Effect of different storage conditions on dimensional accuracy of 3D-printed dental models

被引:2
|
作者
Alshaibani, Raghdah M. [1 ,2 ]
Fan, Yuwei [1 ]
Giordano II, Russell [1 ]
机构
[1] Boston Univ, Henry M Goldman Sch Dent Med, Dept Restorat Sci & Biomat, 72 E Concord St,R-520, Boston, MA 02118 USA
[2] Princess Nourah Bint Abdul Rahman Univ, Dept Clin Dent Sci, Riyadh, Saudi Arabia
关键词
biomedical and dental materials; dental models; dental prosthesis; dimensional measurement accuracy; prosthodontics; temperature; three-dimensional printing; CASTS;
D O I
10.1111/jopr.13834
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeThe objective was to determine the accuracy of 3D-printed dental models subjected to different storage conditions using six different material and printer combinations.Materials and MethodsThree completely dentate models were designed using dental CAD software (3Shape Dental System). A horseshoe-shaped solid base with a posterior horizontal bar was used. The models were printed in a horizontal direction against the building platform without support. The models were printed using six printers with the corresponding recommended resin material: Carbon M2 (DPR10), HeyGears A2D4K (Model HP UV2.0), Stratasys J5 (MED610), Stratasys Origin One (DM200), Envision One (E-Model LightDLP), and Asiga Pro4K (VeriModel) with a standard layer thickness of 50 mu m. All printed models underwent scanning using a laboratory scanner (Sirona inEOS X5) after printing. Subsequently, the models were randomly assigned into three groups of storage conditions, LT: cold environment (4 +/- 1 degrees C), HT: hot and dry environment (50 +/- 2 degrees C), and RT: room temperature (25 +/- 2 degrees C) serving as the control. Each group was kept under the designated condition and was scanned at 1, 2, 3, 4, and 8 weeks. The total number of models (N) was 72, with 6 printers producing 12 models per printer for 3 storage conditions, resulting in 4 models for each storage condition and each printer. The generated STL files were imported into a 3D inspection software for comparison with the original STL files. In-tolerance percentage, the deviation RMS, trueness, and precision were obtained and analyzed with least square mean linear regression using JMP Pro 15 to identify the significant effects (alpha = 0.05).ResultsThe in-tolerance percentage as-printed was significantly different among different printers. Significant dimension deviations were observed after the first week of storage at HT and with subsequent weeks of storage. RT and LT did not show significant dimensional changes. Models printed with Carbon M2 showed the highest in-tolerance percentages compared to the other printers.ConclusionsThe model deviations were affected by storage conditions and the printer used, with high-temperature storage showed least stability compared to low and room temperatures. No significant difference was observed between low and room temperature storage conditions. The Carbon M2 printer showed the highest accuracy among all printers tested. The region had a significant effect on the deviation measured, with the abutment body showing the least deviation. Among the 3D printers evaluated, A2D4K by HeyGears and Carbon M2 printers demonstrated the highest accuracy in terms of both precision and trueness.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Effect of additive manufacturing process and storage condition on the dimensional accuracy and stability of 3D-printed dental casts
    Yousef, Hazem
    Harris, Bryan T.
    Elathamna, Eiad N.
    Morton, Dean
    Lin, Wei-Shao
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05): : 1041 - 1046
  • [2] The Effect of Stacking on the Accuracy of 3D-Printed Full-Arch Dental Models
    Hartley, Olan
    Shanbhag, Tanvi
    Smith, Derek
    Grimm, Antonio
    Salameh, Ziad
    Tadakamadla, Santosh K.
    Alifui-Segbaya, Frank
    Ahmed, Khaled E.
    POLYMERS, 2022, 14 (24)
  • [3] Dimensional accuracy and surface characteristics of 3D-printed dental casts
    Park, Ji-Man
    Jeon, Jin
    Koak, Jai-Young
    Kim, Seong-Kyun
    Heo, Seong-Joo
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (03): : 427 - 437
  • [4] Impact of Aging on the Accuracy of 3D-Printed Dental Models: An In Vitro Investigation
    Joda, Tim
    Matthisson, Lea
    Zitzmann, Nicola U.
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (05)
  • [5] The Accuracy of 3D-Printed Fixed Dental Restorations
    Alammar, Amirah
    Att, Wael
    Beuer, Florian
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024,
  • [6] An in vitro comparison of the dimensional stability of four 3D-printed models under various storage conditions
    Knode, Vanessa
    Ludwig, Bjoern
    Hamadeh, Sinan
    Pandis, Nikolaos
    Fleming, Padhraig S.
    ANGLE ORTHODONTIST, 2024, 94 (03) : 346 - 352
  • [7] Evaluation of the dimensional stability of 3D-printed dental casts
    Vincze, Zsofia Eva
    Kovacs, Zoltan Imre
    Vass, Andrea Fanni
    Borbely, Judit
    Marton, Krisztina
    JOURNAL OF DENTISTRY, 2024, 151
  • [8] Investigations on the accuracy of 3D-printed drill guides for dental implantology
    Neumeister, A.
    Schulz, L.
    Glodecki, C.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2017, 20 (01) : 35 - 51
  • [9] Modular Digital and 3D-Printed Dental Models with Applicability in Dental Education
    Petre, Alexandru Eugen
    Pantea, Mihaela
    Drafta, Sergiu
    Imre, Marina
    Tancu, Ana Maria Cristina
    Liciu, Eduard M.
    Didilescu, Andreea Cristiana
    Pituru, Silviu Mirel
    MEDICINA-LITHUANIA, 2023, 59 (01):
  • [10] Effect of different storage conditions on the fit of 3D-printed occlusal devices used to treat temporomandibular disorders
    Antonopoulou, Stavroula
    Cho, Seok-Hwan
    Kesterke, Matthew
    Kontogiorgos, Elias
    Korentzelos, Dimitrios
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03): : 488.e1 - 488.e9