Scheimpflug photography keratometry readings for routine intraocular lens power calculation

被引:58
|
作者
Shammas, H. John [1 ]
Hoffer, Kenneth J. [2 ]
Shammas, Maya C. [3 ]
机构
[1] Univ So Calif, Keck Sch Med, Dept Ophthalmol, Los Angeles, CA 90089 USA
[2] Univ Calif Los Angeles, Jules Stein Eye Inst, Los Angeles, CA 90024 USA
[3] Cornell Univ, Joan & Sanford I Weill Med Coll, New York, NY 10021 USA
来源
关键词
IN-SITU KERATOMILEUSIS; CORNEAL POWER; ULTRASOUND PACHYMETRY; THICKNESS MEASUREMENT; PENTACAM; ANTERIOR; SURGERY; SYSTEM;
D O I
10.1016/j.jcrs.2008.10.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To prospectively evaluate keratometry (K) values obtained by Scheimpflug photography in eyes scheduled for cataract surgery, compare the results with K values obtained with an autokeratometer (automated K), and evaluate the K values in commonly used intraocular lens (IOL) power calculation formulas for routine cataract surgery. SETTING: Private clinical ophthalmology practice, Lynwood, California, USA. METHODS: The mean simulated K power (simulated K), equivalent K (equivalent K), and true net power (true net K) readings from the Pentacam Comprehensive Eye Scanner were compared with the automated K readings. Automated K, simulated K, and equivalent K values were compared in commonly used IOL power calculation formulas. RESULTS: The mean automated K value was 43.49 diopters (D) +/- 1.75 (SD) and the mean simulated K value, 43.49 +/- 2.00 D (P >.1). The mean equivalent K value was 43.78 +/- 1.97 D and exceeded the mean automated K and simulated K by 0.29 D (P >.1). The mean true net K was 42.31 +/- 2.13 D, which was 1.18 D lower than the automated K and simulated K values (P = .015). The IOL prediction mean absolute error was 0.41 +/- 0.27 D using the automated K method, 0.50 +/- 0.36 D using the simulated K method (difference 0.09 D) (P >.1), and 0.65 +/- 0.35 D using the equivalent K method (difference 0.24 D) (P <.01). CONCLUSION: The K values from Scheimpflug photography did not improve accuracy over autokeratometer values for routine IOL power calculation.
引用
收藏
页码:330 / 334
页数:5
相关论文
共 50 条
  • [31] Comparison of refractive outcomes using Scheimpflug Holladay equivalent keratometry or IOLMaster 700 keratometry for IOL power calculation
    Aksoy, Mustafa
    Asena, Leyla
    Gungor, Sirel Gur
    Kucukoduk, Ali
    Akman, Ahmet
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (06) : 2205 - 2212
  • [32] Intraocular lens power calculation for lens exchange
    Kora, Y
    Shimizu, K
    Yoshida, M
    Inatomi, M
    Ozawa, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (04): : 543 - 548
  • [33] Intraocular Lens Power Calculations in Keratoconus Eyes Comparing Keratometry, Total Keratometry, and Newer Formulae
    Heath, Michael T.
    Mulpuri, Lakshman
    Kimiagarov, Eden
    Patel, Raj P.
    Murphy, David A.
    Levine, Harry
    Tonk, Rahul S.
    Cooke, David L.
    Riaz, Kamran M.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 253 : 206 - 214
  • [34] Intraocular Lens Power Calculations Using Dual Scheimpflug Analyzer
    Lee, Young Bok
    Yi, Ka Young
    Bae, So Hyun
    Kim, Ha Kyoung
    Hyon, Joon Young
    Wee, Won Ryang
    Shin, Young Joo
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (03): : 369 - 379
  • [35] Keratometry, ultrasonic biometry, and prediction of intraocular lens power in the feline eye
    Gilger, BC
    Davidson, MG
    Howard, PB
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1998, 59 (02) : 131 - 134
  • [36] Accuracy of Traditional and Modern Formulas for Intraocular Lens Power Calculation After Radial Keratotomy Using Standard Keratometry
    Helaly, Hany Ahmed
    Elhady, Amr Mohamed
    Elnaggar, Osama Ramadan
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 2589 - 2597
  • [37] Accuracy of a dual Scheimpflug analyzer and a corneal topography system for intraocular lens power calculation in unoperated eyes
    Savini, Giacomo
    Barboni, Piero
    Carbonelli, Michele
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (01): : 72 - 76
  • [38] Accuracy of Intraocular Lens Power Calculations Based on Total and Standard Keratometry
    Park, Se Young
    Choi, Jin Seok
    Pak, Kyu Hong
    Chung, Sung Kun
    Kwag, Joo Young
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (11): : 1265 - 1272
  • [39] Prediction Accuracy of Total Keratometry Compared to Standard Keratometry Using Different Intraocular Lens Power Formulas
    Fabian, Ekkehard
    Wehner, Wolfram
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (06) : 362 - 369
  • [40] Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery
    Wang, Li
    Spektor, Tatyana
    de Souza, Rodrigo G.
    Koch, Douglas D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10): : 1416 - 1421