The Effect of Stacking on the Accuracy of 3D-Printed Full-Arch Dental Models

被引:1
|
作者
Hartley, Olan [1 ]
Shanbhag, Tanvi [1 ]
Smith, Derek [2 ]
Grimm, Antonio [2 ]
Salameh, Ziad [3 ]
Tadakamadla, Santosh K. [4 ,5 ]
Alifui-Segbaya, Frank [1 ]
Ahmed, Khaled E. [1 ]
机构
[1] Griffith Univ, Sch Med & Dent, Ian OConnor Bldg G40, Gold Coast, Qld 4215, Australia
[2] Griffith Univ, Adv Design & Prototyping Technol Inst, Gold Coast, Qld 4215, Australia
[3] Lebanese Univ, Fac Dent Med, Beirut 1107, Lebanon
[4] La Trobe Univ, La Trobe Rural Hlth Sch, Dept Rural Clin Sci, Bendigo, Vic 3550, Australia
[5] La Trobe Univ, Violet Vines Marshman Ctr Rural Hlth Res, La Trobe Rural Hlth Sch, Bendigo, Vic 3550, Australia
关键词
3D printing; stacking; trueness; precision; accuracy; dental models; ORIENTATION; REPRODUCIBILITY; PACKING;
D O I
10.3390/polym14245465
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The objective of this study was to assess the effect of stacking on the dimensional and full-arch accuracy of 3D-printed models, utilising a standardised assessment methodology. A previously validated methodology involving a standard tessellation language image (STL) reference model, comprising seven spheres on a horseshoe base resembling a dental arch, was used. Six 3D-designed STL models were prepared, optimised, and stacked horizontally using 3D Sprint software. The stacking file was transferred to the NextDent 5100 printer to build the physical models. To assess accuracy, a coordinate measuring machine (CMM) measured the diameter of the spheres n=210, and twenty-one vectors extended between the centres of each of the seven spheres (n = 630). When compared to the reference model, significant differences were observed for dimensional (p = 0.006) and full-arch accuracy (p = 0.006) for all stacked models. Additionally, significant differences were observed between the stacked models for the dimensional accuracy between the posterior (p = 0.015), left posterior (p = 0.005) and anteroposterior (p = 0.002). The maximum contraction was observed in the fourth stacked model, which demonstrated the highest median deviation and least precision within the full-arch (MD = 666 mu m, IQR = 55 mu m), left posterior (MD = 136 mu m, IQR = 12 mu m), posterior (MD = 177 mu m, IQR = 14 mu m) and anteroposterior (MD = 179 mu m, IQR = 16 mu m) arch segments. In general, the anterior and left posterior arch segments recorded the highest contractions with a median deviation of 34 mu m and 29 mu m, and precision of 32 mu m and 22 mu m, respectively. Statistically significant differences were observed between the stacked models in terms of dimensional accuracy that were within clinically acceptable thresholds. The greatest contraction was noted in the fourth model, displaying the least full-arch accuracy compared to the other models. Stacked, additively manufactured, full arch models are a viable alternative for diagnostic, orthodontic, and single-unit prosthodontic applications. In contrast, caution should be exercised when utilising stacked models for full arch high accuracy prosthodontic applications. Further research is needed to assess the impact of additional variables including different printers and resins.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] The Effect of Sterilization on the Accuracy and Fit of 3D-Printed Surgical Guides
    Yazigi, Christine
    Chaar, M. Sad
    Busch, Reinhard
    Kern, Matthias
    MATERIALS, 2023, 16 (15)
  • [22] Effect of additive manufacturing process and storage condition on the dimensional accuracy and stability of 3D-printed dental casts
    Yousef, Hazem
    Harris, Bryan T.
    Elathamna, Eiad N.
    Morton, Dean
    Lin, Wei-Shao
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05): : 1041 - 1046
  • [23] Accuracy of 3D-Printed and Digitally Fabricated Polymeric Models for Dental Applications: A Systematic Review and Meta-Analysis
    Alshahrani, Abdullah
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2023, 13 (11) : 1061 - 1071
  • [24] Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions
    Akkal, Ozcan
    Korkmaz, Ismail Hakki
    Bayindir, Funda
    JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (04): : 179 - 188
  • [25] Trueness of full-arch dental models obtained by digital and conventional impression techniques: an in vivo study
    Yonca Onbasi
    Sabrin Abu-Hossin
    Maria Paulig
    Lara Berger
    Manfred Wichmann
    Ragai-Edward Matta
    Scientific Reports, 12 (1)
  • [26] In vivo full-arch accuracy of intraoral scanners: a narrative review
    Jennes, Marie-Elise
    Soetebeer, Maren
    Beuer, Florian
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2022, 25 (01) : 9 - 16
  • [27] Trueness of full-arch dental models obtained by digital and conventional impression techniques: an in vivo study
    Onbasi, Yonca
    Abu-Hossin, Sabrin
    Paulig, Maria
    Berger, Lara
    Wichmann, Manfred
    Matta, Ragai-Edward
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [28] Effect of a Novel 'Scan Body' on the In Vitro Scanning Accuracy of Full-Arch Implant Impressions
    Zhang, Tingting
    Yang, Bo
    Ge, Ruihan
    Zhang, Chaobiao
    Zhang, Hui
    Wang, Yan
    INTERNATIONAL DENTAL JOURNAL, 2024, 74 (04) : 847 - 854
  • [29] Accuracy of Digital and Conventional Full-Arch Impressions in Patients: An Update
    Schmidt, Alexander
    Klussmann, Leona
    Woestmann, Bernd
    Schlenz, Maximiliane Amelie
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (03)
  • [30] Accuracy of full-arch digital impressions: an in vitro and in vivo comparison
    Keul, Christine
    Gueth, Jan-Frederik
    CLINICAL ORAL INVESTIGATIONS, 2020, 24 (02) : 735 - 745