Voltammetric determination of dopamine using modified glassy carbon electrode by electrografting of catechol

被引:18
|
作者
Pourghobadi, Zeinab [1 ]
Neamatollahi, Davood [2 ]
机构
[1] Islamic Azad Univ, Dept Chem, Khorramabad Branch, Khorramabad, Iran
[2] Bu Ali Sina Univ, Dept Chem, Fac Sci, Hamadan, Iran
关键词
electrografted glassy carbon electrode; dopamine; catechol; cyclic voltammetry; electrochemical sensor; ASCORBIC-ACID; ELECTROCHEMICAL DETECTION; URIC-ACID; LIQUID-CHROMATOGRAPHY; GOLD ELECTRODE; NANOPARTICLES; MEDIATOR; SENSOR;
D O I
10.2298/JSC161219076P
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
By means of cyclic voltammetry as a diagnostic technique, the present study tried to describe the behaviour of dopamine (DP) at the bare and catechol electrografted glassy carbon electrode (CA/GCE). The results indicated that the CA/GCE exhibits high electrocatalytic activity toward DP. The DP cycling of the CA/GCE in DP showed two linear calibration ranges between 5.0-100 and 100-750 mu M with a detection limit of 0.86 mu M. For 6 DP replicate measurements (50 mu M); the relative standard deviation (RSD) was 2.7 %. This method was successfully used for the determination of DP in serum samples.
引用
收藏
页码:1053 / 1061
页数:9
相关论文
共 50 条
  • [1] Voltammetric determination of dopamine using modified glassy carbon electrode by electrografting of catechol
    Pourghobadi, Zeinab
    Neamatollahi, Davood
    Journal of the Serbian Chemical Society, 2017, 82 (09): : 1053 - 1061
  • [2] Voltammetric Determination of Dopamine in the Presence of Caffeine Using a Modified Glassy Carbon Electrode
    Surface Engineering and Applied Electrochemistry, 2023, 59 : 634 - 643
  • [3] Voltammetric Determination of Dopamine in the Presence of Caffeine Using a Modified Glassy Carbon Electrode
    Ebrahimi, Maryam
    Beitollahi, Hadi
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2023, 59 (05) : 634 - 643
  • [4] Voltammetric determination of catechol and hydroquinone at poly (murexide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Rani, T. Shobha
    Ganesh, P. S.
    Raj, Y. Paul
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 98 : 746 - 752
  • [5] Voltammetric determination of catechol and hydroquinone at poly (niacinamide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Ganesh, P. S.
    Rani, T. Shobha
    Reddy, G. Venkata
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 : 505 - 511
  • [6] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Beigmoradi, Fariba
    Beitollahi, Hadi
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2024, 60 (01) : 15 - 23
  • [7] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Surface Engineering and Applied Electrochemistry, 2024, 60 : 15 - 23
  • [8] Simultaneous voltammetric determination of dopamine and adenosine using a single walled carbon nanotube - Modified glassy carbon electrode
    Goyal, Rajendra N.
    Singh, Sudhanshu P.
    CARBON, 2008, 46 (12) : 1556 - 1562
  • [9] Voltammetric determination of dopamine in human serum with amphiphilic chitosan modified glassy carbon electrode
    Wang, Cheng Yin
    Wang, Zhi Xian
    Zhu, Ai Ping
    Hu, Xiao Ya
    SENSORS, 2006, 6 (11) : 1523 - 1536
  • [10] Voltammetric Determination of Epinephrine using a Thiourea Modified Glassy Carbon Electrode
    Yazdely, Malihe Ahmadian
    Taher, Mohammad Ali
    Tajik, Somayeh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (04): : 517 - 527