Monitoring of heart rate and inter-beat intervals with wrist plethysmography in patients with atrial fibrillation

被引:46
|
作者
Harju, Jarkko [1 ]
Tarniceriu, Adrian [2 ]
Parak, Jakub [3 ,4 ]
Vehkaoja, Antti [3 ,4 ]
Yli-Hankala, Arvi [1 ,5 ]
Korhonen, Ilkka [3 ,4 ]
机构
[1] Tampere Univ Hosp, Dept Anesthesia, Tampere, Finland
[2] PulseOn SA, Neuchatel, Switzerland
[3] Tampere Univ Technol, Tampere, Finland
[4] Pulseon Oy, Espoo, Finland
[5] Univ Tampere, Med Sch, Tampere, Finland
关键词
heart rate; pulse rate; photoplethysmography; atrial fibrillation; perioperative monitoring; RATE-VARIABILITY; ACCURACY; PREVALENCE; FAILURE; WORN;
D O I
10.1088/1361-6579/aac9a9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective: Atrial fibrillation (AF) causes marked risk for patients, while silent fibrillation may remain unnoticed if not suspected and screened. Development of comfortable yet accurate beat-to-beat heart rate (HR) monitoring with good AF detection sensitivity would facilitate screening and improve treatment. The purpose of this study was to evaluate whether a wrist-worn photoplethysmography (PPG) device can be used to monitor beat-to-beat HR accurately during post-operative treatment in patients suffering from AF and whether wrist-PPG can be used to distinguish AF from sinus rhythm (SR). Approach: Twenty-nine patients (14 with AF, 15 with SR, mean age 71.5 years) with multiple comorbidities were monitored during routine post-operative treatment. The monitoring included standard ECG, finger PPG monitoring and a wrist-worn PPG monitor with green and infrared light sources. The HR from PPG sensors was compared against ECG-derived HR. Main results: The wrist PPG technology had very good HR and beat detection accuracy when using green light. For the SR group, the mean absolute error (MAE) for HR was 1.50 bpm, and for the interbeat intervals (IBI), the MAE was 7.64 ms. For the AF group, the MAE for HR was 4.28 bpm and for IBI, the MAE was 14.67 ms. Accuracy for the infrared (IR) channel was worse. Finger PPG provided similar accuracy for HR and better accuracy for the IBI. AF detection sensitivity using green light was 99.0% and the specificity was 93.0%. Performance can be improved by discarding unreliable IBI periods. Significance: Results suggest that wrist PPG measurement allows accurate HR and beat-to-beat HR monitoring also in AF patients, and could be used for differentiating between SR and AF with very good sensitivity.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Management of Ventricular Heart Rate in Atrial Fibrillation Patients With Sepsis
    Proietti, Marco
    Romiti, Giulio Francesco
    CHEST, 2021, 159 (04) : 1315 - 1316
  • [42] Heart rate control with nebivolol in patients with tachysystolic atrial fibrillation
    Shubik, YV
    Medvedev, MM
    Kryatova, TV
    KARDIOLOGIYA, 2003, 43 (09) : 52 - 55
  • [43] Analysis of heart rate variability in patients with persistent atrial fibrillation
    Fushtey, I. M.
    Solovev, A. V.
    Sid, E. V.
    ZAPOROZHYE MEDICAL JOURNAL, 2014, (01) : 64 - 68
  • [44] Heart rate and adverse outcomes in patients with prevalent atrial fibrillation
    Moschovitis, Giorgio
    Johnson, Linda S. B.
    Blum, Steffen
    Aeschbacher, Stefanie
    De Perna, Maria Luisa
    Pagnamenta, Alberto
    Mayer Melchiorre, Patrizia Assunta
    Benz, Alexander P.
    Kobza, Richard
    Di Valentino, Marcello
    Zuern, Christine S.
    Auricchio, Angelo
    Conte, Giulio
    Rodondi, Nicolas
    Blum, Manuel R.
    Beer, Juerg H.
    Kuehne, Michael
    Osswald, Stefan
    Conen, David
    OPEN HEART, 2021, 8 (01):
  • [45] Heart Rate Variability Biofeedback in Patients With Paroxysmal Atrial Fibrillation
    Sadr-Ameli, Mohammad Ali
    Izadpanah, Parisa
    Sadr-Ameli, Sarlaf
    Maghooli, Keivan
    Madadi, Shalhahn
    IRANIAN HEART JOURNAL, 2021, 22 (02): : 68 - 76
  • [46] The Effect Of Dexmetomidine On Heart Rate Control In Patients With Atrial Fibrillation
    Salihi, W.
    Akinlolu, A.
    Ali, S. Z.
    Mansour, M. M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [47] RATE-CONTROL IN PATIENTS WITH ATRIAL FIBRILLATION AND HEART FAILURE
    DeLosSantos, Marci
    Jackson, Daniel
    Shami, Nadia
    CRITICAL CARE MEDICINE, 2009, 37 (12) : A106 - A106
  • [48] USING AN INNOVATIVE, NON-LINEAR GRAPH THEORETICAL METHOD IN DETECTING SUBLTE SEX DIFFERENCES IN INTER-BEAT INTERVALS OF THE HEART AMONG YOUNG HEALTHY ADULTS
    Sorensen, Lin
    Kvadsheim, Elisabet
    Thayer, Julian
    Williams, DeWayne
    Fasmer, Ole
    Osnes, Berge
    PSYCHOPHYSIOLOGY, 2024, 61 : S61 - S61
  • [49] CONTROL OF HEART RATE IN ATRIAL FIBRILLATION
    GENTZLER, RD
    PENNSYLVANIA MEDICINE, 1974, 77 (07) : 61 - 61
  • [50] Variation in heart rate range by 24-h Holter monitoring predicts heart failure in patients with atrial fibrillation
    Oikawa, Jun
    Fukaya, Hidehira
    Ishii, Shunsuke
    Nabeta, Takeru
    Nakamura, Hironori
    Ishizue, Naruya
    Kitasato, Lisa
    Kishihara, Jun
    Yamaoka-Tojo, Minako
    Niwano, Shinichi
    Ako, Junya
    ESC HEART FAILURE, 2022, 9 (05): : 3092 - 3100