Intraocular lens power calculations using a Scheimpflug camera to measure corneal power

被引:10
|
作者
Xu, K. [1 ]
Hao, Y. [1 ]
Qi, H. [1 ]
机构
[1] Peking Univ, Hosp 3, Dept Ophthalmol, Beijing 100871, Peoples R China
关键词
cornea; eyes; IOL calculation; lens; Pentacam; refractive surgery; Scheimpflug camera; IN-SITU KERATOMILEUSIS; MYOPIC PHOTOREFRACTIVE KERATECTOMY; REQUIRING CATARACT-SURGERY; EXCIMER-LASER SURGERY; REFRACTIVE SURGERY; EYES; PENTACAM; FORMULA; PREDICTION;
D O I
10.3109/10520295.2013.867532
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
We measured corneal power using an Oculus Pentacam (R) to assess its accuracy for calculating intraocular lens (IOL) power after myopic refractive surgery. A series of corneal power measurements were performed on 22 patients (43 eyes) who had undergone myopic refractive surgery. In 37 of the 43 eyes, phacoemulsification and IOL implantation subsequently were performed. Conventional keratometry and three corneal measurements (mean true net power, central true net power, and 4.5 mm equivalent K reading) obtained using a Pentacam were analyzed and compared to values derived from the clinical history method. Prediction errors of three Pentacam corneal power measurements inserted in third generation IOL formulas also were compared. Analysis of the variance showed that only two Pentacam corneal measurements, mean true net power and central true net power, were not significantly different from those of the clinical history method. Mean true net power was correlated more closely with the clinical history method corneal power than other corneal power values. The one-sample t-test showed that of three Pentacam corneal measurements combined with third-generation formulas, only the mean true net power inserted in the SRK/T implant power calculation formula was not significantly different from zero. The percentages of eyes within +/- 0.50 D and +/- 1.00 D of the refractive prediction error of this method were 67.6% and 86.5%, respectively. Mean true net power inserted in the SRK/T formula can be used to calculate directly IOL power after myopic refractive surgery.
引用
收藏
页码:348 / 354
页数:7
相关论文
共 50 条
  • [41] The role of the epithelium in intraocular lens and corneal power calculation
    Wendelstein, Jascha A.
    Atchison, David A.
    Gatinel, Damien
    Cooke, David L.
    Langenbucher, Achim
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2025, 45 (02) : 372 - 382
  • [42] Principles of corneal measurement for intraocular lens power calculation
    Findl, Oliver
    Hirnschall, Nino
    EXPERT REVIEW OF OPHTHALMOLOGY, 2016, 11 (02) : 93 - 99
  • [43] Intraocular Lens Power Calculations in Eyes with Previous Corneal Refractive Surgery Review and Expert Opinion
    Wang, Li
    Koch, Douglas D.
    OPHTHALMOLOGY, 2021, 128 (11) : E121 - E131
  • [44] Relationship of corneal asphericity to intraocular lens power calculations after myopic laser in situ keratomileusis
    Mori, Yosai
    Shimizu, Kimiya
    Minami, Keiichiro
    Kamiya, Kazutaka
    Shoji, Nobuyuki
    Miyata, Kazunori
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (05): : 703 - 709
  • [45] Intraocular lens power calculations in eyes with previous corneal refractive surgery: Challenges, approaches, and outcomes
    Wang, Li
    Koch, Douglas
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2022, 12 (01) : 22 - 31
  • [46] Intraocular Lens Power Calculations in a Patient with Posterior Keratoconus
    Park, Do Young
    Lim, Dong Hui
    Chung, Tae-Young
    Chung, Eui-Sang
    CORNEA, 2013, 32 (05) : 708 - 711
  • [47] Preclinical Estimation of Constants for Intraocular Lens Power Calculations
    Simpson, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [48] Preoperative intraocular lens power calculations in problem eyes
    Haigis, Wolfgang
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2007, 17 (01): : 45 - 54
  • [49] Intraocular lens power calculations in eyes with pseudoexfoliation syndrome
    Wlaz, Aleksandra
    Kustra, Agnieszka
    Rozegnal-Madej, Agnieszka
    Zarnowski, Tomasz
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [50] Accuracy of intraocular lens power calculations in paediatric eyes
    Li, Jianbing
    Liu, Zhenzhen
    Wang, Ruixin
    Cheng, Huanhuan
    Zhao, Jing
    Liu, Liangping
    Chen, Weirong
    Wu, Mingxing
    Liu, Yizhi
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 48 (03): : 301 - 310