Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions

被引:1
|
作者
Akkal, Ozcan [1 ]
Korkmaz, Ismail Hakki [2 ]
Bayindir, Funda [1 ]
机构
[1] Ataturk Univ, Fac Dent, Dept Prosthodont, Erzurum, Turkiye
[2] Erzurum Tech Univ, Fac Engn & Architecture, Dept Mech Engn, TR-25050 Erzurum, Turkiye
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2023年 / 15卷 / 04期
关键词
Accuracy; Angled implant; Digital implant impression; Full arch; Intraoral scanner; AMBIENT LIGHT; PRECISION; TRUENESS;
D O I
10.4047/jap.2023.15.4.179
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This in vitro study aimed to evaluate the performance of digital intraoral scanners in a completely edentulous patient with angled and parallel implants. MATERIALS AND METHODS. A total of 6 implants were placed at angulations of 0 degrees, 5 degrees, 0 degrees, 0 degrees, 15 degrees, and 0 degrees in regions #36, #34, #32, #42, #44, and #46, respectively, in a completely edentulous mandibular polyurethane model. Then, the study model created by connecting a scan body on the implants was scanned using a model scanner, and a 3D reference model was obtained. Three different intraoral scanners were used for digital impressions (PS group, TR group, and CS group, n = 10 in each group). The distances and angles between the scan bodies in these measurement groups were measured. RESULTS. While the Primescan (PS) impression group had the highest accuracy with 38 mu m, the values of 104 mu m and 171 mu m were obtained with Trios 4 IOSs (TR) and Carestream 3600 (CS), respectively ( P =.001). The CS scanner constituted the impression group with the highest deviation in terms of accuracy. In terms of dimensional differences in the angle parameter, a statistically significant difference was revealed among the mean deviation angle values according to the scanners ( P <.001). While the lowest angular deviation was obtained with the PS impression group with 0.185 degrees, the values of 0.499 degrees and 1.250 degrees were obtained with TR and CS, respectively. No statistically significant difference was detected among the impression groups in terms of precision values ( P >.05). CONCLUSION. A statistically significant difference was found among the three digital impression groups upon comparing the impression accuracy. Implant angulation affected the impression accuracy of the digital impression groups. The most accurate impressions in terms of both distance and angle deviation were obtained with the PS impression group. [J Adv Prosthodont 2023;15:179-88]
引用
收藏
页码:179 / 188
页数:10
相关论文
共 50 条
  • [21] Accuracy of digital implant impressions with intraoral scanners. A systematic review
    Rutkunas, Vygandas
    Geciauskaite, Agne
    Jegelevicius, Darius
    Vaitiekunas, Mantas
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2017, 10 : 101 - 120
  • [22] The Comparison of Accuracy of Post Space Digital Impressions Made by Three Different Intraoral Scanners: An In Vitro Study
    Meshni, Abdullah A.
    Jain, Saurabh
    Osaysi, Hanan Nasser Marie
    Hezam, Khadijah Nasser
    Adlan, Samar Samir Gomaan
    DIAGNOSTICS, 2024, 14 (24)
  • [23] Effects of the intraoral scanner and implant library on the trueness of digital impressions in the full-arch implant scan: A comparative in vitro study
    Hauschild, Uli
    Lerner, Henriette
    Weigl, Paul
    Porra, Tommaso
    Admakin, Oleg
    Mangano, Francesco Guido
    JOURNAL OF DENTISTRY, 2024, 150
  • [24] Accuracy of Digital and Conventional Full-Arch Impressions in Patients: An Update
    Schmidt, Alexander
    Klussmann, Leona
    Woestmann, Bernd
    Schlenz, Maximiliane Amelie
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (03)
  • [25] Accuracy and efficiency of full-arch digitalization and 3D printing: A comparison between desktop model scanners, an intraoral scanner, a CBCT model scan, and stereolithographic 3D printing
    Wesemann, Christian
    Muallah, Jonas
    Mah, James
    Bumann, Axel
    QUINTESSENCE INTERNATIONAL, 2017, 48 (01): : 41 - 50
  • [26] Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study
    Drancourt, Noemie
    Auduc, Chantal
    Mouget, Aymeric
    Mouminoux, Jean
    Auroy, Pascal
    Veyrune, Jean-Luc
    El Osta, Nada
    Nicolas, Emmanuel
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (05):
  • [27] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Mangano, Francesco Guido
    Admakin, Oleg
    Bonacina, Matteo
    Lerner, Henriette
    Rutkunas, Vygandas
    Mangano, Carlo
    BMC ORAL HEALTH, 2020, 20 (01)
  • [28] Comparison of Intraoral Scanning Modes in Three Distinct Full-Arch Digital Implant Impression Scenarios: An In Vitro Study
    Sezer, Taygun
    Yilmaz, Erkan
    Esim, Emir
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (06) : e217 - e222
  • [29] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Francesco Guido Mangano
    Oleg Admakin
    Matteo Bonacina
    Henriette Lerner
    Vygandas Rutkunas
    Carlo Mangano
    BMC Oral Health, 20
  • [30] Trueness of Extraoral Digital Impressions for Full-Arch Implant Impressions-In Vitro Study
    Sampaio-Fernandes, Manuel Antonio
    Pinto, Ricardo
    Almeida, Paulo Rocha
    Sampaio-Fernandes, Maria Margarida
    Marques, Duarte
    Figueiral, Maria Helena
    MATERIALS, 2024, 17 (12)