carbon electrode
    Zhao, Dong-Ming
    Zhang, Xiu-Hua
    Feng, Li-Jun
    Jia, Li
    Wang, Sheng-Fu
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 74 (01) : 317 - 321
  • [8] Simultaneous Determination of Catechol and Hydroquinone Based on Fluorinated Graphite Modified Glassy Carbon Electrode
    Ma Zhen-Hua
    Wang Hui-Cai
    Yao Xiao-Xia
    Liu Ming-Qiang
    Ma Yu-Qiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (12) : 1906 - 1912
  • [9] Simultaneous determination of hydroquinone and catechol at a glassy carbon electrode modified with multiwall carbon nanotubes
    Qi, HL
    Zhang, CX
    ELECTROANALYSIS, 2005, 17 (10) : 832 - 838
  • [10] Electrochemical Determination of Hydroquinone and Catechol Using Multi-walled Carbon Nanotubes/eosin Y Modified Glassy Carbon Electrode
    Zheng, Shengbiao
    Liu, Jing
    Liu, Renhao
    Hui, Zhenzhen
    Tang, Jing
    Wang, Xuchun
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (07): : 6234 - 6246