Corneal Topographic Astigmatism Based on Total Corneal Power Data (CorT Total): A Benchmark for Total Corneal Astigmatism

被引:5
|
作者
Alpins, Noel [1 ,2 ]
Ong, James K. Y. [3 ]
Randleman, J. Bradley [4 ]
Nevyas-Wallace, Anita [5 ]
Stamatelatos, George [1 ]
机构
[1] NewVis Clin, Melbourne, Vic, Australia
[2] Univ Melbourne, Dept Ophthalmol, Melbourne, Vic, Australia
[3] ASSORT Pty Ltd, Melbourne, Vic, Australia
[4] Cleveland Clin Fdn, Cole Eye Inst, 9500 Euclid Ave, Cleveland, OH 44195 USA
[5] Nevyas Eye Associates, Delaware Valley Laser Surg Inst, Philadelphia, PA USA
关键词
corneal topographic astigmatism (CorT); corneal tomography; total corneal power; IN-SITU KERATOMILEUSIS; LIGHT-REFLEX; REFRACTIVE ASTIGMATISM; ORBSCAN-II; SURGERY; CENTRATION; AGREEMENT; ABLATION; OUTCOMES; VERTEX;
D O I
10.1097/ICO.0000000000002162
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate how closely manufacturer-provided measures of total corneal astigmatism correspond with the manifest refractive cylinder, as compared to a benchmark of corneal topographic astigmatism calculated on the basis of measured total corneal power (TCP) data (CorT Total). Methods: The SD of the ocular residual astigmatism magnitude (ORAsd) was evaluated for normal virgin eyes based on an optimized benchmark CorT Total and the various measures of total corneal astigmatism provided by 3 different Scheimpflug tomographers. Results: The CorT Total corresponded with the manifest refractive cylinder at least as well as all the measures of total corneal astigmatism provided by the tomographers [Sirius CorT Total ORAsd: 0.320D (standard error [SE] 0.017D), Sirius TCP 4 mm ORAsd: 0.324D (SE 0.017D); Pentacam CorT Total ORAsd: 0.338D (SE 0.027D), Pentacam total corneal refractive power apex zone 4 mm ORAsd: 0.337D (SE 0.029D); Galilei CorT Total ORAsd: 0.472D (SE 0.068D), and Galilei TCP2 ORAsd: 0.536D (SE 0.124D)]. The difference between CorT Total and best measure on each tomographer was not statistically significant (Sirius TCP 4 mm: P = 0.24, Pentacam total corneal refractive power apex zone 4 mm: P = 0.64, Galilei TCP2: P = 0.24). Most of the manufacturer-provided measures did not correspond closely with the manifest refractive cylinder. When there were multiple measures of total corneal astigmatism, those derived from a zone with a diameter of 4.0 mm corresponded best with the manifest refractive cylinder. Conclusions: The CorT Total is a reliable benchmark measure that can be used to assess how well other measures of total corneal astigmatism correspond with the manifest refractive cylinder.
引用
收藏
页码:431 / 436
页数:6
相关论文
共 50 条
  • [1] CORNEAL TOPOGRAPHIC ASTIGMATISM (CORT) AND TOTAL CORNEAL POWER
    Alpins, Noel
    Stamatelatos, George
    Ong, James
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 : 64 - 64
  • [2] Corneal Topographic Astigmatism (CorT) to Quantify Total Corneal Astigmatism
    Alpins, Noel
    Ong, James K. Y.
    Stamatelatos, George
    JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (03) : 182 - U110
  • [3] ACCURACY OF TOTAL CORNEAL TOPOGRAPHIC ASTIGMATISM (CORT TOTAL) COMPARED TO THE TOTAL CORNEAL POWER MEASURED USING 3 DIFFERENT YOMOGRAPHERS
    Alpins, Noel A. M.
    Randleman, Bradley
    Neyvas-Wallce, Anita
    Ong, James
    Stamatelatos, George
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 : 51 - 51
  • [4] Accuracy of total corneal topographic astigmatism (CORT total) compared to total keratometry (TK)
    Alpins, Noel
    Ong, James
    Stamatelatos, George
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 47 : 45 - 45
  • [5] Quantifying Corneal Topographic Astigmatism (CorT Total) in Keratoconic Eyes
    Alpins, Noel
    Ong, James K. Y.
    Randleman, J. Bradley
    Stamatelatos, George
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (03) : 206 - +
  • [6] Contribution of posterior corneal astigmatism to total corneal astigmatism
    Koch, Douglas D.
    Ali, Shazia F.
    Weikert, Mitchell P.
    Shirayama, Mariko
    Jenkins, Richard
    Wang, Li
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12): : 2080 - 2087
  • [7] Estimating Total Corneal Astigmatism From Anterior Corneal Data
    Naeser, Kristian
    Savini, Giacomo
    Bregnhoj, Jesper Flethoj
    CORNEA, 2017, 36 (07) : 828 - 833
  • [8] Total Corneal Astigmatism Measurement
    Galvis, Virgilio
    Tello, Alejandro
    Nino, Camilo A.
    Parra, Maria Margarita
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (09) : 5269 - 5270
  • [9] Influence of Posterior Corneal Astigmatism on Total Corneal Astigmatism in Eyes With Keratoconus
    Savini, Giacomo
    Naeser, Kristian
    Schiano-Lomoriello, Domenico
    Mularoni, Alessandro
    CORNEA, 2016, 35 (11) : 1427 - 1433
  • [10] Influence of posterior corneal astigmatism on total corneal astigmatism in eyes with moderate to high astigmatism
    Savini, Giacomo
    Versaci, Francesco
    Vestri, Gabriele
    Ducoli, Pietro
    Naeser, Kristian
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (10): : 1645 - 1653