Scheimpflug photography keratometry readings for routine intraocular lens power calculation

被引:58
|
作者
Shammas, H. John [1 ]
Hoffer, Kenneth J. [2 ]
Shammas, Maya C. [3 ]
机构
[1] Univ So Calif, Keck Sch Med, Dept Ophthalmol, Los Angeles, CA 90089 USA
[2] Univ Calif Los Angeles, Jules Stein Eye Inst, Los Angeles, CA 90024 USA
[3] Cornell Univ, Joan & Sanford I Weill Med Coll, New York, NY 10021 USA
来源
关键词
IN-SITU KERATOMILEUSIS; CORNEAL POWER; ULTRASOUND PACHYMETRY; THICKNESS MEASUREMENT; PENTACAM; ANTERIOR; SURGERY; SYSTEM;
D O I
10.1016/j.jcrs.2008.10.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To prospectively evaluate keratometry (K) values obtained by Scheimpflug photography in eyes scheduled for cataract surgery, compare the results with K values obtained with an autokeratometer (automated K), and evaluate the K values in commonly used intraocular lens (IOL) power calculation formulas for routine cataract surgery. SETTING: Private clinical ophthalmology practice, Lynwood, California, USA. METHODS: The mean simulated K power (simulated K), equivalent K (equivalent K), and true net power (true net K) readings from the Pentacam Comprehensive Eye Scanner were compared with the automated K readings. Automated K, simulated K, and equivalent K values were compared in commonly used IOL power calculation formulas. RESULTS: The mean automated K value was 43.49 diopters (D) +/- 1.75 (SD) and the mean simulated K value, 43.49 +/- 2.00 D (P >.1). The mean equivalent K value was 43.78 +/- 1.97 D and exceeded the mean automated K and simulated K by 0.29 D (P >.1). The mean true net K was 42.31 +/- 2.13 D, which was 1.18 D lower than the automated K and simulated K values (P = .015). The IOL prediction mean absolute error was 0.41 +/- 0.27 D using the automated K method, 0.50 +/- 0.36 D using the simulated K method (difference 0.09 D) (P >.1), and 0.65 +/- 0.35 D using the equivalent K method (difference 0.24 D) (P <.01). CONCLUSION: The K values from Scheimpflug photography did not improve accuracy over autokeratometer values for routine IOL power calculation.
引用
收藏
页码:330 / 334
页数:5
相关论文
共 50 条
  • [21] Comparison of methods to measure corneal power for intraocular lens power calculation using a rotating Scheimpflug camera
    Savini, Giacomo
    Barboni, Piero
    Carbonelli, Michele
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (04): : 598 - 604
  • [22] Optimized keratometry and total corneal astigmatism for toric intraocular lens calculation
    Savini, Giacomo
    Naeser, Kristian
    Schiano-Lomoriello, Domenico
    Ducoli, Pietro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (09): : 1140 - 1148
  • [23] Scheimpflug imaging to determine intraocular lens power in vivo
    Turner, Stephen J.
    Lee, Edward J. K.
    Hu, Victor
    Hollick, Emma J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (06): : 1041 - 1044
  • [24] Intraocular lens bicylindric power calculation method: Using both flat and steep K readings to improve intraocular lens power prediction
    Calvo-Sanz, Jorge A.
    Ruiz-Alcocer, Javier
    Sanchez-Tena, Miguel A.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (05) : 559 - 565
  • [25] Keratometry, biometry and prediction of intraocular lens power in the equine eye
    McMullen, Richard J., Jr.
    Gilger, Brian C.
    VETERINARY OPHTHALMOLOGY, 2006, 9 (05) : 357 - 360
  • [26] Algorithmic intraocular lens power calculation formula selection by keratometry, anterior chamber depth and axial length
    Kim, Jung Wan
    Eom, Youngsub
    Yoon, Eun Gyu
    Choi, Young
    Song, Jong Suk
    Jeong, Ji Won
    Park, Seh Kwang
    Kim, Hyo Myung
    ACTA OPHTHALMOLOGICA, 2022, 100 (03) : E701 - E709
  • [27] Intraocular lens power calculation
    Olsen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2176 - 2177
  • [28] Accuracy of Scheimpflug Corneal Power Measurements for Intraocular Lens Power Calculation (vol 35, pg 1193, 2009)
    Savini, G.
    Barboni, P.
    Carbonelli, M.
    Hoffer, K. J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (08): : 1483 - 1483
  • [29] Comparison of refractive outcomes using Scheimpflug Holladay equivalent keratometry or IOLMaster 700 keratometry for IOL power calculation
    Mustafa Aksoy
    Leyla Asena
    Sirel Gür Güngör
    Ali Küçüködük
    Ahmet Akman
    International Ophthalmology, 2021, 41 : 2205 - 2212
  • [30] Pupil size and Scheimpflug Holladay equivalent keratometry readings REPLY
    Tang, Qiongyan
    Hoffer, Kenneth J.
    Olson, Michael D.
    Miller, Kevin M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (01): : 184 - 184