Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions

被引:1
|
作者
Akkal, Ozcan [1 ]
Korkmaz, Ismail Hakki [2 ]
Bayindir, Funda [1 ]
机构
[1] Ataturk Univ, Fac Dent, Dept Prosthodont, Erzurum, Turkiye
[2] Erzurum Tech Univ, Fac Engn & Architecture, Dept Mech Engn, TR-25050 Erzurum, Turkiye
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2023年 / 15卷 / 04期
关键词
Accuracy; Angled implant; Digital implant impression; Full arch; Intraoral scanner; AMBIENT LIGHT; PRECISION; TRUENESS;
D O I
10.4047/jap.2023.15.4.179
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This in vitro study aimed to evaluate the performance of digital intraoral scanners in a completely edentulous patient with angled and parallel implants. MATERIALS AND METHODS. A total of 6 implants were placed at angulations of 0 degrees, 5 degrees, 0 degrees, 0 degrees, 15 degrees, and 0 degrees in regions #36, #34, #32, #42, #44, and #46, respectively, in a completely edentulous mandibular polyurethane model. Then, the study model created by connecting a scan body on the implants was scanned using a model scanner, and a 3D reference model was obtained. Three different intraoral scanners were used for digital impressions (PS group, TR group, and CS group, n = 10 in each group). The distances and angles between the scan bodies in these measurement groups were measured. RESULTS. While the Primescan (PS) impression group had the highest accuracy with 38 mu m, the values of 104 mu m and 171 mu m were obtained with Trios 4 IOSs (TR) and Carestream 3600 (CS), respectively ( P =.001). The CS scanner constituted the impression group with the highest deviation in terms of accuracy. In terms of dimensional differences in the angle parameter, a statistically significant difference was revealed among the mean deviation angle values according to the scanners ( P <.001). While the lowest angular deviation was obtained with the PS impression group with 0.185 degrees, the values of 0.499 degrees and 1.250 degrees were obtained with TR and CS, respectively. No statistically significant difference was detected among the impression groups in terms of precision values ( P >.05). CONCLUSION. A statistically significant difference was found among the three digital impression groups upon comparing the impression accuracy. Implant angulation affected the impression accuracy of the digital impression groups. The most accurate impressions in terms of both distance and angle deviation were obtained with the PS impression group. [J Adv Prosthodont 2023;15:179-88]
引用
收藏
页码:179 / 188
页数:10
相关论文
共 50 条
  • [41] Digital vs. conventional full-arch implant impressions: a comparative study
    Amin, Sarah
    Weber, Hans Peter
    Finkelman, Matthew
    El Rafie, Khaled
    Kudara, Yukio
    Papaspyridakos, Panos
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (11) : 1360 - 1367
  • [42] Evaluating the impact of scan body angulation and geometric attachments on the accuracy of complete-arch digital implant impressions: A comparison of two intraoral scanners
    Farah, Ra'fat I.
    Alresheedi, Bandar
    Alazmi, Saad
    Al-Haj Ali, Sanaa N.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025, 34 (02): : 174 - 181
  • [43] Effect of a Novel 'Scan Body' on the In Vitro Scanning Accuracy of Full-Arch Implant Impressions
    Zhang, Tingting
    Yang, Bo
    Ge, Ruihan
    Zhang, Chaobiao
    Zhang, Hui
    Wang, Yan
    INTERNATIONAL DENTAL JOURNAL, 2024, 74 (04) : 847 - 854
  • [44] Precision and Accuracy of a Digital Impression Scanner in Full-Arch Implant Rehabilitation
    Pesce, Paolo
    Pera, Francesco
    Setti, Paolo
    Menini, Maria
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (02) : 171 - 175
  • [45] Influence of Scanning-Aid Materials on the Accuracy and Time Efficiency of Intraoral Scanners for Full-Arch Digital Scanning: An In Vitro Study
    Oh, Hyun-Su
    Lim, Young-Jun
    Kim, Bongju
    Kim, Myung-Joo
    Kwon, Ho-Beom
    Baek, Yeon-Wha
    MATERIALS, 2021, 14 (09)
  • [46] Digital versus conventional full-arch impressions in linear and 3D accuracy: a systematic review and meta-analysis of in vivo studies
    Lin Kong
    Yabing Li
    Zhijian Liu
    Clinical Oral Investigations, 2022, 26 : 5625 - 5642
  • [47] Digital versus conventional full-arch impressions in linear and 3D accuracy: a systematic review and meta-analysis of in vivo studies
    Kong, Lin
    Li, Yabing
    Liu, Zhijian
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (09) : 5625 - 5642
  • [48] Calibrated intraoral scan protocol (CISP) for full-arch implant impressions: An in vitro comparison to conventional impression, intraoral scan, and intraoral scan with scan-aid
    Li, Junying
    Chen, Zhaozhao
    Nava, Paolo
    Yang, Shengtao
    Calatrava, Javier
    Wang, Hom-Lay
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (05) : 879 - 888
  • [49] Full arch accuracy of intraoral scanners with different acquisition technologies: An in vitro study
    Baresel, Ingo
    Baresel, Jens
    JOURNAL OF DENTISTRY, 2025, 156
  • [50] Evidence for use of intraoral scanners under clinical conditions for obtaining full-arch digital impressions is insufficientQuestion: Have the current scanning systems for complete arch digital impressions been tested under clinical conditions for their reliability, accuracy and reproducibility?
    Hadil Khraishi
    Brett Duane
    Evidence-Based Dentistry, 2017, 18 (1) : 24 - 25