Intraocular lens power calculations using a Scheimpflug camera to measure corneal power

被引:10
|
作者
Xu, K. [1 ]
Hao, Y. [1 ]
Qi, H. [1 ]
机构
[1] Peking Univ, Hosp 3, Dept Ophthalmol, Beijing 100871, Peoples R China
关键词
cornea; eyes; IOL calculation; lens; Pentacam; refractive surgery; Scheimpflug camera; IN-SITU KERATOMILEUSIS; MYOPIC PHOTOREFRACTIVE KERATECTOMY; REQUIRING CATARACT-SURGERY; EXCIMER-LASER SURGERY; REFRACTIVE SURGERY; EYES; PENTACAM; FORMULA; PREDICTION;
D O I
10.3109/10520295.2013.867532
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
We measured corneal power using an Oculus Pentacam (R) to assess its accuracy for calculating intraocular lens (IOL) power after myopic refractive surgery. A series of corneal power measurements were performed on 22 patients (43 eyes) who had undergone myopic refractive surgery. In 37 of the 43 eyes, phacoemulsification and IOL implantation subsequently were performed. Conventional keratometry and three corneal measurements (mean true net power, central true net power, and 4.5 mm equivalent K reading) obtained using a Pentacam were analyzed and compared to values derived from the clinical history method. Prediction errors of three Pentacam corneal power measurements inserted in third generation IOL formulas also were compared. Analysis of the variance showed that only two Pentacam corneal measurements, mean true net power and central true net power, were not significantly different from those of the clinical history method. Mean true net power was correlated more closely with the clinical history method corneal power than other corneal power values. The one-sample t-test showed that of three Pentacam corneal measurements combined with third-generation formulas, only the mean true net power inserted in the SRK/T implant power calculation formula was not significantly different from zero. The percentages of eyes within +/- 0.50 D and +/- 1.00 D of the refractive prediction error of this method were 67.6% and 86.5%, respectively. Mean true net power inserted in the SRK/T formula can be used to calculate directly IOL power after myopic refractive surgery.
引用
收藏
页码:348 / 354
页数:7
相关论文
共 50 条
  • [32] Intraocular lens power calculation using adjusted corneal power in eyes after myopic corneal refractive surgery
    Tan, Qian
    Lin, Ding
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [33] Use of Scheimpflug corneal anterior-posterior imaging in ray-tracing intraocular lens power calculation
    Miyata, Kazunori
    Otani, Shinichiro
    Honbou, Naoto
    Minami, Keiichiro
    ACTA OPHTHALMOLOGICA, 2013, 91 (07) : E546 - E549
  • [35] INTRAOCULAR-LENS POWER CALCULATIONS FOR MULTIFOCAL INTRAOCULAR LENSES
    HOLLADAY, JT
    HOFFER, KJ
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1992, 114 (04) : 405 - 408
  • [36] Corneal power changes with Scheimpflug rotating camera after hyperopic LASIK
    Whang, Woong-Joo
    Yoo, Young-Sik
    Joo, Choun-Ki
    MEDICINE, 2018, 97 (50)
  • [37] Scheimpflug photography keratometry readings for routine intraocular lens power calculation
    Shammas, H. John
    Hoffer, Kenneth J.
    Shammas, Maya C.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (02): : 330 - 334
  • [38] Paediatric intraocular lens implants: accuracy of lens power calculations
    O'Gallagher, M. K.
    Lagan, M. A.
    Mulholland, C. P.
    Parker, M.
    McGinnity, G.
    McLoone, E. M.
    EYE, 2016, 30 (09) : 1215 - 1220
  • [39] Paediatric intraocular lens implants: accuracy of lens power calculations
    M K O'Gallagher
    M A Lagan
    C P Mulholland
    M Parker
    G McGinnity
    E M McLoone
    Eye, 2016, 30 : 1215 - 1220
  • [40] Intraocular lens power calculations in short eyes using 7 formulas
    Gokce, Sabite E.
    Zeiter, John H.
    Weikert, Mitchell P.
    Koch, Douglas D.
    Hill, Warren
    Wang, Li
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (07): : 892 - 897