Monitoring of heart rate and inter-beat intervals with wrist plethysmography in patients with atrial fibrillation

被引:46
|
作者
Harju, Jarkko [1 ]
Tarniceriu, Adrian [2 ]
Parak, Jakub [3 ,4 ]
Vehkaoja, Antti [3 ,4 ]
Yli-Hankala, Arvi [1 ,5 ]
Korhonen, Ilkka [3 ,4 ]
机构
[1] Tampere Univ Hosp, Dept Anesthesia, Tampere, Finland
[2] PulseOn SA, Neuchatel, Switzerland
[3] Tampere Univ Technol, Tampere, Finland
[4] Pulseon Oy, Espoo, Finland
[5] Univ Tampere, Med Sch, Tampere, Finland
关键词
heart rate; pulse rate; photoplethysmography; atrial fibrillation; perioperative monitoring; RATE-VARIABILITY; ACCURACY; PREVALENCE; FAILURE; WORN;
D O I
10.1088/1361-6579/aac9a9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective: Atrial fibrillation (AF) causes marked risk for patients, while silent fibrillation may remain unnoticed if not suspected and screened. Development of comfortable yet accurate beat-to-beat heart rate (HR) monitoring with good AF detection sensitivity would facilitate screening and improve treatment. The purpose of this study was to evaluate whether a wrist-worn photoplethysmography (PPG) device can be used to monitor beat-to-beat HR accurately during post-operative treatment in patients suffering from AF and whether wrist-PPG can be used to distinguish AF from sinus rhythm (SR). Approach: Twenty-nine patients (14 with AF, 15 with SR, mean age 71.5 years) with multiple comorbidities were monitored during routine post-operative treatment. The monitoring included standard ECG, finger PPG monitoring and a wrist-worn PPG monitor with green and infrared light sources. The HR from PPG sensors was compared against ECG-derived HR. Main results: The wrist PPG technology had very good HR and beat detection accuracy when using green light. For the SR group, the mean absolute error (MAE) for HR was 1.50 bpm, and for the interbeat intervals (IBI), the MAE was 7.64 ms. For the AF group, the MAE for HR was 4.28 bpm and for IBI, the MAE was 14.67 ms. Accuracy for the infrared (IR) channel was worse. Finger PPG provided similar accuracy for HR and better accuracy for the IBI. AF detection sensitivity using green light was 99.0% and the specificity was 93.0%. Performance can be improved by discarding unreliable IBI periods. Significance: Results suggest that wrist PPG measurement allows accurate HR and beat-to-beat HR monitoring also in AF patients, and could be used for differentiating between SR and AF with very good sensitivity.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Multiscale Distribution Entropy Analysis of Heart Rate Variability Using Differential Inter-Beat Intervals
    Lee, Dae-Young
    Choi, Young-Seok
    IEEE ACCESS, 2020, 8 : 48761 - 48773
  • [2] PLASMA DIGOXIN LEVELS AND INTER-BEAT INTERVAL SIGNAL IN ATRIAL-FIBRILLATION
    PENCHAS, S
    ZAJICEK, G
    ZEITSCHRIFT FUR KARDIOLOGIE, 1978, 67 (02): : 104 - 108
  • [3] Effect of Missing Inter-Beat Interval Data on Heart Rate Variability Analysis Using Wrist-Worn Wearables
    Baek, Hyun Jae
    Shin, JaeWook
    JOURNAL OF MEDICAL SYSTEMS, 2017, 41 (10)
  • [4] Effect of Missing Inter-Beat Interval Data on Heart Rate Variability Analysis Using Wrist-Worn Wearables
    Hyun Jae Baek
    JaeWook Shin
    Journal of Medical Systems, 2017, 41
  • [5] Are Inter-Beat Intervals From Blood Pressure a Valid Alternative to R-R Intervals for the Multiscale Entropy Analysis of Heart Rate Variability?
    Faini, Andrea
    Parati, Gianfranco
    Castiglioni, Paolo
    2020 COMPUTING IN CARDIOLOGY, 2020,
  • [6] Real-Time Respiratory Rate Estimation using Imaging Photoplethysmography Inter-Beat Intervals
    Mirmohamadsadeghi, Leila
    Fallet, Sibylle
    Moser, Virginie
    Braun, Fabian
    Vesin, Jean-Marc
    2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43, 2016, 43 : 861 - 864
  • [7] Comparison of Polar® RS800CX heart rate monitor and electrocardiogram for measuring inter-beat intervals in healthy dogs
    Essner, Ann
    Sjostrom, Rita
    Ahlgren, Erik
    Gustas, Pia
    Edge-Hughes, Laurie
    Zetterberg, Lena
    Hellstrom, Karin
    PHYSIOLOGY & BEHAVIOR, 2015, 138 : 247 - 253
  • [8] Atrial fibrillation detection using Poincare geometry and heart beat intervals
    Rao, S. K. Shrikanth
    Kolekar, Maheshkumar H.
    Martis, Roshan Joy
    EXPERT SYSTEMS, 2023, 40 (07)
  • [9] Accuracy of a low-cost heart rate monitor for research involving inter-beat interval
    Fishel, SR
    Muth, ER
    Herron, R
    Hoover, AW
    Rand, JR
    PSYCHOPHYSIOLOGY, 2004, 41 : S72 - S72
  • [10] Development of Causal Interactions Between Systolic Blood Pressure and Inter-Beat Intervals in Adolescents
    Svacinova, J.
    Javorka, M.
    Novakova, Z.
    Zavodna, E.
    Czippelova, B.
    Honzikova, N.
    PHYSIOLOGICAL RESEARCH, 2015, 64 (06) : 821 - 829