Intraocular lens power calculations using a Scheimpflug camera to measure corneal power

被引:10
|
作者
Xu, K. [1 ]
Hao, Y. [1 ]
Qi, H. [1 ]
机构
[1] Peking Univ, Hosp 3, Dept Ophthalmol, Beijing 100871, Peoples R China
关键词
cornea; eyes; IOL calculation; lens; Pentacam; refractive surgery; Scheimpflug camera; IN-SITU KERATOMILEUSIS; MYOPIC PHOTOREFRACTIVE KERATECTOMY; REQUIRING CATARACT-SURGERY; EXCIMER-LASER SURGERY; REFRACTIVE SURGERY; EYES; PENTACAM; FORMULA; PREDICTION;
D O I
10.3109/10520295.2013.867532
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
We measured corneal power using an Oculus Pentacam (R) to assess its accuracy for calculating intraocular lens (IOL) power after myopic refractive surgery. A series of corneal power measurements were performed on 22 patients (43 eyes) who had undergone myopic refractive surgery. In 37 of the 43 eyes, phacoemulsification and IOL implantation subsequently were performed. Conventional keratometry and three corneal measurements (mean true net power, central true net power, and 4.5 mm equivalent K reading) obtained using a Pentacam were analyzed and compared to values derived from the clinical history method. Prediction errors of three Pentacam corneal power measurements inserted in third generation IOL formulas also were compared. Analysis of the variance showed that only two Pentacam corneal measurements, mean true net power and central true net power, were not significantly different from those of the clinical history method. Mean true net power was correlated more closely with the clinical history method corneal power than other corneal power values. The one-sample t-test showed that of three Pentacam corneal measurements combined with third-generation formulas, only the mean true net power inserted in the SRK/T implant power calculation formula was not significantly different from zero. The percentages of eyes within +/- 0.50 D and +/- 1.00 D of the refractive prediction error of this method were 67.6% and 86.5%, respectively. Mean true net power inserted in the SRK/T formula can be used to calculate directly IOL power after myopic refractive surgery.
引用
收藏
页码:348 / 354
页数:7
相关论文
共 50 条
  • [1] Comparison of methods to measure corneal power for intraocular lens power calculation using a rotating Scheimpflug camera
    Savini, Giacomo
    Barboni, Piero
    Carbonelli, Michele
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (04): : 598 - 604
  • [2] Intraocular Lens Power Calculations Using Dual Scheimpflug Analyzer
    Lee, Young Bok
    Yi, Ka Young
    Bae, So Hyun
    Kim, Ha Kyoung
    Hyon, Joon Young
    Wee, Won Ryang
    Shin, Young Joo
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (03): : 369 - 379
  • [3] Accuracy of Scheimpflug corneal power measurements for intraocular lens power calculation
    Savini, Giacomo
    Barboni, Piero
    Carbonelli, Michele
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07): : 1193 - 1197
  • [4] New method for intraocular lens power calculation using a rotating Scheimpflug camera in eyes with corneal refractive surgery
    Kyuyeon Cho
    Dong Hui Lim
    Young-Sik Yoo
    Tae-Young Chung
    Scientific Reports, 10
  • [5] New method for intraocular lens power calculation using a rotating Scheimpflug camera in eyes with corneal refractive surgery
    Cho, Kyuyeon
    Lim, Dong Hui
    Yoo, Young-Sik
    Chung, Tae-Young
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [6] Scheimpflug Corneal Power Measurements for Intraocular Lens Power Calculation in Cataract Surgery
    Saad, Elie
    Shammas, Maya C.
    Shammas, H. John
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (03) : 460 - 467
  • [7] Corneal topography for intraocular lens power calculations
    Alimisi, S
    Miltsakakis, D
    Klyce, S
    JOURNAL OF REFRACTIVE SURGERY, 1996, 12 (02): : S309 - S311
  • [8] Effect of corneal aberrations on intraocular lens power calculations
    Canovas, Carmen
    Abenza, Salome
    Alcon, Encarna
    Villegas, Eloy A.
    Marin, Jose M.
    Artal, Pablo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (08): : 1325 - 1332
  • [9] Scheimpflug camera combined with placido-disk corneal topography and optical biometry for intraocular lens power calculation
    Ahmet Kirgiz
    Kurşat Atalay
    Havva Kaldirim
    Kubra Serefoglu Cabuk
    Mehmet Orcun Akdemir
    Muhittin Taskapili
    International Ophthalmology, 2017, 37 : 781 - 786
  • [10] Scheimpflug camera combined with placido-disk corneal topography and optical biometry for intraocular lens power calculation
    Kirgiz, Ahmet
    Atalay, Kursat
    Kaldirim, Havva
    Cabuk, Kubra Serefoglu
    Akdemir, Mehmet Orcun
    Taskapili, Muhittin
    INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (04) : 781 - 786