Comparison of corneal power, corneal astigmatism, and axis location in normal eyes obtained from an autokeratometer and a corneal topographer

被引:45
|
作者
Kobashi, Hidenaga [1 ]
Kamiya, Kazutaka
Igarashi, Akihito
Ishii, Rie
Sato, Nobuyuki
Wang, Guoqin [2 ]
Shimizu, Kimiya
机构
[1] Kitasato Univ, Sch Med, Dept Ophthalmol, Minami Ku, Sagamihara, Kanagawa 2288555, Japan
[2] Kitasato Univ, Sch Med, Kitasato Clin Res Ctr, Sagamihara, Kanagawa 2288555, Japan
来源
关键词
ANTERIOR-CHAMBER DEPTH; CATARACT-SURGERY; INTRAOCULAR-LENS; KERATOMETRY; INCISIONS; BIOMETRY; VIDEOKERATOGRAPHY; KERATOTOMY; PREVALENCE; ACCURACY;
D O I
10.1016/j.jcrs.2011.11.026
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the repeatability and agreement of corneal power, corneal astigmatism, axis location, and astigmatic vector component measurements using an autokeratometer and a corneal topographer in healthy subjects. SETTING: Department of Ophthalmology, Kitasato University, Kanagawa, Japan. DESIGN: Evaluation of diagnostic test or technology. METHODS: Keratometric readings were obtained with an ARK-700A autokeratometer and an Atlas corneal topographer. Measurement repeatability and agreement in corneal power (flattest and steepest meridians), mean corneal power, corneal astigmatism, axis location, and astigmatic vector components (Jackson cross-cylinders J0, J45) between the devices were evaluated. RESULTS: The repeatability of both devices in the flattest and steepest meridians, mean corneal power, corneal astigmatism, axis location, J0, and J45 was high. The 95% limits of agreement between the 2 devices were from -0.51 to 0.48 diopters (D) for the flattest meridian, from -0.74 to 0.71 D for the steepest meridian, from -0.56 to 0.53 D for the mean corneal power, from -0.58 to 0.58 D for corneal astigmatism, from -15.3 to 17.5 degrees for axis location, from -0.32 to 0.30 D for J0, and from -0.22 to 0.20 D for J45. In eyes with a small amount of astigmatism, there was wider disagreement in axis location between the 2 devices. CONCLUSIONS: Both devices provided excellent repeatability and comparability of corneal powers and corneal astigmatism, suggesting they can be used interchangeably for measurement of these corneal variables in healthy eyes. However, disagreement in axis location between the 2 devices was not negligible in some eyes, especially in those with low astigmatism.
引用
收藏
页码:648 / 654
页数:7
相关论文
共 50 条
  • [21] Repeatability and Agreement of 4 Biometers Measuring Corneal Astigmatism in Eyes With Irregular Corneal Astigmatism Component
    Wang, Lan
    Shao, Xu
    Fu, Jin-Ling
    Hu, Jing-Jing
    Zhou, Kai-Jing
    Li, Ran
    Yu, A-Yong
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 265 : 200 - 212
  • [22] Comparison of Corneal Epithelial and Stromal Thickness Distributions between Eyes with Keratoconus and Healthy Eyes with Corneal Astigmatism ≥2.0 D
    Zhou, Wen
    Stojanovic, Aleksandar
    PLOS ONE, 2014, 9 (01):
  • [23] Surgically induced astigmatism after phacoemulsification in eyes with mild to moderate corneal astigmatism - Temporal versus on-axis clear corneal incisions
    Borasio, E
    Mehta, JS
    Maurino, V
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (04): : 565 - 572
  • [24] Corneal Topographic Astigmatism Based on Total Corneal Power Data (CorT Total): A Benchmark for Total Corneal Astigmatism
    Alpins, Noel
    Ong, James K. Y.
    Randleman, J. Bradley
    Nevyas-Wallace, Anita
    Stamatelatos, George
    CORNEA, 2020, 39 (04) : 431 - 436
  • [25] Comparison of Corneal Power and Corneal Astigmatism of Different Diameter Zones Centered on the Pupil and Corneal Apex Using Scheimpflug Tomography
    Dong, Jing
    Zhang, Yaqin
    Zhou, Jing
    Zhang, Suhua
    Sun, Bin
    Tang, Maolong
    Wang, Xiaogang
    CORNEA, 2020, 39 (01) : 77 - 83
  • [26] Improving corneal astigmatism measures for keratoconic eyes
    Alpins, Noel
    Ong, James K. Y.
    Stamatelatos, George
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 946 - 946
  • [27] Accuracy of Total Corneal Astigmatism Measurements With a Scheimpflug Imager and a Color Light-Emitting Diode Corneal Topographer
    Klijn, Stijn
    Reus, Nicolaas J.
    van der Sommen, Charlotte M.
    Sicam, Victor Arni D. P.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 167 : 72 - 78
  • [28] Importance of Posterior Corneal Astigmatism in Eyes with Keratoconus
    Moshirfar, Majid
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2018, 13 (01) : 1 - 2
  • [29] Comparison of Multicolored Spot Reflection Topographer and Scheimpflug-Placido System in Corneal Power and Astigmatism Measurements With Normal and Post-refractive Patients
    Lu, Weicong
    Miao, Yaxin
    Li, Yue
    Hu, Xiuli
    Hu, Qingjie
    Huang, Jinhai
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (06) : 370 - +
  • [30] Estimating Total Corneal Astigmatism From Anterior Corneal Data
    Naeser, Kristian
    Savini, Giacomo
    Bregnhoj, Jesper Flethoj
    CORNEA, 2017, 36 (07) : 828 - 833