Comparison of corneal power, corneal astigmatism, and axis location in normal eyes obtained from an autokeratometer and a corneal topographer

被引:45
|
作者
Kobashi, Hidenaga [1 ]
Kamiya, Kazutaka
Igarashi, Akihito
Ishii, Rie
Sato, Nobuyuki
Wang, Guoqin [2 ]
Shimizu, Kimiya
机构
[1] Kitasato Univ, Sch Med, Dept Ophthalmol, Minami Ku, Sagamihara, Kanagawa 2288555, Japan
[2] Kitasato Univ, Sch Med, Kitasato Clin Res Ctr, Sagamihara, Kanagawa 2288555, Japan
来源
关键词
ANTERIOR-CHAMBER DEPTH; CATARACT-SURGERY; INTRAOCULAR-LENS; KERATOMETRY; INCISIONS; BIOMETRY; VIDEOKERATOGRAPHY; KERATOTOMY; PREVALENCE; ACCURACY;
D O I
10.1016/j.jcrs.2011.11.026
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the repeatability and agreement of corneal power, corneal astigmatism, axis location, and astigmatic vector component measurements using an autokeratometer and a corneal topographer in healthy subjects. SETTING: Department of Ophthalmology, Kitasato University, Kanagawa, Japan. DESIGN: Evaluation of diagnostic test or technology. METHODS: Keratometric readings were obtained with an ARK-700A autokeratometer and an Atlas corneal topographer. Measurement repeatability and agreement in corneal power (flattest and steepest meridians), mean corneal power, corneal astigmatism, axis location, and astigmatic vector components (Jackson cross-cylinders J0, J45) between the devices were evaluated. RESULTS: The repeatability of both devices in the flattest and steepest meridians, mean corneal power, corneal astigmatism, axis location, J0, and J45 was high. The 95% limits of agreement between the 2 devices were from -0.51 to 0.48 diopters (D) for the flattest meridian, from -0.74 to 0.71 D for the steepest meridian, from -0.56 to 0.53 D for the mean corneal power, from -0.58 to 0.58 D for corneal astigmatism, from -15.3 to 17.5 degrees for axis location, from -0.32 to 0.30 D for J0, and from -0.22 to 0.20 D for J45. In eyes with a small amount of astigmatism, there was wider disagreement in axis location between the 2 devices. CONCLUSIONS: Both devices provided excellent repeatability and comparability of corneal powers and corneal astigmatism, suggesting they can be used interchangeably for measurement of these corneal variables in healthy eyes. However, disagreement in axis location between the 2 devices was not negligible in some eyes, especially in those with low astigmatism.
引用
收藏
页码:648 / 654
页数:7
相关论文
共 50 条
  • [41] Increase of axial length in eyes with high corneal astigmatism
    Enthoven, C. A.
    Tideman, J. W. L.
    Polling, J. R.
    Verhoeven, V. J. M.
    Klaver, C. C. W.
    ACTA OPHTHALMOLOGICA, 2017, 95 : 11 - 12
  • [42] Agreement Between Refractive and Corneal Astigmatism in Pseudophakic Eyes
    Tejedor, Jaime
    Guirao, Antonio
    CORNEA, 2013, 32 (06) : 783 - 790
  • [43] CORNEAL ASTIGMATISM AFTER CATARACT-EXTRACTION - COMPARISON OF CORNEAL AND CORNEOSCLERAL INCISIONS
    THYGESEN, J
    REERSTED, P
    FLEDELIUS, H
    CORYDON, L
    ACTA OPHTHALMOLOGICA, 1979, 57 (02): : 243 - 251
  • [44] Distribution of Anterior and Posterior Corneal Astigmatism in Eyes With Keratoconus
    Naderan, Mohammad
    Rajabi, Mohammad Taher
    Zarrinbakhsh, Parviz
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 167 : 79 - 87
  • [45] Agreement Between Internal Astigmatism and Posterior Corneal Astigmatism in Pseudophakic Eyes
    Feizi, Sepehr
    Delfazayebaher, Siamak
    Javadi, Mohammad Ali
    JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (06) : 379 - +
  • [46] Clinical evaluation of oculus keratograph corneal topographer in normal population
    Ehsaei, A.
    Yazdani, N.
    Moghadam, H. Ostadi
    Shahkarami, L.
    ACTA OPHTHALMOLOGICA, 2016, 94
  • [47] CORNEAL AUTOFLUORESCENCE IN DIABETIC AND NORMAL EYES
    FANTAGUZZI, S
    DOCCHIO, F
    GUARISCO, L
    BRANCATO, R
    INTERNATIONAL OPHTHALMOLOGY, 1994, 18 (04) : 211 - 214
  • [48] Corneal Enantiomorphism in Normal and Keratoconic Eyes
    Saad, Alain
    Guilbert, Emmanuel
    Gatinel, Damien
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (08) : 542 - 548
  • [49] The Combined Effect of Tropicamide and Phenylephrine on Corneal Astigmatism Axis
    Sanchez-Gonzalez, Jose-Maria
    Flikier, David
    Nebro-Cobos, Salvador
    Zamorano-Martin, Francisco
    Rachwani-Anil, Rahul
    Garcia-Lorente, Maria
    Borroni, Davide
    Peraza-Nieves, Jorge
    Rocha-de-Lossada, Carlos
    CURRENT EYE RESEARCH, 2022, 47 (02) : 179 - 186
  • [50] Quantitative comparison of corneal surface areas in keratoconus and normal eyes
    Crahay, Francois-Xavier
    Debellemaniere, Guillaume
    Tobalem, Stephan
    Ghazal, Wassim
    Moran, Sarah
    Gatinel, Damien
    SCIENTIFIC REPORTS, 2021, 11 (01)