The Effect of Stacking on the Accuracy of 3D-Printed Full-Arch Dental Models

被引:1
|
作者
Hartley, Olan [1 ]
Shanbhag, Tanvi [1 ]
Smith, Derek [2 ]
Grimm, Antonio [2 ]
Salameh, Ziad [3 ]
Tadakamadla, Santosh K. [4 ,5 ]
Alifui-Segbaya, Frank [1 ]
Ahmed, Khaled E. [1 ]
机构
[1] Griffith Univ, Sch Med & Dent, Ian OConnor Bldg G40, Gold Coast, Qld 4215, Australia
[2] Griffith Univ, Adv Design & Prototyping Technol Inst, Gold Coast, Qld 4215, Australia
[3] Lebanese Univ, Fac Dent Med, Beirut 1107, Lebanon
[4] La Trobe Univ, La Trobe Rural Hlth Sch, Dept Rural Clin Sci, Bendigo, Vic 3550, Australia
[5] La Trobe Univ, Violet Vines Marshman Ctr Rural Hlth Res, La Trobe Rural Hlth Sch, Bendigo, Vic 3550, Australia
关键词
3D printing; stacking; trueness; precision; accuracy; dental models; ORIENTATION; REPRODUCIBILITY; PACKING;
D O I
10.3390/polym14245465
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The objective of this study was to assess the effect of stacking on the dimensional and full-arch accuracy of 3D-printed models, utilising a standardised assessment methodology. A previously validated methodology involving a standard tessellation language image (STL) reference model, comprising seven spheres on a horseshoe base resembling a dental arch, was used. Six 3D-designed STL models were prepared, optimised, and stacked horizontally using 3D Sprint software. The stacking file was transferred to the NextDent 5100 printer to build the physical models. To assess accuracy, a coordinate measuring machine (CMM) measured the diameter of the spheres n=210, and twenty-one vectors extended between the centres of each of the seven spheres (n = 630). When compared to the reference model, significant differences were observed for dimensional (p = 0.006) and full-arch accuracy (p = 0.006) for all stacked models. Additionally, significant differences were observed between the stacked models for the dimensional accuracy between the posterior (p = 0.015), left posterior (p = 0.005) and anteroposterior (p = 0.002). The maximum contraction was observed in the fourth stacked model, which demonstrated the highest median deviation and least precision within the full-arch (MD = 666 mu m, IQR = 55 mu m), left posterior (MD = 136 mu m, IQR = 12 mu m), posterior (MD = 177 mu m, IQR = 14 mu m) and anteroposterior (MD = 179 mu m, IQR = 16 mu m) arch segments. In general, the anterior and left posterior arch segments recorded the highest contractions with a median deviation of 34 mu m and 29 mu m, and precision of 32 mu m and 22 mu m, respectively. Statistically significant differences were observed between the stacked models in terms of dimensional accuracy that were within clinically acceptable thresholds. The greatest contraction was noted in the fourth model, displaying the least full-arch accuracy compared to the other models. Stacked, additively manufactured, full arch models are a viable alternative for diagnostic, orthodontic, and single-unit prosthodontic applications. In contrast, caution should be exercised when utilising stacked models for full arch high accuracy prosthodontic applications. Further research is needed to assess the impact of additional variables including different printers and resins.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Precision and Accuracy of a Digital Impression Scanner in Full-Arch Implant Rehabilitation
    Pesce, Paolo
    Pera, Francesco
    Setti, Paolo
    Menini, Maria
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (02) : 171 - 175
  • [42] A new method for the evaluation of the accuracy of full-arch digital impressions in vitro
    Jan-Frederik Güth
    Daniel Edelhoff
    Josef Schweiger
    Christine Keul
    Clinical Oral Investigations, 2016, 20 : 1487 - 1494
  • [43] A new method for the evaluation of the accuracy of full-arch digital impressions in vitro
    Gueth, Jan-Frederik
    Edelhoff, Daniel
    Schweiger, Josef
    Keul, Christine
    CLINICAL ORAL INVESTIGATIONS, 2016, 20 (07) : 1487 - 1494
  • [44] 'Invisible' orthodontics by polymeric 'clear' aligners molded on 3D-printed personalized dental models
    Yu, Xiaoye
    Li, Guanghui
    Zheng, Yikan
    Gao, Jingming
    Fu, Ye
    Wang, Qunsong
    Huang, Lei
    Pan, Xiaogang
    Ding, Jiandong
    REGENERATIVE BIOMATERIALS, 2022, 9 (01)
  • [45] Accuracy of Dental Restorations Fabricated Using Milling vs 3D-Printed Molds: A Pilot Study
    Ahlholm, Pekka
    Sipila, Kirsi
    Tarvonen, Pirkko-Liisa
    Silvast, Tuomo
    Lappalainen, Reijo
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 : S79 - S88
  • [46] 'Invisible' orthodontics by polymeric 'clear' aligners molded on 3D-printed personalized dental models
    Yu, Xiaoye
    Li, Guanghui
    Zheng, Yikan
    Gao, Jingming
    Fu, Ye
    Wang, Qunsong
    Huang, Lei
    Pan, Xiaogang
    Ding, Jiandong
    Regenerative Biomaterials, 2022, 9
  • [47] Development of New Surgical Training for Full Endoscopic Surgery Using 3D-Printed Models
    Ogawa, Takahiro
    Morimoto, Masatoshi
    Fujimoto, Shutaro
    Tominaga, Masaru
    Omichi, Yasuyuki
    Sugiura, Kosuke
    Tezuka, Fumitake
    Yamashita, Kazuta
    Sairyo, Koichi
    SPINE SURGERY AND RELATED RESEARCH, 2024, 8 (06): : 591 - 599
  • [48] Evaluation of the dimensional stability of 3D-printed dental casts
    Vincze, Zsofia Eva
    Kovacs, Zoltan Imre
    Vass, Andrea Fanni
    Borbely, Judit
    Marton, Krisztina
    JOURNAL OF DENTISTRY, 2024, 151
  • [49] Biocompatibility of 3D-Printed Dental Resins: A Systematic Review
    Prakash, Jayant
    Shenoy, Mahesh
    Alhasmi, Abdulmajeed
    Saleh, Azzam A. Al
    Shivakumar, G. C.
    Shivakumar, Sahana
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [50] Application of 3D-printed colored 3D-models for the fabrication of full ceramic restorations: A technical report
    Schweiger, Josef
    Gueth, Jan-Frederik
    Edelhoff, Daniel
    Seidel, Kathrin
    Graf, Tobias
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (01) : 235 - 243