Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions

被引:1
|
作者
Akkal, Ozcan [1 ]
Korkmaz, Ismail Hakki [2 ]
Bayindir, Funda [1 ]
机构
[1] Ataturk Univ, Fac Dent, Dept Prosthodont, Erzurum, Turkiye
[2] Erzurum Tech Univ, Fac Engn & Architecture, Dept Mech Engn, TR-25050 Erzurum, Turkiye
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2023年 / 15卷 / 04期
关键词
Accuracy; Angled implant; Digital implant impression; Full arch; Intraoral scanner; AMBIENT LIGHT; PRECISION; TRUENESS;
D O I
10.4047/jap.2023.15.4.179
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This in vitro study aimed to evaluate the performance of digital intraoral scanners in a completely edentulous patient with angled and parallel implants. MATERIALS AND METHODS. A total of 6 implants were placed at angulations of 0 degrees, 5 degrees, 0 degrees, 0 degrees, 15 degrees, and 0 degrees in regions #36, #34, #32, #42, #44, and #46, respectively, in a completely edentulous mandibular polyurethane model. Then, the study model created by connecting a scan body on the implants was scanned using a model scanner, and a 3D reference model was obtained. Three different intraoral scanners were used for digital impressions (PS group, TR group, and CS group, n = 10 in each group). The distances and angles between the scan bodies in these measurement groups were measured. RESULTS. While the Primescan (PS) impression group had the highest accuracy with 38 mu m, the values of 104 mu m and 171 mu m were obtained with Trios 4 IOSs (TR) and Carestream 3600 (CS), respectively ( P =.001). The CS scanner constituted the impression group with the highest deviation in terms of accuracy. In terms of dimensional differences in the angle parameter, a statistically significant difference was revealed among the mean deviation angle values according to the scanners ( P <.001). While the lowest angular deviation was obtained with the PS impression group with 0.185 degrees, the values of 0.499 degrees and 1.250 degrees were obtained with TR and CS, respectively. No statistically significant difference was detected among the impression groups in terms of precision values ( P >.05). CONCLUSION. A statistically significant difference was found among the three digital impression groups upon comparing the impression accuracy. Implant angulation affected the impression accuracy of the digital impression groups. The most accurate impressions in terms of both distance and angle deviation were obtained with the PS impression group. [J Adv Prosthodont 2023;15:179-88]
引用
收藏
页码:179 / 188
页数:10
相关论文
共 50 条
  • [1] Accuracy of maxillary full-arch digital impressions of tooth and implant models made by two intraoral scanners
    Siadat, Hakimeh
    Chitsaz, Foujan
    Zeighami, Somayeh
    Esmaeilzadeh, Alireza
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (02):
  • [2] Accuracy of full-arch digital implant impressions taken using intraoral scanners and related variables: A systematic review
    Zhang, Yi-Jie
    Shi, Jun-Yu
    Qian, Shu-Jiao
    Qiao, Shi-Chong
    Lai, Hong-Chang
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2021, 14 (02) : 157 - 179
  • [3] In vitro and in vivo accuracy of full-arch digital implant impressions
    Rutkunas, Vygandas
    Gedrimiene, Agne
    Akulauskas, Mykolas
    Fehmer, Vincent
    Sailer, Irena
    Jegelevicius, Darius
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (12) : 1444 - 1454
  • [4] Accuracy of full-arch scans using intraoral scanners
    Patzelt, Sebastian B. M.
    Emmanouilidi, Archontia
    Stampf, Susanne
    Strub, Joerg R.
    Att, Wael
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (06) : 1687 - 1694
  • [5] Accuracy of full-arch scans using intraoral scanners
    Sebastian B. M. Patzelt
    Archontia Emmanouilidi
    Susanne Stampf
    Joerg R. Strub
    Wael Att
    Clinical Oral Investigations, 2014, 18 : 1687 - 1694
  • [6] Accuracy, reliability, and efficiency of intraoral scanners for full-arch impressions: a systematic review of the clinical evidence
    Goracci, Cecilia
    Franchi, Lorenzo
    Vichi, Alessandro
    Ferrari, Marco
    EUROPEAN JOURNAL OF ORTHODONTICS, 2016, 38 (04) : 422 - 428
  • [7] Accuracy of full-arch digital impressions: an in vitro and in vivo comparison
    Keul, Christine
    Gueth, Jan-Frederik
    CLINICAL ORAL INVESTIGATIONS, 2020, 24 (02) : 735 - 745
  • [8] Accuracy of full-arch digital impressions: an in vitro and in vivo comparison
    Christine Keul
    Jan-Frederik Güth
    Clinical Oral Investigations, 2020, 24 : 735 - 745
  • [9] Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study
    Di Fiore, Adolfo
    Graiff, Lorenzo
    Savio, Gianpaolo
    Granata, Stefano
    Basilicata, Michele
    Bollero, Patrizio
    Meneghello, Roberto
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (08)
  • [10] In vivo full-arch accuracy of intraoral scanners: a narrative review
    Jennes, Marie-Elise
    Soetebeer, Maren
    Beuer, Florian
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2022, 25 (01) : 9 - 16