Monitoring of heart rate and inter-beat intervals with wrist plethysmography in patients with atrial fibrillation

被引:46
|
作者
Harju, Jarkko [1 ]
Tarniceriu, Adrian [2 ]
Parak, Jakub [3 ,4 ]
Vehkaoja, Antti [3 ,4 ]
Yli-Hankala, Arvi [1 ,5 ]
Korhonen, Ilkka [3 ,4 ]
机构
[1] Tampere Univ Hosp, Dept Anesthesia, Tampere, Finland
[2] PulseOn SA, Neuchatel, Switzerland
[3] Tampere Univ Technol, Tampere, Finland
[4] Pulseon Oy, Espoo, Finland
[5] Univ Tampere, Med Sch, Tampere, Finland
关键词
heart rate; pulse rate; photoplethysmography; atrial fibrillation; perioperative monitoring; RATE-VARIABILITY; ACCURACY; PREVALENCE; FAILURE; WORN;
D O I
10.1088/1361-6579/aac9a9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective: Atrial fibrillation (AF) causes marked risk for patients, while silent fibrillation may remain unnoticed if not suspected and screened. Development of comfortable yet accurate beat-to-beat heart rate (HR) monitoring with good AF detection sensitivity would facilitate screening and improve treatment. The purpose of this study was to evaluate whether a wrist-worn photoplethysmography (PPG) device can be used to monitor beat-to-beat HR accurately during post-operative treatment in patients suffering from AF and whether wrist-PPG can be used to distinguish AF from sinus rhythm (SR). Approach: Twenty-nine patients (14 with AF, 15 with SR, mean age 71.5 years) with multiple comorbidities were monitored during routine post-operative treatment. The monitoring included standard ECG, finger PPG monitoring and a wrist-worn PPG monitor with green and infrared light sources. The HR from PPG sensors was compared against ECG-derived HR. Main results: The wrist PPG technology had very good HR and beat detection accuracy when using green light. For the SR group, the mean absolute error (MAE) for HR was 1.50 bpm, and for the interbeat intervals (IBI), the MAE was 7.64 ms. For the AF group, the MAE for HR was 4.28 bpm and for IBI, the MAE was 14.67 ms. Accuracy for the infrared (IR) channel was worse. Finger PPG provided similar accuracy for HR and better accuracy for the IBI. AF detection sensitivity using green light was 99.0% and the specificity was 93.0%. Performance can be improved by discarding unreliable IBI periods. Significance: Results suggest that wrist PPG measurement allows accurate HR and beat-to-beat HR monitoring also in AF patients, and could be used for differentiating between SR and AF with very good sensitivity.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Atrial Fibrillation Detection using Photo-plethysmography and Acceleration Data at the Wrist
    Bonomi, Alberto G.
    Schipper, Fons
    Eerikainen, Linda M.
    Margarito, Jenny
    Aarts, Ronald M.
    Babaeizadeh, Saeed
    de Morree, Helma M.
    Dekker, Lukas
    2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43, 2016, 43 : 277 - 280
  • [22] Artificial-intelligence-based risk prediction and mechanism discovery for atrial fibrillation using heart beat-to-beat intervals
    Lin, Fan
    Zhang, Peng
    Chen, Yuting
    Liu, Yuhang
    Li, Dun
    Tan, Lun
    Wang, Yina
    Wang, Dao Wen
    Yang, Xiaoyun
    Ma, Fei
    Li, Qiang
    MED, 2024, 5 (05): : 414 - 431
  • [23] HEART RATE RESPONSE TO REGADENOSON IN PATIENTS WITH ATRIAL FIBRILLATION
    Uzendu, A.
    Farag, A.
    Doppalapudi, H.
    Iskandrian, A. E.
    Hage, F. G.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2017, 65 (02) : 581 - 581
  • [24] Heart rate behavior in postablative patients with atrial fibrillation
    Ardashev, A.
    Shavarov, A.
    Zhelyakov, E.
    Dolgushina, E.
    EUROPEAN HEART JOURNAL, 2008, 29 : 168 - 168
  • [25] The heart rate response to regadenoson in patients with atrial fibrillation
    Anezi I. Uzendu
    Ami Iskandrian
    Fadi G. Hage
    Journal of Nuclear Cardiology, 2018, 25 : 1012 - 1016
  • [26] The heart rate response to regadenoson in patients with atrial fibrillation
    Uzendu, Anezi I.
    Iskandrian, Ami
    Hage, Fadi G.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (03) : 1012 - 1016
  • [27] Heart rate variability in patients with atrial fibrillation and hypertension
    Khan, Ahsan A.
    Junejo, Rehan T.
    Thomas, Graham N.
    Fisher, James P.
    Lip, Gregory Y. H.
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2021, 51 (01)
  • [28] Accuracy of wrist-worn heart rate monitors for chronotropic assessment in atrial fibrillation
    Al-Kaisey, A.
    Koshy, A.
    Ha, F. J.
    Sajeev, J.
    Toner, L.
    Spencer, R.
    Teh, A.
    Farouque, O.
    Lim, H. S.
    EUROPEAN HEART JOURNAL, 2019, 40 : 187 - 187
  • [29] Effect of skin tone and activity on the performance of wrist-worn optical beat-to-beat heart rate monitoring
    Puranen, Antti
    Halkola, Tuomas
    Kirkeby, Ole
    Vehkaoja, Antti
    2020 IEEE SENSORS, 2020,
  • [30] Development of heart inter-beat interval variability in preweanling rats: Effects of exposure to alcohol and hypoxia
    Kelly, SJ
    Richards, JE
    PHYSIOLOGY & BEHAVIOR, 1997, 61 (02) : 231 - 241