Scheimpflug photography keratometry readings for routine intraocular lens power calculation

被引:58
|
作者
Shammas, H. John [1 ]
Hoffer, Kenneth J. [2 ]
Shammas, Maya C. [3 ]
机构
[1] Univ So Calif, Keck Sch Med, Dept Ophthalmol, Los Angeles, CA 90089 USA
[2] Univ Calif Los Angeles, Jules Stein Eye Inst, Los Angeles, CA 90024 USA
[3] Cornell Univ, Joan & Sanford I Weill Med Coll, New York, NY 10021 USA
来源
关键词
IN-SITU KERATOMILEUSIS; CORNEAL POWER; ULTRASOUND PACHYMETRY; THICKNESS MEASUREMENT; PENTACAM; ANTERIOR; SURGERY; SYSTEM;
D O I
10.1016/j.jcrs.2008.10.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To prospectively evaluate keratometry (K) values obtained by Scheimpflug photography in eyes scheduled for cataract surgery, compare the results with K values obtained with an autokeratometer (automated K), and evaluate the K values in commonly used intraocular lens (IOL) power calculation formulas for routine cataract surgery. SETTING: Private clinical ophthalmology practice, Lynwood, California, USA. METHODS: The mean simulated K power (simulated K), equivalent K (equivalent K), and true net power (true net K) readings from the Pentacam Comprehensive Eye Scanner were compared with the automated K readings. Automated K, simulated K, and equivalent K values were compared in commonly used IOL power calculation formulas. RESULTS: The mean automated K value was 43.49 diopters (D) +/- 1.75 (SD) and the mean simulated K value, 43.49 +/- 2.00 D (P >.1). The mean equivalent K value was 43.78 +/- 1.97 D and exceeded the mean automated K and simulated K by 0.29 D (P >.1). The mean true net K was 42.31 +/- 2.13 D, which was 1.18 D lower than the automated K and simulated K values (P = .015). The IOL prediction mean absolute error was 0.41 +/- 0.27 D using the automated K method, 0.50 +/- 0.36 D using the simulated K method (difference 0.09 D) (P >.1), and 0.65 +/- 0.35 D using the equivalent K method (difference 0.24 D) (P <.01). CONCLUSION: The K values from Scheimpflug photography did not improve accuracy over autokeratometer values for routine IOL power calculation.
引用
收藏
页码:330 / 334
页数:5
相关论文
共 50 条
  • [41] Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations
    Holladay, JT
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (09): : 1356 - 1370
  • [42] INTRAOCULAR-LENS POWER CALCULATION
    HOPEROSS, M
    MOONEY, D
    EYE, 1988, 2 : 367 - 369
  • [43] CALCULATION OF INTRAOCULAR-LENS POWER
    SUNDERRAJ, P
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (03): : 387 - 388
  • [44] Intraocular lens power calculation in children
    Eibschitz-Tsimhoni, Maya
    Archer, Steven M.
    Del Monte, Monte A.
    SURVEY OF OPHTHALMOLOGY, 2007, 52 (05) : 474 - 482
  • [45] Intraocular lens power calculation software
    Kuchenbecker, J
    Behrens-Baumann, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (05): : 735 - 736
  • [46] Intraocular lens power calculation REPLY
    Jin, Haiying
    Rabsilber, Tanja T.
    Ehmer, Angela
    Borkenstein, Andreas F.
    Limberger, Il-Joo
    Guo, Haike
    Auffarth, Gerd U.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2177 - 2178
  • [47] Intraocular lens power calculation for microphthalmos
    Inatomi, M
    Ishii, K
    Koide, R
    Kora, Y
    Ozawa, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (08): : 1208 - 1212
  • [48] Biometry and intraocular lens power calculation
    Lee, Alexander C.
    Qazi, Mujtaba A.
    Pepose, Jay S.
    CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (01) : 13 - 17
  • [49] Calculation of intraocular lens power: a review
    Olsen, Thomas
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (05): : 472 - 485
  • [50] Intraocular lens power calculations using a Scheimpflug camera to measure corneal power
    Xu, K.
    Hao, Y.
    Qi, H.
    BIOTECHNIC & HISTOCHEMISTRY, 2014, 89 (05) : 348 - 354