Corneal Topographic Astigmatism Based on Total Corneal Power Data (CorT Total): A Benchmark for Total Corneal Astigmatism

被引:5
|
作者
Alpins, Noel [1 ,2 ]
Ong, James K. Y. [3 ]
Randleman, J. Bradley [4 ]
Nevyas-Wallace, Anita [5 ]
Stamatelatos, George [1 ]
机构
[1] NewVis Clin, Melbourne, Vic, Australia
[2] Univ Melbourne, Dept Ophthalmol, Melbourne, Vic, Australia
[3] ASSORT Pty Ltd, Melbourne, Vic, Australia
[4] Cleveland Clin Fdn, Cole Eye Inst, 9500 Euclid Ave, Cleveland, OH 44195 USA
[5] Nevyas Eye Associates, Delaware Valley Laser Surg Inst, Philadelphia, PA USA
关键词
corneal topographic astigmatism (CorT); corneal tomography; total corneal power; IN-SITU KERATOMILEUSIS; LIGHT-REFLEX; REFRACTIVE ASTIGMATISM; ORBSCAN-II; SURGERY; CENTRATION; AGREEMENT; ABLATION; OUTCOMES; VERTEX;
D O I
10.1097/ICO.0000000000002162
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate how closely manufacturer-provided measures of total corneal astigmatism correspond with the manifest refractive cylinder, as compared to a benchmark of corneal topographic astigmatism calculated on the basis of measured total corneal power (TCP) data (CorT Total). Methods: The SD of the ocular residual astigmatism magnitude (ORAsd) was evaluated for normal virgin eyes based on an optimized benchmark CorT Total and the various measures of total corneal astigmatism provided by 3 different Scheimpflug tomographers. Results: The CorT Total corresponded with the manifest refractive cylinder at least as well as all the measures of total corneal astigmatism provided by the tomographers [Sirius CorT Total ORAsd: 0.320D (standard error [SE] 0.017D), Sirius TCP 4 mm ORAsd: 0.324D (SE 0.017D); Pentacam CorT Total ORAsd: 0.338D (SE 0.027D), Pentacam total corneal refractive power apex zone 4 mm ORAsd: 0.337D (SE 0.029D); Galilei CorT Total ORAsd: 0.472D (SE 0.068D), and Galilei TCP2 ORAsd: 0.536D (SE 0.124D)]. The difference between CorT Total and best measure on each tomographer was not statistically significant (Sirius TCP 4 mm: P = 0.24, Pentacam total corneal refractive power apex zone 4 mm: P = 0.64, Galilei TCP2: P = 0.24). Most of the manufacturer-provided measures did not correspond closely with the manifest refractive cylinder. When there were multiple measures of total corneal astigmatism, those derived from a zone with a diameter of 4.0 mm corresponded best with the manifest refractive cylinder. Conclusions: The CorT Total is a reliable benchmark measure that can be used to assess how well other measures of total corneal astigmatism correspond with the manifest refractive cylinder.
引用
收藏
页码:431 / 436
页数:6
相关论文
共 50 条
  • [21] Assessing Total Keratometry Astigmatism, Simulated Keratometry, and Total Corneal Topographic Astigmatism Against Manifest Refractive Cylinder
    Alpins, Noel
    Ong, James K. Y.
    Stamatelatos, George
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (03) : 198 - 201
  • [22] Impact of corneal thickness and posterior corneal curvature on total corneal astigmatism.
    Tonn, Bastian
    Kohnen, Thomas
    Klaproth, Oliver
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [23] The effect of posterior corneal flat meridian and astigmatism amount on the total corneal astigmatism estimated from anterior corneal measurements
    Eom, Youngsub
    Kang, Su-Yeon
    Kim, Hyo Myung
    Song, Jong Suk
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (11) : 1769 - 1777
  • [24] 5. CORNEAL TOPOGRAPHIC ASTIGMATISM (CORT) - AN ACCURATE MEASURE OF CORNEAL ASTIGMATISM FOR TORIC IOLS AND REFRACTIVE TREATMENTS
    Alpins, Noel
    Stamatelatos, George
    Ong, James
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 44 : 68 - 69
  • [25] The effect of posterior corneal flat meridian and astigmatism amount on the total corneal astigmatism estimated from anterior corneal measurements
    Youngsub Eom
    Su-Yeon Kang
    Hyo Myung Kim
    Jong Suk Song
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 1769 - 1777
  • [26] A New Approach for the Calculation of Total Corneal Astigmatism Considering the Magnitude and Orientation of Posterior Corneal Astigmatism and Thickness
    Pinero, David P.
    Caballero, Maria T.
    Nicolas-Albujer, Juan M.
    de Fez, Dolores
    Camps, Vicent J.
    CORNEA, 2018, 37 (06) : 720 - 726
  • [27] Corneal and lenticular components of total astigmatism in a preschool sample
    Shankar, S
    Bobier, WR
    OPTOMETRY AND VISION SCIENCE, 2004, 81 (07) : 536 - 542
  • [28] Author Response: Total Corneal Astigmatism Measurement Precision
    Savini, Giacomo
    Naeser, Kristian
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (10) : 5913 - 5913
  • [29] Comparison of Total Corneal Astigmatism between IOLMaster and Pentacam
    Li, Xiaochun
    Cao, Xiaoguang
    Bao, Yongzhen
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [30] DIFFERENCES IN OCULAR RESIDUAL ASTIGMATISM FOR MEASUREMENTS OF ANTERIOR AND TOTAL CORNEAL POWER
    Greenwell, Timothy
    Zamora-Alejo, Katherine
    Athanasiov, Paul
    Goggin, Michael
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 : 55 - 56