The Effect of Stacking on the Accuracy of 3D-Printed Full-Arch Dental Models

被引:1
|
作者
Hartley, Olan [1 ]
Shanbhag, Tanvi [1 ]
Smith, Derek [2 ]
Grimm, Antonio [2 ]
Salameh, Ziad [3 ]
Tadakamadla, Santosh K. [4 ,5 ]
Alifui-Segbaya, Frank [1 ]
Ahmed, Khaled E. [1 ]
机构
[1] Griffith Univ, Sch Med & Dent, Ian OConnor Bldg G40, Gold Coast, Qld 4215, Australia
[2] Griffith Univ, Adv Design & Prototyping Technol Inst, Gold Coast, Qld 4215, Australia
[3] Lebanese Univ, Fac Dent Med, Beirut 1107, Lebanon
[4] La Trobe Univ, La Trobe Rural Hlth Sch, Dept Rural Clin Sci, Bendigo, Vic 3550, Australia
[5] La Trobe Univ, Violet Vines Marshman Ctr Rural Hlth Res, La Trobe Rural Hlth Sch, Bendigo, Vic 3550, Australia
关键词
3D printing; stacking; trueness; precision; accuracy; dental models; ORIENTATION; REPRODUCIBILITY; PACKING;
D O I
10.3390/polym14245465
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The objective of this study was to assess the effect of stacking on the dimensional and full-arch accuracy of 3D-printed models, utilising a standardised assessment methodology. A previously validated methodology involving a standard tessellation language image (STL) reference model, comprising seven spheres on a horseshoe base resembling a dental arch, was used. Six 3D-designed STL models were prepared, optimised, and stacked horizontally using 3D Sprint software. The stacking file was transferred to the NextDent 5100 printer to build the physical models. To assess accuracy, a coordinate measuring machine (CMM) measured the diameter of the spheres n=210, and twenty-one vectors extended between the centres of each of the seven spheres (n = 630). When compared to the reference model, significant differences were observed for dimensional (p = 0.006) and full-arch accuracy (p = 0.006) for all stacked models. Additionally, significant differences were observed between the stacked models for the dimensional accuracy between the posterior (p = 0.015), left posterior (p = 0.005) and anteroposterior (p = 0.002). The maximum contraction was observed in the fourth stacked model, which demonstrated the highest median deviation and least precision within the full-arch (MD = 666 mu m, IQR = 55 mu m), left posterior (MD = 136 mu m, IQR = 12 mu m), posterior (MD = 177 mu m, IQR = 14 mu m) and anteroposterior (MD = 179 mu m, IQR = 16 mu m) arch segments. In general, the anterior and left posterior arch segments recorded the highest contractions with a median deviation of 34 mu m and 29 mu m, and precision of 32 mu m and 22 mu m, respectively. Statistically significant differences were observed between the stacked models in terms of dimensional accuracy that were within clinically acceptable thresholds. The greatest contraction was noted in the fourth model, displaying the least full-arch accuracy compared to the other models. Stacked, additively manufactured, full arch models are a viable alternative for diagnostic, orthodontic, and single-unit prosthodontic applications. In contrast, caution should be exercised when utilising stacked models for full arch high accuracy prosthodontic applications. Further research is needed to assess the impact of additional variables including different printers and resins.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Full-arch prostheses from translucent zirconia: Accuracy of fit
    Sachs, Caroline
    Groesser, Julian
    Stadelmann, Markus
    Schweiger, Josef
    Erdelt, Kurt
    Beuer, Florian
    DENTAL MATERIALS, 2014, 30 (08) : 817 - 823
  • [32] Accuracy of full-arch digital impressions: an in vitro and in vivo comparison
    Christine Keul
    Jan-Frederik Güth
    Clinical Oral Investigations, 2020, 24 : 735 - 745
  • [33] In vitro and in vivo accuracy of full-arch digital implant impressions
    Rutkunas, Vygandas
    Gedrimiene, Agne
    Akulauskas, Mykolas
    Fehmer, Vincent
    Sailer, Irena
    Jegelevicius, Darius
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (12) : 1444 - 1454
  • [34] 3D-Printed Linear Positioner with Micrometer Accuracy
    Kuo, Yin-Yen
    Cheng, Chiao-Hua
    Hung, Shao-Kang
    2016 THE 3RD INTERNATIONAL CONFERENCE ON MECHATRONICS AND MECHANICAL ENGINEERING (ICMME 2016), 2017, 95
  • [35] Accuracy assessment of 3D-printed tooth replicas
    Sokolowski, Armin Andreas
    Sokolowski, Alwin Alan
    Kammerhofer, Julian
    Madreiter-Sokolowski, Corina Theresia
    Payer, Michael
    Koller, Martin
    Jakse, Norbert
    Wegscheider, Walther Alfred
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2019, 22 (04) : 321 - 329
  • [36] Effect of print angulation on the accuracy and precision of 3D-printed orthodontic retainers
    Williams, Allison
    Bencharit, Sompop
    Yang, Il-Hyung
    Stilianoudakis, Spiro Christos
    Carrico, Caroline K.
    Tufekci, Eser
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2022, 161 (01) : 133 - 139
  • [37] 3D-Printed Maternal Pelvis Models
    Gomez, Isabella Sophia
    Benedetto-Anzai, Maria Teresa
    Yao, Nicole
    Sefah, Narvella
    Goldstein, Todd
    Neuwirth, Allison
    Trahan, Sean
    Anzai, Yuzuru
    REPRODUCTIVE SCIENCES, 2022, 29 (SUPPL 1) : 237 - 237
  • [38] On accuracy of personalized 3D-printed MRI-based models of brain arteries
    Kocinski, Marek
    Materka, Andrzej
    Elgalal, Marcin
    Majos, Agata
    2017 INTERNATIONAL CONFERENCE ON SYSTEMS, SIGNALS AND IMAGE PROCESSING (IWSSIP), 2017,
  • [39] Effect of print layer height on the assessment of 3D-printed models
    Loflin, Wyatt A.
    English, Jeryl D.
    Borders, Catharine
    Harris, Lacey M.
    Moon, Audrey
    Holland, J. Nathaniel
    Kasper, F. Kurtis
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2019, 156 (02) : 283 - 289
  • [40] Accuracy of maxillary full-arch digital impressions of tooth and implant models made by two intraoral scanners
    Siadat, Hakimeh
    Chitsaz, Foujan
    Zeighami, Somayeh
    Esmaeilzadeh, Alireza
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (02):