Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions

被引:1
|
作者
Akkal, Ozcan [1 ]
Korkmaz, Ismail Hakki [2 ]
Bayindir, Funda [1 ]
机构
[1] Ataturk Univ, Fac Dent, Dept Prosthodont, Erzurum, Turkiye
[2] Erzurum Tech Univ, Fac Engn & Architecture, Dept Mech Engn, TR-25050 Erzurum, Turkiye
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2023年 / 15卷 / 04期
关键词
Accuracy; Angled implant; Digital implant impression; Full arch; Intraoral scanner; AMBIENT LIGHT; PRECISION; TRUENESS;
D O I
10.4047/jap.2023.15.4.179
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This in vitro study aimed to evaluate the performance of digital intraoral scanners in a completely edentulous patient with angled and parallel implants. MATERIALS AND METHODS. A total of 6 implants were placed at angulations of 0 degrees, 5 degrees, 0 degrees, 0 degrees, 15 degrees, and 0 degrees in regions #36, #34, #32, #42, #44, and #46, respectively, in a completely edentulous mandibular polyurethane model. Then, the study model created by connecting a scan body on the implants was scanned using a model scanner, and a 3D reference model was obtained. Three different intraoral scanners were used for digital impressions (PS group, TR group, and CS group, n = 10 in each group). The distances and angles between the scan bodies in these measurement groups were measured. RESULTS. While the Primescan (PS) impression group had the highest accuracy with 38 mu m, the values of 104 mu m and 171 mu m were obtained with Trios 4 IOSs (TR) and Carestream 3600 (CS), respectively ( P =.001). The CS scanner constituted the impression group with the highest deviation in terms of accuracy. In terms of dimensional differences in the angle parameter, a statistically significant difference was revealed among the mean deviation angle values according to the scanners ( P <.001). While the lowest angular deviation was obtained with the PS impression group with 0.185 degrees, the values of 0.499 degrees and 1.250 degrees were obtained with TR and CS, respectively. No statistically significant difference was detected among the impression groups in terms of precision values ( P >.05). CONCLUSION. A statistically significant difference was found among the three digital impression groups upon comparing the impression accuracy. Implant angulation affected the impression accuracy of the digital impression groups. The most accurate impressions in terms of both distance and angle deviation were obtained with the PS impression group. [J Adv Prosthodont 2023;15:179-88]
引用
收藏
页码:179 / 188
页数:10
相关论文
共 50 条
  • [31] Case Report: Accuracy analysis of a new scanning body for intraoral digital impressions in full-arch edentulous patients
    Ma, Hongyang
    Cao, Jia
    Tang, Zhihui
    Wu, Yuwei
    FRONTIERS IN ORAL HEALTH, 2025, 6
  • [32] Three-Dimensional Accuracy of Digital Implant Impressions: Effects of Different Scanners and Implant Level
    Chew, Amelia A.
    Esguerra, Roxanna J.
    Teoh, K. H.
    Wong, K. M.
    Ng, Simon D.
    Tan, Keson B.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 70 - 80
  • [33] Effect of different arch widths on the accuracy of three intraoral scanners
    Kaewbuasa, Narin
    Ongthiemsak, Chakree
    JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (04): : 205 - 215
  • [34] A new method for the evaluation of the accuracy of full-arch digital impressions in vitro
    Jan-Frederik Güth
    Daniel Edelhoff
    Josef Schweiger
    Christine Keul
    Clinical Oral Investigations, 2016, 20 : 1487 - 1494
  • [35] Solid index versus intraoral scanners in the full-arch implant impression: in vitro trueness evaluation
    Mangano, Francesco Guido
    Bonacina, Matteo
    Mandelli, Federico
    Marchiori, Fabio
    BMC RESEARCH NOTES, 2020, 13 (01)
  • [36] A new method for the evaluation of the accuracy of full-arch digital impressions in vitro
    Gueth, Jan-Frederik
    Edelhoff, Daniel
    Schweiger, Josef
    Keul, Christine
    CLINICAL ORAL INVESTIGATIONS, 2016, 20 (07) : 1487 - 1494
  • [37] Digital Intraoral Scanners and Alginate Impressions in Reproducing Full Dental Arches: A Comparative 3D Assessment
    Lee, Kyungmin Clara
    Park, Seong-Joon
    APPLIED SCIENCES-BASEL, 2020, 10 (21): : 1 - 7
  • [38] Accuracy of a novel stereophotogrammetry system for full-arch digital implant impressions: An in vitro study and clinical case
    Ye, Yuping
    Gu, Feifei
    Liang, Jixin
    Han, Juncheng
    Tang, Zhenzhong
    Song, Zhan
    MEASUREMENT, 2024, 244
  • [39] Solid index versus intraoral scanners in the full-arch implant impression: in vitro trueness evaluation
    Francesco Guido Mangano
    Matteo Bonacina
    Federico Mandelli
    Fabio Marchiori
    BMC Research Notes, 13
  • [40] Influence of scan pattern on full-arch scans with three digital scanners
    Wagner, M. W.
    Vukovic, M. A.
    Grimm, W. D.
    JOURNAL OF OSSEOINTEGRATION, 2024, 16 (02) : 81 - 86