The Effect of Stacking on the Accuracy of 3D-Printed Full-Arch Dental Models

被引:1
|
作者
Hartley, Olan [1 ]
Shanbhag, Tanvi [1 ]
Smith, Derek [2 ]
Grimm, Antonio [2 ]
Salameh, Ziad [3 ]
Tadakamadla, Santosh K. [4 ,5 ]
Alifui-Segbaya, Frank [1 ]
Ahmed, Khaled E. [1 ]
机构
[1] Griffith Univ, Sch Med & Dent, Ian OConnor Bldg G40, Gold Coast, Qld 4215, Australia
[2] Griffith Univ, Adv Design & Prototyping Technol Inst, Gold Coast, Qld 4215, Australia
[3] Lebanese Univ, Fac Dent Med, Beirut 1107, Lebanon
[4] La Trobe Univ, La Trobe Rural Hlth Sch, Dept Rural Clin Sci, Bendigo, Vic 3550, Australia
[5] La Trobe Univ, Violet Vines Marshman Ctr Rural Hlth Res, La Trobe Rural Hlth Sch, Bendigo, Vic 3550, Australia
关键词
3D printing; stacking; trueness; precision; accuracy; dental models; ORIENTATION; REPRODUCIBILITY; PACKING;
D O I
10.3390/polym14245465
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The objective of this study was to assess the effect of stacking on the dimensional and full-arch accuracy of 3D-printed models, utilising a standardised assessment methodology. A previously validated methodology involving a standard tessellation language image (STL) reference model, comprising seven spheres on a horseshoe base resembling a dental arch, was used. Six 3D-designed STL models were prepared, optimised, and stacked horizontally using 3D Sprint software. The stacking file was transferred to the NextDent 5100 printer to build the physical models. To assess accuracy, a coordinate measuring machine (CMM) measured the diameter of the spheres n=210, and twenty-one vectors extended between the centres of each of the seven spheres (n = 630). When compared to the reference model, significant differences were observed for dimensional (p = 0.006) and full-arch accuracy (p = 0.006) for all stacked models. Additionally, significant differences were observed between the stacked models for the dimensional accuracy between the posterior (p = 0.015), left posterior (p = 0.005) and anteroposterior (p = 0.002). The maximum contraction was observed in the fourth stacked model, which demonstrated the highest median deviation and least precision within the full-arch (MD = 666 mu m, IQR = 55 mu m), left posterior (MD = 136 mu m, IQR = 12 mu m), posterior (MD = 177 mu m, IQR = 14 mu m) and anteroposterior (MD = 179 mu m, IQR = 16 mu m) arch segments. In general, the anterior and left posterior arch segments recorded the highest contractions with a median deviation of 34 mu m and 29 mu m, and precision of 32 mu m and 22 mu m, respectively. Statistically significant differences were observed between the stacked models in terms of dimensional accuracy that were within clinically acceptable thresholds. The greatest contraction was noted in the fourth model, displaying the least full-arch accuracy compared to the other models. Stacked, additively manufactured, full arch models are a viable alternative for diagnostic, orthodontic, and single-unit prosthodontic applications. In contrast, caution should be exercised when utilising stacked models for full arch high accuracy prosthodontic applications. Further research is needed to assess the impact of additional variables including different printers and resins.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Accuracy of 3-Dimensionally Printed Full-Arch Dental Models: A Systematic Review
    Etemad-Shahidi, Yasaman
    Qallandar, Omel Baneen
    Evenden, Jessica
    Alifui-Segbaya, Frank
    Ahmed, Khaled Elsayed
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (10) : 1 - 18
  • [2] Effect of internal structures on the accuracy of 3D printed full-arch dentition preparation models in different printing systems
    Ma, Teng
    Peng, Tiwu
    Lin, Yang
    Zhang, Mindi
    Ren, Guanghui
    JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (03): : 145 - 154
  • [3] Effect of different storage conditions on dimensional accuracy of 3D-printed dental models
    Alshaibani, Raghdah M.
    Fan, Yuwei
    Giordano II, Russell
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [4] Survival and Success of 3D-Printed Versus Milled Immediate Provisional Full-Arch Restorations: A Retrospective Analysis
    Sobczak, Barbara
    Majewski, Piotr
    Egorenkov, Evgenii
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2025, 27 (01)
  • [5] Impact of Aging on the Accuracy of 3D-Printed Dental Models: An In Vitro Investigation
    Joda, Tim
    Matthisson, Lea
    Zitzmann, Nicola U.
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (05)
  • [6] The Accuracy of 3D-Printed Fixed Dental Restorations
    Alammar, Amirah
    Att, Wael
    Beuer, Florian
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024,
  • [7] Investigations on the accuracy of 3D-printed drill guides for dental implantology
    Neumeister, A.
    Schulz, L.
    Glodecki, C.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2017, 20 (01) : 35 - 51
  • [8] Dimensional accuracy and surface characteristics of 3D-printed dental casts
    Park, Ji-Man
    Jeon, Jin
    Koak, Jai-Young
    Kim, Seong-Kyun
    Heo, Seong-Joo
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (03): : 427 - 437
  • [9] Assessing the Impact of Resin Type, Post-Processing Technique, and Arch Location on the Trueness and Precision of 3D-Printed Full-Arch Implant Surgical Guides
    Vara, Rhea
    Lin, William
    Low, Jhi Kwan
    Smith, Derek
    Grimm, Antonio
    Calvert, Gareth
    Tadakamadla, Santosh Kumar
    Alifui-Segbaya, Frank
    Ahmed, Khaled E.
    APPLIED SCIENCES-BASEL, 2023, 13 (04):
  • [10] Modular Digital and 3D-Printed Dental Models with Applicability in Dental Education
    Petre, Alexandru Eugen
    Pantea, Mihaela
    Drafta, Sergiu
    Imre, Marina
    Tancu, Ana Maria Cristina
    Liciu, Eduard M.
    Didilescu, Andreea Cristiana
    Pituru, Silviu Mirel
    MEDICINA-LITHUANIA, 2023, 59 (01):